![Honeywell ComfortNET CTK04 System Installation Manual Download Page 13](http://html.mh-extra.com/html/honeywell/comfortnet-ctk04/comfortnet-ctk04_system-installation-manual_154018013.webp)
CTK04 ComfortNet™ Communicating Thermostat
13
I/O-CHTSTAT03 69-2688—11
ComfortNet User Menu
Press
MENU
>
COMFORTNET USER MENU
Press
MENU
and scroll down to press
COMFORTNET USER MENU
. Enter the date code
(password) when prompted. The date code is printed on the back of the thermostat;
or press
MENU > EQUIPMENT STATUS
to find the date code.
Each piece of equipment is divided into categories which may include: (Not all
menu options listed here may be available. Additional menu options may be dis-
played on the thermostat.)
•
Diagnostics
:
Provides a fault history of the equipment and allows the
installer to clear the fault history.
•
Identification:
Provides the model and serial number of the equipment and
software revision information.
•
Sensors:
Provides the sensor data of the equipment. In some instances, it
4130
Entry/Exit Remote -
Away/Unoccupied Heat Setpoint
B
4140
Entry/Exit Remote -
Vacation/Holiday Cool Setpoint
B
4140
Entry/Exit Remote -
Vacation/Holiday Heat Setpoint
B
5040
Indoor Sensors Used for Temperature Control
B
7000
Filter Type
B
7020
Number of Air Filters
B
7110
Air Filter Replacement Reminder
B
7110
Air Filter 2 Replacement Reminder
B
7120
EAC Cell Cleaning Reminder
B
7120
EAC Pre-Filter Cleaning Reminder
B
7120
EAC Post-Filter Replacement Reminder
B
8000
Humidifier Type
B
8010
Indoor Sensor Used for Humidification Control
B
8050
Humidification - Window Protection
B
8060
System Modes Allowing Humidification
B
8070
Humidification Control
B
8100
Clean Tank / Water Filter Replacement Reminder
B
8100
Humidifier Pad Replacement Reminder
B
9000
Dehumidification Equipment
B
9010
Indoor Sensor Used for Dehumidification Control
B
9020
Humidity Sensor Displayed on the Home Screen
B
9070
Dehumidification - Overcooling Limit
R
9080
Dehumidification Control
C
9090
Dehumidification Minimum On Time
C
9100
High Humidity Comfort Reset Setting
C
9180
Dehumidification Away Mode
B
9190
Dehumidification Away Mode - Fan Control
B
9200
Dehumidification Away Mode -
Low Limit Temperature
B
9200
Dehumidification Away Mode -
Temperature Setting
B
9200
Dehumidification Away Mode -
Dehumidification Setting
B
9210
Dehumidifier Filter Replacement Reminder
B
10000
Ventilation Type
B
10050
Ventilation Control Method
B
10090
Number of Bedrooms
R
10090
Size of House
R
10100
Enter Equipment Ventilation Rate
R
10120
Ventilation Percent On Time
B
10170
Ventilator Filter Cleaning Reminder
B
11000
Number of UV Devices
B
11050
UV Bulb Replacement Reminder
B
11050
UV Bulb 2 Replacement Reminder
B
12000
Installer Custom Reminders
B
14000
Clock Format
B
14010
Daylight Saving Time
B
14020
Indoor Temperature Display Offset
B
14020
Indoor Humidity Display Offset
B
15000-15020 Dealer name, phone, email, website, message
B
Installer options (ISU)
6
ISU
Function
ISU
Function
may allow the installer to setup or turn off a sensor.
•
Setup:
Allows the installer to change the settings of the equipment.
•
Status:
Provides the current status of the equipment.
See equipment installer manual for specific submenu options available within
each category.