background image

Updating CIU 888 Site configuration

Part No.: 4417593_Rev09

Ensite Pro to CIU 888 Migration Manual

CIU 888

4 - 1

$*6

CHAPTER 4 UPDATING CIU 888 SITE CONFIGURATION 

If there are changes in the CIU 888 system setup, these changes must

be  implemented  in  the  site  configuration.  Subsequently,  the  updated

site configuration must be uploaded to the CIU 888 for the changes to

become effective.
Changes in the CIU 888 system setup can be the result of, for example:

Connection of additional tank gauging instruments to the CIU 888

Connection of additional host systems to the CIU 888

Installation of a new CIU 888 license resulting in the expansion of the

features and functionalities of the CIU 888 (e.g. redundancy, support

of a larger number of tanks)

The procedure  for updating the CIU 888 site  configuration consists of

the following steps:
1. Implementing  the  required  changes  in  the  site  configuration  and

regenerating the INI files, see section 4.2

2. Regenerating the INI files required for Entis Pro, see section 4.3
3. Uploading  the  updated  site  configuration  to  the  CIU 888,  see

section 4.4

4. If  required,  configuring  the  additional  configuration  settings,  see

section 4.5

5. Updating the INI files required for Entis Pro, see section 4.6
6. Restarting  the  Entis  Pro  system  connected  to  the  CIU  888,  and

reloading the INI files in Entis Pro, see section 4.7

7. Sealing the CIU 888, see section 4.8
8. Verifying the working of the system setup, see section 4.9

4.1 Requirements for updating the CIU 888 site configuration

The following requirements must have been met in order to update the

CIU 888 site configuration: 

The  CIU 888  must  be  switched  on.  See  section 5.1.1  for  more

information.

Both the W&M lock key switch and the Configuration lock key switch

of  the  CIU 888  must  be  in  ‘unlocked’  position.  See  section 5.2  for

more information.

A  PC/laptop  running  the  CIU 888  Configuration  System  must  be

connected to the Service port of the CIU 888 using a Cat. 5 Ethernet

cable (patch or crossover). The Service port is located at the front of

Summary of Contents for CIU 888

Page 1: ... 6 Ensite Pro to CIU 888 Migration Manual Release R140 ...

Page 2: ......

Page 3: ...for example a gauge is added or an additional host system is connected these changes need to be implemented and the CIU 888 needs to be updated with the new site configuration Purpose of this manual The purpose of this manual is to provide information about the commissioning and configuration of the CIU 888 Target audience of this manual This manual is primarily intended for service technicians wh...

Page 4: ...Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 ii CIU 888 6 This page is intentionally left blank ...

Page 5: ...2 2 1 Logging on to the CIU 888 and changing the initial password 2 2 2 2 2 Verifying the CIU 888 license 2 4 2 3 Setting up the site configuration and generating INI files 2 6 2 3 1 Supported topologies of deployment 2 6 2 3 1 1 Single CIU Prime 2 7 2 3 1 2 Single pair of CIU Plus and CIU Prime 2 8 2 3 2 Mapping of host ports 2 8 2 3 3 Configuration procedure in Ensite Pro 2 10 2 3 4 Generating I...

Page 6: ...4 Updating CIU 888 Site configuration 4 1 4 1 Requirements for updating the CIU 888 site configuration 4 1 4 2 Implementing the required changes in the site configuration 4 2 4 3 Regenerating the INI files 4 3 4 4 Uploading the updated site configuration to the CIU 888 4 4 4 5 Configuring the additional configuration settings 4 7 4 6 Updating the INI files 4 7 4 7 Restarting Entis Pro and reloadin...

Page 7: ... 5 A 2 3 1 Date A 5 A 2 3 2 Time A 6 A 3 List of entities not needing restart after a change A 6 APPENDIX B Scanning B 1 B 1 Scanning Philosophy B 1 B 2 Configured Foreground scan items B 1 B 3 Configured Background scan items B 1 B 4 Command scan items B 2 B 5 Service Messages B 2 B 6 Priority Agent B 2 APPENDIX C Redundancy C 1 C 1 Sync Link and database synchronization C 1 C 2 Supported redunda...

Page 8: ...Table of Contents Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 vi CIU 888 6 This page is intentionally left blank ...

Page 9: ...figuration of the CIU 888 The CIU 888 Configuration System is typically installed on a PC laptop running Windows 7 which in turn is connected to the CIU 888 via the Service port located at the front of the CIU 888 see FIGURE 1 1 FIGURE 1 1 CIU 888 Service port FIGURE 1 2 shows a graphic overview of the CIU 888 Configuration System and the CIU 888 FIGURE 1 2 Graphic overview of the CIU 888 Configur...

Page 10: ... 7 Microsoft Internet Explorer 10 x or 11 x or Google Chrome version 43 See also section 1 4 1 1 2 Ensite Pro The Ensite Pro configuration tool version 3 0 or higher is used to create and configure the site and data inputs gauging instruments tanks including tank strapping tables and CIUs and to configure the links between the individual site elements FIGURE 1 3 shows the Ensite Pro tool bar and a...

Page 11: ...site Pro splash screen is displayed see FIGURE 1 4 followed by the Ensite Pro login window see FIGURE 1 5 FIGURE 1 4 Ensite Pro splash screen FIGURE 1 5 Ensite Pro login window 2 Enter the username and password to log in to Ensite Pro Next click OK After entering a valid username and password the Ensite Pro tool bar is displayed see FIGURE 1 6 FIGURE 1 6 Ensite Pro tool bar Select Site button acti...

Page 12: ...eated by Ensite Pro FIGURE 1 7 Ensite Pro to CIU 888 Migration tool Furthermore the Ensite Pro to CIU 888 Migration tool is used for updating the INI files needed for the Entis Pro tank inventory management system 1 3 1 Launching the Ensite Pro to CIU 888 Migration tool Before the Ensite Pro to CIU 888 Migration tool can be launched the Migration tool files need to be copied to the PC laptop Subse...

Page 13: ... and the Configuration lock key switch Performing system hardware diagnostics Users can view for example CIU 888 RAM usage carrier board temperatures last power down time including reason et cetera View audit and event records logged by the CIU 888 Installing firmware upgrades Updating the CIU 888 license The CIU 888 Web interface can be accessed using a standard browser NOTE In this release only ...

Page 14: ...r Next press the Enter key The following warning is displayed see FIGURE 1 8 FIGURE 1 8 Website s security certificate problem b Click the Continue to this website not recommended option You will go back to Microsoft Internet Explorer c At the right of the address bar click Certificate Error The Untrusted Certificate pop up window is displayed see FIGURE 1 9 FIGURE 1 9 Untrusted Certificate pop up...

Page 15: ... overview Part No 4417593_Rev09 Ensite Pro to CIU 888 Migration Manual CIU 888 1 7 6 d Next click View certificates The Certificate window is displayed Verify the certificate details see FIGURE 1 10 FIGURE 1 10 Certificate window ...

Page 16: ... Install Certificate button The Certificate Import Wizard Welcome window is displayed see FIGURE 1 11 FIGURE 1 11 Certificate Import Wizard Welcome window f Click the Next button The Certificate Import Wizard Certificate Store window is displayed see FIGURE 1 12 FIGURE 1 12 Certificate Import Wizard Certificate Store window ...

Page 17: ...on The Select Certificate Store window is displayed see FIGURE 1 13 FIGURE 1 13 Select Certificate Store window h Select Trusted Root Certification Authorities Next click the OK button to save the settings and to close the window i Click the Next button The Certificate Import Wizard Completing window is displayed see FIGURE 1 14 FIGURE 1 14 Certificate Import Wizard Completing window j Click the F...

Page 18: ...art No 4417593_Rev09 1 10 CIU 888 6 REMARK If a Security Warning message is displayed see FIGURE 1 15 click the Yes button and then the OK button FIGURE 1 15 Security Warning message k From the Tools menu select the Internet Options option The Internet Options window is displayed ...

Page 19: ...iew Part No 4417593_Rev09 Ensite Pro to CIU 888 Migration Manual CIU 888 1 11 6 l Go to the Content tab FIGURE 1 16 Internet Options window Content tab m Click the Certificates button The Certificates window is displayed see FIGURE 1 17 ...

Page 20: ...s listed p Click the Close button to close the window You will go back to the Internet Options window q Click the OK button to close the window r Close all instances of Microsoft Internet Explorer s Restart Microsoft Internet Explorer 1 4 2 Changing the settings of Google Chrome To access the CIU 888 using Google Chrome version 40 or later the following changes in the browser settings need to be i...

Page 21: ... 6 a Go to Settings Show advanced settings HTTPS SSL and click the Manage certificates button FIGURE 1 18 Navigate to the Manage certificates button on Google Chrome b In the ensuing Certificates window click the Import button to launch the Certificate Import Wizard FIGURE 1 19 Certificates window Import button ...

Page 22: ...0 Welcome screen d Click the Browse button and select the certificate file with a p7b extension You must select PKCS 7 certificates option to view the certificate file with the p7b extension FIGURE 1 21 Browse to the certificate file e Click Next f In the Certificate Store screen select the Place all certificates in the following store option and click Browse ...

Page 23: ...anual CIU 888 1 15 6 g Click the Trusted Root Certification Authorities folder and click OK FIGURE 1 22 Select folder to save certificate file h Click Next Details of the certificate file you are importing are displayed Verify the details and click Finish FIGURE 1 23 Verify certificate details ...

Page 24: ...CIU 888 Migration Manual Part No 4417593_Rev09 1 16 CIU 888 6 i If a warning message appears click Yes and continue FIGURE 1 24 Warning message j After the certificate is installed a confirmation message appears Click OK FIGURE 1 25 Confirmation message ...

Page 25: ...certificate 1 4 3 Launching the CIU 888 Web interface Perform the following steps to launch the CIU 888 Web interface 1 Launch a browser NOTE In this release only Internet Explorer 10 and 11 and Google Chrome version 40 or later are supported 2 Enter the IP address of the CIU 888 in the address bar of the browser The IP address is 192 168 1 1 Next press the Enter key The CIU 888 Login window is di...

Page 26: ...al Part No 4417593_Rev09 1 18 CIU 888 6 3 Enter the username and password to log in to the CIU 888 The username is ciuadmin Next click LOG IN After entering a valid username and password the CIU 888 Web interface is displayed see FIGURE 1 28 FIGURE 1 28 CIU 888 Web interface ...

Page 27: ...I files in Entis Pro see section 2 8 8 Sealing the CIU 888 see section 2 9 9 Verifying the working of the system setup see section 2 10 2 1 Requirements for commissioning For the commissioning of a standalone CIU 888 system setup the following requirements must have been met The electrical and mechanical installation of the CIU 888 must be completed Refer to the Installation Manual CIU 888 Part No...

Page 28: ...al setup a user has to log on to the CIU 888 and change the initial password first Procedure 1 On the PC laptop connected to the CIU 888 launch a browser NOTE In this release only Internet Explorer 10 and 11 and Google Chrome version 40 or later are supported 2 Enter the IP address of the CIU 888 in the address bar of the browser The IP address is 192 168 1 1 Next press the Enter key The Login win...

Page 29: ... the CIU 888 4 Change the password of the ciuadmin account a Enter the current password in the Old Password text box b Enter the new password in the New Password text box and in the Confirm Password text box The password must meet the following criteria It must not be the same as the previous password It must not contain any dictionary words e g password It must be at least eight characters long I...

Page 30: ...by default see FIGURE 2 4 FIGURE 2 4 CIU 888 Web interface Diagnostics window 2 2 2 Verifying the CIU 888 license When the initial password has been changed the next step is to verify if a license is installed on the CIU 888 and if the license installed supports the functionality ordered by the customer NOTE Refer to the Firmware Upgrade Manual Part No 4417596 for more information about the CIU 88...

Page 31: ...CIU 888 Web interface click CONFIGURE in the section menu bar The Configure window is displayed see FIGURE 2 5 FIGURE 2 5 CIU 888 Web interface Configure window 2 If a license is installed on the CIU 888 LICENSE_OK is displayed in the License status field If no license is installed the field is empty In this case contact Honeywell Enraf ...

Page 32: ...0 site configuration and implementing the required changes so that the site configuration meets one of the supported topologies of deployment The supported topologies are described in section 2 3 1 2 3 1 Supported topologies of deployment In case of setting up a site configuration for a CIU 888 in a standalone system setup the following topologies of deployment are supported Single CIU Prime conne...

Page 33: ...t will match the changed site configuration 2 3 1 1 Single CIU Prime In this topology a single CIU Prime is connected to a host system i e DCS PLC or SCADA system via one of its two host ports see FIGURE 2 7 A configured host port has its own unique RTU address and enables Modbus RTU on serial communication FIGURE 2 7 Schematic representation of a site with a single CIU Prime A maximum of four fie...

Page 34: ... a site with a single pair of CIU Plus and CIU Prime On the CIU Prime a maximum of four field ports are available to connect to tank gauging instruments The field ports can be configured for GPU on Bi Phase Mark communication or GPU on serial communication The CIU Prime and the CIU Plus are connected to one another via one of the host ports of the CIU Prime and one of the field ports of the CIU Pl...

Page 35: ...ime host port 1 is ignored CIU Prime host port 2 is mapped to CIU 888 fixed host port 2 CIU Plus host port 1 is mapped to CIU 888 fixed host port 1 CIU Plus host port 3 is mapped to CIU 888 optional slot 5 CIU Plus host port 4 is mapped to CIU 888 optional slot 6 CIU emulation compatible with the CIU 858 can be configured for any of the CIU 888 host ports For example If CIU 888 fixed host port 2 m...

Page 36: ...nfiguration Tool version 3 0 Part No 4416593 1 Preparation Before starting with creating and configuring the site a number of details must be known e g site layout information about field cabling tag names of site elements i e gauges tanks and CIUs tank information tank strapping tables or tank capacity tables roof details etc information on types of stored product host communication setup if appl...

Page 37: ...ports 1 through 4 required to make the CIU Plus compatible with the connected hardware and software i e Entis Pro PLC or DCS Hot standby required if redundant CIU Primes and or CIU CIU Pluses are installed Field port 1 Field port 2 7 Linking of the data inputs tanks and CIUs The site configuration created with Ensite Pro is saved as a Microsoft Access Database file mdb file in the folder Drive Use...

Page 38: ...loading the site configuration to the CIU 888 When the site configuration has been set up and the INI files have been generated the next step is to upload the site configuration to the CIU 888 using the Ensite Pro to CIU 888 Migration tool 1 Launch the Ensite Pro to CIU 888 Migration tool The Ensite Pro to CIU 888 Migration tool is launched FIGURE 2 11 Ensite Pro to CIU 888 Migration tool 2 Enter ...

