69-2688—11 I/O-CHTSTAT03
Installer options (ISU)
6
Create Setup:
Press
CREATE SETUP
to set all system settings one
by one.
View/Edit Current Setup:
Press
VIEW/EDIT CURRENT SETUP
to
select a specific function and make quick changes.
Installer Test:
Press
INSTALLER TEST
to quickly determine if the
heat, cool, fan and thermostat are operating properly. Minimum off
timers are ignored during the test.
Data Logs:
Press
DATA LOGS
to view the Alerts Log and User
Interactions Log.
Wireless Device Manager:
Press
WIRELESS DEVICE MANAGER
to add or remove wireless accessories.
Advanced Options:
Press
ADVANCED OPTIONS
to setup the
thermostat using a USB device or to restore the thermostat to the
factory default settings. See page 2 for more information on the USB
port.
TIP
: You can use the thermostat USB port to download all system configuration and installer options, including your company
name and contact information. You can upload this data to each thermostat you install, to save time.
To setup the thermostat, press
MENU
and scroll down to press
INSTALLER OPTIONS
.
Enter the date code (password) when prompted. The date code is printed on the
back of the thermostat; or press
MENU > EQUIPMENT STATUS
to find the date code.
After you enter the password, press
CREATE SETUP
to setup the thermostat.
A brief summary of installer options follows. You can download a complete list of all
options at http://customer.honeywell.com.
1000 Language
B
1010 Residential/Commercial
B
1030
Device Name
B
1030
Device Name on Home Screen
C
1040 Programmable/Non-programmable
B
1050 Fahrenheit/Celsius
B
1052
Indoor Equipment Type
B
1053
Air Handler Heater Kit Installed
B
1054
Outdoor Equipment Type
B
1056
Air Conditioner Communication
B
1058
Furnace Type
B
1059
Air Conditioner/Heat Pump Type
B
1060
Outdoor Air Sensor
B
2190
System Zoning - Backup Heat Control
B
3000
Manual/Auto Changeover
B
3000
Auto Changeover Deadband
B
3010
Temperature Control Options
B
3020
Finish With High Cool Stage
B
3021
Finish With High Heat Stage
B
3030
Staging Control - Cool Differentials
B
3050-3060 Staging Control - Heat Differentials
B
3090
Staging Control - Backup Heat Differentials
B
3110
Backup Heat Upstage Timer
B
3120
Outdoor Compressor Lockout
B
3120
Outdoor Backup Heat Lockout
B
3140
Cool/Compressor Cycles Per Hour
B
3150
Heat Cycles Per Hour
B
3160
Backup Heat Cycles Per Hour
B
3170-3190 Cooling Derivative, Integral, Throttling range
C
3200-3220 Heating Derivative, Integral, Throttling range
C
3240
Minimum Compressor Off Time
B
3260
Extended Fan Run Time in Cool
B
3260
Extended Fan Run Time in Heat
B
4000
Number of Schedule Periods
B
4010
Pre-occupancy Purge Duration
C
4020
Override: Standard or Initiate Occupancy
C
4030
Override Duration
C
4050
Minimum Recovery Settings - Heat
C
4060
Maximum Recovery Settings - Heat
C
4070
Minimum Recovery Settings - Cool
C
4080
Maximum Recovery Settings - Cool
C
4090
Adaptive Intelligent Recovery
R
4100
Minimum Cool Setpoint
B
4100
Maximum Heat Setpoint
B
4110
Keypad Lockout
B
4120
Entry/Exit Remote -
Home/Occupied Cool Setpoint
B
4120
Entry/Exit Remote -
Home/Occupied Heat Setpoint
B
4130
Entry/Exit Remote -
Away/Unoccupied Cool Setpoint
B
ISU
Function
ISU
Function
R
: Residential
C
: Commercial
B
: Both