APPLICATION

The T4600 Chronotherm® Electronic Programmable Line
Voltage Thermostat provides line voltage control of
resistance-rated heating equipment. The patented
CoolSwitch™ thyristor commutator design provides long
service life. Depending on local climate, night and day
setback of space temperature can save up to 23% of the
energy used to heat a controlled space. The precise
temperature control of the T4600 also provides 12% energy
savings during most comfort periods as compared to
electromechanical wall thermostats.

FEATURES

Digital temperature sensing and control for energy-
efficient and precise (1.0

°

F) temperature control.

Liquid crystal display shows temperature and load
status.

Attractive contemporary styling.

Temperature range selectable between 45

°

F to 80

°

F

(7

°

C to 27

°

C).

Simple, pushbutton programming.

Weekday-weekend (5-2) programming for permanent
home (normal) operation.

Optional unoccupied low limit setting for seasonal
residence (cottage) operation.

Temporary temperature override.

Program override for seasonal temperature setback.

Permanent override for seasonal shutdown.

Rugged molded thermoplastic housing with captive
mounting screws.

Suitable for electric heaters such as convectors,
radiant cable, and non-inductive-rated, fan-forced
heaters.

Directly replaces two-wire, 240 Vac resistive-rated (up
to 10.4A of maximum 8 ft baseboard heater length) line
voltage thermostats.

Patented, long-life electronic switch and power supply
with nonpolarized leadwire connections.

Convenient 10-year program retention protects against
loss of program settings during seasonal setback
periods.

Contents

Application ........................................................................... 1
Features .............................................................................. 1
Specifications ......................................................................

2

Ordering Information ...........................................................

2

Installation ........................................................................... 3
Programming .......................................................................

5

Checkout .............................................................................

7

68-0168-3

Summary of Contents for Chronotherm T4600

Page 1: ...d status Attractive contemporary styling Temperature range selectable between 45 F to 80 F 7 C to 27 C Simple pushbutton programming Weekday weekend 5 2 programming for permanent home normal operation Optional unoccupied low limit setting for seasonal residence cottage operation Temporary temperature override Program override for seasonal temperature setback Permanent override for seasonal shutdow...

Page 2: ...itions are changed TRADELINE Models TRADELINE models are selected and packaged to provide ease of stocking ease of handling and maximum replacement value TRADELINE Models Available T4600A Chronotherm Electronic Programmable Line Voltage Thermostat with spst switching makes heating circuit on temperature fall Features TRADELINE pack Temperature Ratings Operating Range 22 to 104 F 30 to 40 C Control...

Page 3: ... AS REQUIRED SPECIAL SERVICE CO ALR SOLDERLESS CONNECTORS MUST BE USED WHEN CONNECTING ALUMINUM CONDUCTORS OTHERWISE A FIRE HAZARD CAN RESULT THERMOSTAT BREAKS HEATING CIRCUIT ON TEMPERATURE RISE THERMOSTAT IS DESIGNED TO BE USED WITH APPLIANCES EQUIPPED WITH A LIMIT CONTROL T4600A ELECTRONIC LINE VOLTAGE THERMOSTAT ELECTRIC HEATER BLACK BLACK M4788 Fig 2 T4600A Typical wiring connections PROG AUT...

Page 4: ...ad per thermostat must not exceed 2500W 8 ft of baseboard heater 2 Disconnect power to the thermostat to prevent electrical shock or equipment damage All wiring must comply with local electrical codes and ordinances 3 Remove the T4600 cover at the top or bottom edge with a slotted screwdriver 4 Remove the old thermostat from the wall taking care not to damage the wiring insulation 5 Check the old ...

Page 5: ...ramming by holding down the PROG key for four seconds or until the display shows the room temperature IMPORTANT The T4600 uses the time and day that was last in its memory as the basis for control Unexpected thermostat operation can occur when the clock is not set properly ACTIVITY RESULT DISPLAY SET THE TIME AND DAY Hours Press and release the PROG key The hour display flashes in the 12 hour AM P...

Page 6: ...ease the PROG key to enter the time PROGRAM THE DAY SETBACK AND AFTERNOON RECOVERY TIMES Day Setback Press the up and down keys to select the desired day setback time The display flashes the DAY setback time Afternoon Recovery Press the up and down keys to select the desired afternoon recovery time The display flashes the afternoon recovery warm up time Press and release the PROG key to enter the ...

Page 7: ... 20 C Let the system operate for at least one hour and adjust the setting as necessary M4657 AUTO MAN TEMPOR NIGHT DAY Su Mo Tu We Th Fr Sa AM PM ACTIVITY RESULT DISPLAY Set Cottage Programs CAUTION Before using the COTTAGE program make sure there are no water pipes along outside walls sealed in cabinets or installed in a manner that can cause them to freeze when the room temperature falls to 45 F...

Page 8: ...rdon Baker Road North York Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www honeywell com yourhome 68 0168 3 J S Rev 2 99 The electrical power industry of the U...