Page 39: ... files will be stored is automatically selected If necessary you can change the folder by clicking Browse to browse to the appropriate folder Remember settings Select the check box if the current settings must be saved 3 Click Upload to CIU 888 The following dialogue box is displayed see FIGURE 2 12 FIGURE 2 12 Successfully Migrated dialogue box Create New Configuration Deletes the existing site c...

Page 40: ... 2 13 FIGURE 2 13 Successfully Migrated dialogue box 5 Click OK to close the dialogue box 6 Leave the Ensite Pro to CIU 888 Migration tool open since it will be needed for updating the INI files 2 5 Configuring the additional configuration settings of the CIU 888 When the Ensite Pro site configuration has been uploaded to the CIU 888 the next step is to the configure the additional configuration s...

Page 41: ...t No 4417593_Rev09 Ensite Pro to CIU 888 Migration Manual CIU 888 2 15 6 2 Click CONFIGURE in the section menu bar The Configuration window is displayed see FIGURE 2 14 FIGURE 2 14 CIU 888 Web interface Configuration window FlexConn address setting ...

Page 42: ...l is beyond the configured Tank high monitoring limit Tanks with field device com munication errors See Chapter B section B 6 for Priority Details Enabled Disabled Enabled HostPort TRDT Sup press Moving Status Indicates whether Moving status is suppressed or not in the CIU888 s Modbus Tank record Enabled Moving status suppressed Disabled Moving status suppressed Enabled Disabled Disabled Tank High...

Page 43: ...ded to the Entis Pro inventory system 1 Select the Gauge type as 854 in the Ensite Pro configuration and configure other gauge settings as required 2 Upload the configuration to CIU 888 Refer to section 2 4 Uploading the site configuration to the CIU 888 for the procedure 3 Launch the CIU 888 Web interface see section 1 4 2 4 From the section menu bar click CONFIGURE The Configure window is displa...

Page 44: ...e Pro to CIU 888 Migration Manual Part No 4417593_Rev09 2 18 CIU 888 6 5 Click the required gauge in the siteelement tree Gauge configuration appears in the right pane 6 Select the Gauge type as 954 and set the Flexconn Address to the required value ...

Page 45: ... Manual CIU 888 2 19 6 7 Select the Gauge type as 854 and then click Update 2 6 End commissioning of the CIU 888 When the additional configuration settings of the CIU 888 have been configured the next step is to end commissioning of the CIU 888 1 Launch the CIU 888 Web interface see section 1 4 2 ...

Page 46: ...figure window is displayed see FIGURE 2 16 FIGURE 2 16 CIU 888 Web interface Configuration window 3 Click End Commissioning The following dialogue box is displayed see FIGURE 2 17 FIGURE 2 17 Commissioning ended successfully dialogue box 4 Click OK to close the dialogue box The CIU 888 restarts When the CIU 888 is restarted it will run using the new site configuration ...

Page 47: ...Ensite Pro to CIU 888 Migration tool under Ini Files check the INI file path The INI file path is automatically selected when the Ensite Pro site database has been selected See also section 2 4 FIGURE 2 18 Ensite Pro to CIU 888 Migration tool 2 Click Update The INI files are updated When the INI files have been updated successfully the following dialogue box is displayed see FIGURE 2 19 FIGURE 2 1...

Page 48: ...tative of the W M authorities or by a W M accredited user Refer to the CIU 888 Sealing Guide Part No 4417595 for more information NOTE If the CIU 888 does not feature the option to be sealed the W M configuration settings can either be locked or left unlocked 2 10 Verifying the working of the system setup The final step in the commissioning procedure is verifying if the CIU 888 system setup is wor...

Page 49: ...ol bar is displayed see FIGURE 2 21 FIGURE 2 21 Ensite Pro tool bar Select Site button is active 4 Click Select Site button The Select Site window is displayed see FIGURE 2 22 FIGURE 2 22 Ensite Pro Select Site window 5 Select the appropriate site Next click the Select button The Select Site window is closed and all buttons in the Ensite Pro tool bar are active see FIGURE 2 23 FIGURE 2 23 Ensite P...

Page 50: ...the lights are blinking data is being sent and received c Select the CIU Plus from the drop down list d Select the tank from the drop down list The data of the selected tank will be displayed e Check the tank data for the following Do the measured items match the gauge readings Is the TOV correct based on level and STRAP tables of this tank Are WVol GOV and GSV reasonable f Repeat steps d through ...

Page 51: ...Modbus serial is one such example NOTE Refer to the Protocol Manual Modbus Host Part No 4417588 for more information about setting up of Modbus host for redundancy NOTE The active CIU 888 can either be the primary CIU 888 or the secondary CIU 888 The redundancy status of the CIU 888 active or passive is presented through the following host systems Entis Pro via Modbus serial commands both CIU 888s...

