background image

  

HF Option: 

G) Place the Washer (Item 

11) and then the Long 
Spacer
 (Item 10) onto the 
Screw (Item 8). Place a 
Short Spacer (Item 9) 
over the Long Spacer and 
Screw. Insert the Long 
Spacer
 and Screw 
through the HF Module 
(Item 14). Place a Short 
Spacer
 (Item 9) over the 
Long Spacer and Screw 
then secure the assembled 
parts to the Mounting 
Plate
, as shown.   

  

 

Short

Spacer

Mounting

Plate

Screw

Short

Spacer

Long

Spacer

HF

Module

Washer

 

 

 

 

 
 

 

 
 
H)
 Affix the FCC Label (Item 

13) to the Mounting 
Plate. 
Route the Antenna 
Cable
 behind the 
Mounting Plate and then 
connect the cables 
according to the table 
below:  

  

 

Regulator

CCA

Mounting

Plate

Power

Supply CCA

J1

Main Logic

CCA

Antenna

Port

J2

J3

I/O

J12

J7

Antenna

Cable

HF

Module

FCC Label

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable  

From 

To 

Antenna Cable 

Antenna 

Antenna Port – HF Module 

Power Cable (Item 4) 

J7 – Power Supply CCA 

J1 - Regulator CCA 

Comm Cable (Item 5) 

J12  Main Logic CCA 

J2 – Regulator CCA 

 

I/O  

HF Module 

J3 – Regulator CCA  

 

 

Summary of Contents for datamax-o'neil M-4206

Page 1: ...RFID Ready Option 92 2499 01 Rev C ...

Page 2: ......

Page 3: ...evice must accept any interference including interference that may cause undesired operation of this device For your safety and to avoid equipment damage always turn OFF power and unplug the printer s power cord before beginning this installation and when performing service CAUTION To avoid equipment damage never apply power to the printer with the Antenna Cable disconnected Note This equipment ha...

Page 4: ... Short Spacer 2 34 X 31 10 Long Spacer 25 X 62 11 Washer 12 RF Shield 13 FCC Label 14 HF Module 3 2 4 5 1 13 8 11 10 9 7 6 12 14 UHF Option 1 Antenna 2 Regulator CCA 3 Mounting Plate 4 Power Cable 5 Communications Cable 6 Screw 3 M4 x 8 7 Double Sided Tape 8 Screw 4 M3 x 6 9 I O Cable 10 UHF Module 11 Standoff 4 M3x13 3 1 2 4 5 6 7 8 10 9 11 Also included but not shown is the RFID Quick Start Guid...

Page 5: ...d a new version Follow the Updating Firmware instructions in the Operator s Manual and install the update FORMAT ATTRIBUTES l XOR LABEL ROTATION DISABLED IMAGING MODE MULTIPLE LABEL PAUSE MODE DISABLED PEEL MODE DISABLED SECURITY DISABLED UNITS OF MEASURE IMPERIAL INPUT MODE DPL CONFIGURATION THU 09 09 AM 24APR2008 PRINTER KEY 4210 MG10 071010 027 APPLICATION VERSION 83 2625 10H 10 07 07 24 2007 B...

Page 6: ...r Screws on the Centerplate then remove the Cover Cover Screws Cover Centerplate D Remove the Fascia Thumbscrew and Tearbar or other output attachment Press the Printhead Latch and then raise the Printhead Assembly Remove media from the printer Printhead Assembly Thumbscrew Tearbar Fascia Printhead Latch ...

Page 7: ...Peel the backing from the RF Shield Item 12 Affix the RF Shield to the Antenna Item 1 in the area as shown right RF Sheild HF Option only Antenna C According to the option type cut the tape over the HF Opening or UHF Opening in the Antenna Mount Route the Antenna Cable through the opening If installing the HF Option orient the RF Shield over the UHF Opening Affix the Antenna Item 1 in the Antenna ...

Page 8: ...ng Plate Item 3 underneath Secure the Mounting Plate to the Centerplate using the Screw Item 6 and then tighten the Guide Screw and the Heat Sink Screw Screw Mounting Plate Centerplate Notched Tab Notched Tab Heat Sink Screw Guide Screw F Secure the Regulator CCA Item 2 to the Mounting Plate using the Screws Item 6 then proceed according to the option type Mounting Plate Regulator CCA Screws ...

Page 9: ...r Mounting Plate Screw Short Spacer Long Spacer HF Module Washer H Affix the FCC Label Item 13 to the Mounting Plate Route the Antenna Cable behind the Mounting Plate and then connect the cables according to the table below Regulator CCA Mounting Plate Power Supply CCA J1 Main Logic CCA Antenna Port J2 J3 I O J12 J7 Antenna Cable HF Module FCC Label Cable From To Antenna Cable Antenna Antenna Port...

Page 10: ...ting Plate and then connect the cables according to the table below Mounting Plate Regulator CCA Power Supply CCA J1 J12 Main Logic CCA J2 J7 Antenna Port Antenna Cable UHF Module J3 J1 J2 Cable From To Antenna Cable Antenna Antenna Port J1 UHF Module Power Cable Item 4 J7 Power Supply CCA J1 Regulator CCA Comm Cable Item 5 J12 Main Logic CCA J2 Regulator CCA I O Cable Item 9 J2 UHF Module J3 Regu...

Page 11: ...ead Assembly Replace the Cover Reinstall and tighten the three Cover Screws Cover Screws B Replace the Tearbar and Thumbscrew or other output attachment Replace the Fascia Tighten the Cover Screws on the Centerplate Cover Screws Centerplate C Plug the power cord into the AC Receptacle and turn ON the Power Switch Power Switch AC Receptacle ...

Page 12: ... press the ENTER Key PRINTER OPTIONS MODULES c Scroll to RFID and press ENTER RFID RFID MODULE d Press ENTER RFID MODULE DISABLED e Scroll to the installed module type and press ENTER RFID RFID MODULE f Press the EXIT Key and then the YES Key A reset will occur then following initialization the RFID Indicator will appear Note If an RFID FAULT occurs ensure that the correct module has been selected...

Reviews: