10
D) Enable the option by following the instructions
below:
EXIT
SYSTEM ENTER
PRINT CONTROL
TEST
MENU
READY
STOP
ERROR
PRINTER OPTIONS
USER MENU
SYSTEM SETTINGS
MEDIA SETTINGS
Control Panel
Step
Instruction
Displayed Message
a
Press the MENU Button on the Control Panel.
USER MENU
MEDIA SETTINGS
b
Using the DOWN Button, scroll to PRINTER
OPTIONS and press the ENTER Key.
PRINTER OPTIONS
MODULES
c
Scroll to RFID and press ENTER.
RFID
RFID MODULE
d
Press ENTER.
RFID MODULE
DISABLED
e
Scroll to the installed module type and press ENTER.
RFID
RFID MODULE
f
Press the EXIT Key, and then the YES Key.
(A reset will occur then, following initialization, the
RFID Indicator will appear.)
Note: If an RFID FAULT occurs, ensure that the
correct module has been selected. If the
fault continues, recheck the installation.
READY
RFID
This completes installation. Refer to the RFID Quick Start Guide to begin using the option.