Page 52: ...ry CIU 888 and the secondary CIU 888 must be switched on See section 5 1 1 for more information The W M lock key switch and the Configuration lock key switch of both the primary CIU 888 and the secondary CIU 888 must be in unlocked position See section 5 2 for more information The primary CIU 888 and the secondary CIU 888 must be linked through their Sync Link ports using a Cat 5 Ethernet cable pa...

Page 53: ... 3 Setting up the site configuration and generating INI files When the initial setup of the primary CIU 888 is completed the next step is to set up the site configuration using Ensite Pro The site configuration can be set up either by Creating a new site configuration or Copying an existing CIU 880 site configuration and implementing the required changes so that the site configuration meets one of...

Page 54: ...ured in the same site database the site configuration needs to be manually edited to match one of these configurations Another option could be to create a copy of the existing site configuration and then delete the site elements not required to be imported It is of course necessary that the mechanical and electrical installation is also adjusted so it will match the changed site configuration 3 3 ...

Page 55: ...Phase Mark communication or GPU on serial communication In each pair the CIU Prime and the CIU Plus are connected to one another via one of the host ports of the CIU Prime and one of the field ports of the CIU Plus NOTE A cross connection between the two pairs in which the primary CIU Plus is connected to the secondary CIU Prime and the secondary CIU Plus is connected to the primary CIU Prime is n...

Page 56: ... CIU Prime Redundant host systems On the CIU Prime a maximum of four field ports are available to connect to the tank gauging instruments The field ports can be configured for GPU on Bi Phase Mark communication or GPU on serial communication In each pair the CIU Prime and the CIU Plus are connected to one another via one of the host ports of the CIU Prime and one of the field ports of the CIU Plus...

Page 57: ...stem CIU Prime host port 1 is ignored CIU Prime host port 2 is mapped to CIU 888 optional slot 6 CIU Plus host port 1 is mapped to CIU 888 fixed host port 1 CIU Plus host port 2 is mapped to CIU 888 fixed host port 2 CIU Plus host port 3 is mapped to CIU 888 optional slot 5 CIU emulation compatible with the CIU 858 can be configured for any of the CIU 888 host ports For example If CIU 888 fixed ho...

Page 58: ... configuration for a redundant system setup is similar to the procedure for setting up the site configuration for a standalone system setup this section focuses on the changes that need to be made when setting up the site configuration of a redundant system setup NOTE Refer to the Instruction manual Ensite Pro Configuration Tool version 3 0 Part No 4416593 for detailed information about setting up...

Page 59: ...IU 888 Migration Manual CIU 888 3 9 6 The Hot Standby enabled option must be selected The primary CIU Prime has the secondary CIU Prime as its counterpart and fulfills the Primary role see FIGURE 3 7 FIGURE 3 7 Ensite Pro Hot standby configuration settings of the primary CIU Prime ...

Page 60: ...sed on the settings of the primary CIU Prime see FIGURE 3 8 FIGURE 3 8 Ensite Pro Hot standby configuration settings of the secondary CIU Prime The site configuration for a redundant system setup contains two CIU Pluses a primary CIU Plus and a secondary CIU Plus The configuration settings of both CIU Pluses must be the same with the exception of the RTU addresses of the configured host ports Thes...

Page 61: ...ary CIU Plus as its counterpart and fulfills the Primary role see FIGURE 3 9 FIGURE 3 9 Ensite Pro Hot standby configuration settings of the primary CIU Plus The type of connection is always CIU Primes connected to one Plus only With this type of connection each CIU Prime in the redundant system setup is connected to one CIU Plus i e the primary CIU Prime is connected to the primary CIU Plus and t...

Page 62: ...setup CIU Prime connected to single CIU Plus NOTE If in an existing redundant system setup the option CIU Primes connected to both primary and secondary Plus is selected as type of connection this setting has to be changed to CIU Primes connected to one Plus only Furthermore the cabling between the primary CIU Prime CIU Plus and the secondary CIU Prime CIU Plus needs to be changed so it will match...

Page 63: ...y CIU Plus are automatically configured based on the Hot standby configuration settings of the primary CIU Plus FIGURE 3 11 Ensite Pro Hot Standby configuration settings of the secondary CIU Plus HostPort 1 of the primary CIU Prime must be linked to FieldPort 1 of the primary CIU Plus see FIGURE 3 12 FIGURE 3 12 Ensite Pro CIU Prime linked to CIU Plus through Field port 1 ...

Page 64: ...NI files needed for Entis Pro Refer to the Instruction manual Ensite Pro Configuration Tool version 3 0 Part No 4416593 for detailed information about generating INI files using Ensite Pro 3 4 Uploading the site configuration to the primary CIU 888 When the site configuration has been set up and the INI files have been generated the next step is to upload the site configuration to the primary CIU ...

Page 65: ...IU 888 When the primary CIU 888 has been commissioned the next step is to configure its counterpart as preferred secondary CIU 888 Procedure 1 On the display of the secondary CIU 888 highlight the Configuration icon in the Status Dashboard using the navigation keys Next press the OK button The Configuration menu screen is displayed see FIGURE 3 14 FIGURE 3 14 CIU 888 display Configuration menu scr...

