CTK04 ComfortNet™ Communicating Thermostat
21
I/O-CHTSTAT03 69-2688—11
Alerts Log
MENU > INSTALLER OPTIONS > DATA LOGS > ALERTS LOG
The thermostat saves the most recent 25 alerts. It records the date, time, alert status
(snoozed, dismissed, recovered), and diagnostic information to help you identify and
correct problems.
User Interactions Log
MENU > INSTALLER OPTIONS > DATA LOGS > USER INTERACTIONS LOG
Check this log to find out if a problem was caused by an accidental user error.
The log shows most changes made to thermostat settings, by time and date, and
describes what change was made.
The thermostat records the most recent 250 changes. You can quickly search them
by date and time, or by function. This feature can be turned off if necessary, so that
no user interactions are recorded.
Examples:
*
[date, time]
Heat temperature set to 80° F
*
[date, time]
System mode set to Off
*
[date, time]
Installer setup changed — heating equipment type
Replacing system components
Follow steps below to disconnect the thermostat and RedLINK accessories.
To replace a thermostat
At the Portable Comfort Control
1 Press and hold the blank space (or arrow if present)
in the lower right hand corner of the screen until the
display changes.
2 Press
REMOVE
, then
YES
to disconnect from the old
thermostat.
At the Indoor Sensor, Entry/Exit Remote, Vent Boost Remote, RedLINK Internet
Gateway or TrueSTEAM Wireless Adapter
1 Press and hold the
CONNECT
button on the RedLINK accessory until the status
light glows amber (hold for about 10 seconds). This will disconnect the device
from the old thermostat.
Re-connect RedLINK accessories
1 Follow the steps in “Link optional accessories to wireless network” on page 9.
MCR32958
Press and hold
in lower right
corner of screen