Page 66: ...ion using the display keys Next press the OK key The secondary CIU 888 will be reset to the factory settings and will reboot twice Because the Entis Pro system s connected to the CIU 888s is shutdown redundancy switchover will be disabled during reboot When commissioning of both the primary CIU 888 and secondary CIU 888 has been completed the role of each CIU 888 in the redundant system setup is i...

Page 67: ... updated INI files in Entis Pro Refer to the Configuration manual Entis Pro version 2 70x for Windows 7 Part No 4416381 for more information 3 10 Sealing the CIU 888s If the CIU 888s feature the option to be sealed the next step is to have them sealed by a representative of the W M authorities or by a W M accredited user Refer to the CIU 888 Sealing Guide Part No 4417595 for more information NOTE ...

Page 68: ...Commissioning of a Redundant System Setup Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 3 18 CIU 888 6 This page is intentionally left blank ...

Page 69: ...the INI files see section 4 2 2 Regenerating the INI files required for Entis Pro see section 4 3 3 Uploading the updated site configuration to the CIU 888 see section 4 4 4 If required configuring the additional configuration settings see section 4 5 5 Updating the INI files required for Entis Pro see section 4 6 6 Restarting the Entis Pro system connected to the CIU 888 and reloading the INI fil...

Page 70: ...dating of the CIU 888 site configuration the Entis Pro system connected to the CIU 888 must be shut down 4 2 Implementing the required changes in the site configuration The first step in updating the CIU 888 site configuration is implementing the required changes in the site configuration Procedure 1 Launch Ensite Pro see section 1 2 1 The Ensite Pro tool bar is displayed see FIGURE 4 2 FIGURE 4 2...

Page 71: ...l bar All buttons are active 4 Implement the required changes to the site configuration Refer to the Instruction manual Ensite Pro Configuration Tool version 3 0 Part No 4416593 for detailed information about the complete configuration procedure in Ensite Pro 4 3 Regenerating the INI files When the required changes in the site configuration have been implemented the next step is to regenerate the ...

Page 72: ... 888 Migration tool is displayed see FIGURE 4 5 FIGURE 4 5 Ensite Pro to CIU 888 Migration tool 2 Enter the following information Ensite Pro Site Database File Select the Ensite Pro site database mdb file Click Browse to browse to the appropriate folder and then select the mdb file After selecting the site database file the file name including the full path is displayed Enter Service Port Address ...

Page 73: ... Upload the configuration to CIU 888 it may trigger unexpected results and user may not be able to perform update configuration again The only way to recover from this situation is to do a factory reset of the CIU 888 and recommission the CIU 888 3 Click Upload to CIU 888 If the implemented changes do not require a restart of the CIU 888 the following dialogue box is displayed FIGURE 4 6 Migration...

Page 74: ...ges to the site configuration are uploaded to the CIU 888 When the implemented changes have been successfully uploaded and the changes did not required a restart of the CIU 888 the following dialogue box is displayed see FIGURE 4 8 FIGURE 4 8 Migration tool Successfully Migrated dialogue box When the implemented changes have been successfully uploaded and the changes required a restart of the CIU ...

Page 75: ... step is to update the INI files needed for Entis Pro See section 4 for more information 4 7 Restarting Entis Pro and reloading updated INI files in Entis Pro When the INI files have been updated the next step is to restart the Entis Pro system connected to the CIU 888 and then reload the updated INI files in Entis Pro Refer to the Configuration manual Entis Pro version 2 70x for Windows 7 Part No...

Page 76: ...Updating CIU 888 Site configuration Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 4 8 CIU 888 6 ...

Page 77: ...start the CIU 888 using the on off switch at the back of the device see FIGURE 5 1 FIGURE 5 1 CIU 888 on off switch During startup the CIU 888 Loading splash screen is shown on the CIU 888 display see FIGURE 5 2 FIGURE 5 2 CIU 888 display CIU 888 Loading splash screen NOTE If the CIU 888 is built into a storage cabinet the on off switch should be in the ON position as it is no longer accessible In...

Page 78: ...5 3 FIGURE 5 3 CIU 888 Web interface Restart CIU option in CIU 888 menu During restart the CIU 888 Restarting splash screen is shown on the CIU 888 display see FIGURE 5 4 FIGURE 5 4 CIU 888 display CIU 888 Restarting splash screen 5 1 3 Shutting down the CIU 888 Shutting down the CIU 888 is necessary if for instance maintenance must be performed on the CIU 888 or if the CIU 888 must be replaced Yo...

Page 79: ... FIGURE 5 5 CIU 888 Web interface Shutdown CIU option in CIU 888 menu NOTE To switch the CIU 888 back on use the on off switch at the back of the device see section 5 1 1 Because the on off switch is still in the ON position the on off switch must be switched to the OFF position first Subsequently the CIU 888 can be started by switching the on off switch to the ON position ...

Page 80: ...e W M relevant configuration settings of the CIU 888 The key switch is located at the front of the CIU 888 and is fitted with a cover see FIGURE 5 6 FIGURE 5 6 CIU 888 W M lock key switch 5 2 1 1 Unlocking the W M relevant configuration settings Perform the following steps to unlock the W M relevant configuration settings of the CIU 888 1 If the cover of the W M lock key switch is sealed remove th...

Page 81: ...m the key switch and store it 5 2 1 2 Locking the W M relevant configuration settings Perform the following steps to lock the W M relevant configuration settings of the CIU 888 1 Take the key for locking unlocking the W M relevant configuration settings 2 Insert the key in the W M lock key switch Next turn the key clockwise On the CIU 888 display the status of the W M lock key switch changes from ...

Page 82: ...at the front of the CIU 888 see FIGURE 5 9 FIGURE 5 9 CIU 888 Configuration lock key switch 5 2 2 1 Unlocking the configuration settings Perform the following steps to unlock the configuration settings of the CIU 888 1 Take the key for locking unlocking the configuration settings 2 Insert the key in the Configuration lock key switch and then turn the key counterclockwise On the Status Dashboard th...

Page 83: ...ock the configuration settings of the CIU 888 1 Take the key for locking unlocking the configuration settings 2 Insert the key in the Configuration lock key switch and then turn the key clockwise On the Status Dashboard the status of the Configuration lock key switch changes from unlocked to locked see FIGURE 5 11 FIGURE 5 11 Status Dashboard configuration settings are locked 3 Remove the key from...

Page 84: ...tering Safe mode CAUTION Do not perform Enter Safe Mode unless it is specified as a step in any of the configuration procedures or firmware upgrade procedures You can enter safe mode of CIU 888 via the CIU 888 Web interface To enter safe mode select Enter Safe Mode from the CIU 888 menu see figure 5 12 FIGURE 5 12 CIU 888 Web interface Enter Safe Mode option in CIU 888 menu 5 3 2 Exiting Safe mode...

Page 85: ...ro to CIU 888 Migration Manual CIU 888 5 9 6 You can exit safe mode of CIU 888 via the CIU 888 Web interface To exit safe mode select Exit Safe Mode from the CIU 888 menu see figure 5 13 FIGURE 5 13 CIU 888 Web interface Exit Safe Mode option in CIU 888 menu ...

Page 86: ...General CIU 888 Functions Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 5 10 CIU 888 6 This page is intentionally left blank ...

Page 87: ...ite configuration is uploaded to the CIU 888 To set the date and time the CIU 888 must be connected to the PC laptop running Ensite Pro part of the CIU 888 Configuration System via Service port located at the front of the CIU 888 using a Cat 5 Ethernet cable see FIGURE 6 1 FIGURE 6 1 CIU 888 Service port and One of the serial host ports located at the back of the CIU 888 using a serial cable see F...

Page 88: ... displayed FIGURE 6 3 Ensite Pro Set Date Time window 2 From the drop down list select the CIU for which you want to set the date and time 3 Enable the New date and time check box if you want to set a new date and time 4 Enter the time The format is Hours 00 23 Minutes 00 59 Seconds 00 59 Use the arrow buttons to increase or decrease the hours minutes or seconds 5 Select the month and year in the ...

Page 89: ... Migration Manual CIU 888 6 3 6 REMARK If the Daylight Saving Time ON option is enabled checked the clock is adjusted forward one hour near the start of spring and adjusted backward one hour in the autumn 7 Click the OK button to save the settings and to close the window ...

Page 90: ...Advanced CIU 888 Settings Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 6 4 CIU 888 6 This page is intentionally left blank ...

Page 91: ...imal separator The CIU 888 displays its floating point numeric data with a decimal separator which is either a dot default or a comma Other characters are not allowed A number cannot start nor end with a decimal separator So 0 2 is correct but 2 is not correct NOTE The decimal separator parameter falls under the W M seal A 2 1 2 Thousand separator The CIU 888 displays its numeric data with a thous...

Page 92: ...te Pro to CIU 888 Migration Manual Part No 4417593_Rev09 A 2 CIU 888 6 1 On the PC laptop running Ensite Pro go to Start Control Panel The Control Panel is displayed see FIGURE A 1 FIGURE A 1 Control Panel ...

Page 93: ..._Rev09 Ensite Pro to CIU 888 Migration Manual CIU 888 A 3 6 2 Click Clock Language and Region The Clock Language and Region applet is displayed see FIGURE A 2 FIGURE A 2 Control Panel Clock Language and Region applet ...

Page 94: ...88 Migration Manual Part No 4417593_Rev09 A 4 CIU 888 6 3 Click Region and Language The Region and Language window is displayed By default the Formats tab is displayed see FIGURE A 3 FIGURE A 3 Region and Language window ...

Page 95: ...ping symbol select the symbol to be used as thousand separator 7 Click OK to save the settings and to close the window A 2 2 Time stamped data Measured and calculated data is accompanied with a time stamp with the same resolution as the time stamp configured in the CIU 880 See section A 2 3 for more information about time resolutions A 2 3 Date and time presentation A 2 3 1 Date Dates are always p...

Page 96: ... and 24 mm zero padded minute between 00 and 59 ss zero padded second between 00 and 60 ttt zero padded between 000 and 999 A 3 List of entities not needing restart after a change TABLE A 1 List of CIU 888 entities that do not require a restart after changing Entity Name Entity Number TempElementType 8 ShellCapacity 17 LowTOV 18 HighTOV 19 VolumeCorrections 24 ProductTRef 26 ProductDref 30 SedAndW...

Page 97: ... TankZoneCorrection 4006 FloMul 5042 FloIntervalTime 5043 GaugeDetail 6500 GSVCalcType 8122 ProductCode 8133 TRDTStartAddressOfTankIP 15006 TRDTLengthOfTankRecordIP 15008 TRDTScalingIP 15013 TRDTOffsetIP 15014 HostPortDeviceName 15016 HostPortProtocolType 15019 HostPortRTUaddress 15020 HostPortBaudRate 15022 HostPortStopBits 15024 HostPortParity 15025 HostPortTAD 15026 HostPortMSUMode 15049 HostPo...

Page 98: ...Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 A 8 CIU 888 6 ...

Page 99: ...orts channel sequencing CIU 888 s scanning algorithm picks up the most useful item among all the scan items configured for the field ports that are sequenced The following are the various scan items processed by CIU 888 B 2 Configured Foreground scan items The CIU 888 scans measurable data inputs e g product level that are configured in the foreground scan more often than data inputs configured in...

Page 100: ...3 On receiving a valid response from the field the priority of the field device is moved to the appropriate level and retry mechanism is restored B 6 Priority Agent CIU 888 also incorporates a Priority Agent which monitors the product movement and product level close to Tank High limit and relatively prioritizes the scan items by modifying the minimum and maximum scan periods of the scan items so ...

Page 101: ...duct level when it is close to Tank high limit and no product movement is detected Product level when it is close to Tank high limit and device communication errors occur irrespective of product movement being detected not Normal Foreground parameters e g Level of static tanks i e no product movement is detected Product level of tanks where it was moving when device communication errors occur Serv...

Page 102: ...Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 B 4 CIU 888 6 This page is intentionally left blank ...

Page 103: ...on between the pair of CIU 888s must be established called the Sync Link The Sync Link connection is also used to determine the actual role of each CIU 888 active or passive To establish the Sync Link connection the CIU 888s have to be connected by means of a Cat 5 Ethernet cable In a redundant CIU 888 system setup the following data stores are kept synchronized Real time data Active gauge command...

Page 104: ...cy on demand of host system In this configuration both CIU 888s in the redundant configuration are connected to the same host system i e Entis Pro see FIGURE C 2 The CIU 888s are connected to the host system via one of their fixed host ports Each host port has its own unique RTU address and is configured for communication through Modbus RTU on serial FIGURE C 2 RS 232 Host port redundancy with red...

Page 105: ...The CIU 888s are connected to the host system via one of their fixed Host ports Each host port has its own unique RTU address and is configured for communication through Modbus RTU on serial By connecting each CIU 888 to a separate instance of Entis Pro an extra safety is created in the event of failure of one of the two host systems FIGURE C 3 RS 232 host port redundancy with redundant pair of CI...

Page 106: ...n Manual Part No 4417593_Rev09 C 4 CIU 888 6 NOTE Refer to the chapter CIU Plus Links in the Configuration Manual Entis Pro 2 70x for Windows Part No 4416381 for more information about connecting the CIU 888 to the Entis Pro system ...

Page 107: ...Unit DCS Distributed Control System GOV Gross Observed Volume GPU Gauge Processing Unit GSV Gross Standard Volume HTTP Hypertext Transfer Protocol PC Personal Computer PLC Programmable Logic Controller RAM Random Access Memory RTU Remote Terminal Unit SCADA Supervisory Control And Data Acquisition TOV Total Observed Volume W M Weights and Measures XML Extensible Markup Language ...

Page 108: ...Ensite Pro to CIU 888 Migration Manual Part No 4417593_Rev09 D 2 CIU 888 6 This page is intentionally left blank ...

Page 109: ...Phone 1 800 423 9883 or 1 215 641 3610 E mail HFS TAC SUPPORT honeywell com Copyright 2019 Honeywell All rights reserved No part of this manual may be reproduced in any form by print photoprint microfilm or any other means without the written permission from Honeywell ...

Page 110: ...thfield Ct Roswell GA 30076 USA Phone 1 770 475 1900 Email enraf us honeywell com Europe Middle East and Africa Honeywell Enraf Delftechpark 39 2628 XJ Delft the Netherlands Phone 31 0 15 2701 100 Email enraf nl honeywell com Asia Pacific Honeywell Pte Ltd 17 Changi Business Park Central 1 Singapore 486073 Phone 65 6355 2828 Email enraf sg honeywell com 4417593_Rev09 June 2019 2019 Honeywell ...

Reviews: