Honeywell Chronotherm T4600 Product Data Download Page 5

T4600 Chronotherm

 

®

 ELECTRONIC PROGRAMMABLE LINE VOLTAGE THERMOSTAT

68-0168—3

5

M4789

Su

PM

M4655

Su 

AM

M4790

Su     Mo  

AM

M4651

Su 

PM

M4648

NIGHT    DAY

M4650

NIGHT    DAY

M4657

AUTO   MAN   TEMPOR   NIGHT   DAY

Su     Mo     Tu     We     Th     Fr     Sa

AM
PM

PROGRAMMING

When the thermostat is first powered or if the battery is
drained, the display briefly shows all segments:

Then it shows 00E for 15 seconds followed by a flashing
12:00 AM (midnight) to indicate that the thermostat needs to
be programmed. If the time and day program is not entered,
the thermostat controls to the default setpoint, 60

°

F (16

°

C). If

the ambient temperature is below freezing, the display does
not operate until the power supply warms up the thermostat
to the operating temperature. There will be a clicking from the
relay, indicating the thermostat is working even though the
display is not restored.

The T4600 is programmed similar to other digital devices:
1. Press the PROG key to scroll through the program menus.
2. Press the up (+) and down (-) arrow keys to change the

values in the menus.

3. Press the AUTO key to select optional functions.

If no keys are pressed for ten seconds, the T4600 goes to
programmed operation and the room temperature is
displayed. Automatic operation is activated during
programming by holding down the PROG key for four
seconds or until the display shows the room temperature.

IMPORTANT

The T4600 uses the time and day that was last in its
memory as the basis for control. Unexpected
thermostat operation can occur when the clock is not
set properly.

ACTIVITY

RESULT

DISPLAY

SET THE TIME AND DAY
Hours: 
 
Press and release the PROG key.  

The hour display flashes in the 12-hour
(AM/PM) format.

Press and release the AUTO key for 24-hour
display, if desired. Press the up (+) and down
(-) keys to select the correct hour.

Midnight is displayed as 0:00 in 24-hour
format.

Press and release the PROG key to enter
the hour.

Minutes:
Press the up (+) and down (-) keys to select
the correct minutes.  

The minute display flashes.

Press and release the PROG key to enter
the minutes.

Day:
Press the up (+) and down (-) keys to select
the correct day of the week.

The current day flashes along the top of the
display.

Press and release the PROG key to enter
the day.

PROGRAM THE TEMPERATURE
SETTINGS
Press and release the AUTO key for the
Celsius temperature display, if desired.

Comfort Setpoint:
Press the up (+) and down (-) keys to select
the temperature for desired comfort setpoint.

The display flashes the comfort setpoint.

Press and release the PROG key to set the
comfort setpoint.

Economy Setpoint:
Press the up (+) and down (-) keys to select
the desired economy (setback) setpoint.

The display flashes the economy setpoint.

Press the PROG key to enter the economy
temperature.

Summary of Contents for Chronotherm T4600

Page 1: ...d status Attractive contemporary styling Temperature range selectable between 45 F to 80 F 7 C to 27 C Simple pushbutton programming Weekday weekend 5 2 programming for permanent home normal operation Optional unoccupied low limit setting for seasonal residence cottage operation Temporary temperature override Program override for seasonal temperature setback Permanent override for seasonal shutdow...

Page 2: ...itions are changed TRADELINE Models TRADELINE models are selected and packaged to provide ease of stocking ease of handling and maximum replacement value TRADELINE Models Available T4600A Chronotherm Electronic Programmable Line Voltage Thermostat with spst switching makes heating circuit on temperature fall Features TRADELINE pack Temperature Ratings Operating Range 22 to 104 F 30 to 40 C Control...

Page 3: ... AS REQUIRED SPECIAL SERVICE CO ALR SOLDERLESS CONNECTORS MUST BE USED WHEN CONNECTING ALUMINUM CONDUCTORS OTHERWISE A FIRE HAZARD CAN RESULT THERMOSTAT BREAKS HEATING CIRCUIT ON TEMPERATURE RISE THERMOSTAT IS DESIGNED TO BE USED WITH APPLIANCES EQUIPPED WITH A LIMIT CONTROL T4600A ELECTRONIC LINE VOLTAGE THERMOSTAT ELECTRIC HEATER BLACK BLACK M4788 Fig 2 T4600A Typical wiring connections PROG AUT...

Page 4: ...ad per thermostat must not exceed 2500W 8 ft of baseboard heater 2 Disconnect power to the thermostat to prevent electrical shock or equipment damage All wiring must comply with local electrical codes and ordinances 3 Remove the T4600 cover at the top or bottom edge with a slotted screwdriver 4 Remove the old thermostat from the wall taking care not to damage the wiring insulation 5 Check the old ...

Page 5: ...ramming by holding down the PROG key for four seconds or until the display shows the room temperature IMPORTANT The T4600 uses the time and day that was last in its memory as the basis for control Unexpected thermostat operation can occur when the clock is not set properly ACTIVITY RESULT DISPLAY SET THE TIME AND DAY Hours Press and release the PROG key The hour display flashes in the 12 hour AM P...

Page 6: ...ease the PROG key to enter the time PROGRAM THE DAY SETBACK AND AFTERNOON RECOVERY TIMES Day Setback Press the up and down keys to select the desired day setback time The display flashes the DAY setback time Afternoon Recovery Press the up and down keys to select the desired afternoon recovery time The display flashes the afternoon recovery warm up time Press and release the PROG key to enter the ...

Page 7: ... 20 C Let the system operate for at least one hour and adjust the setting as necessary M4657 AUTO MAN TEMPOR NIGHT DAY Su Mo Tu We Th Fr Sa AM PM ACTIVITY RESULT DISPLAY Set Cottage Programs CAUTION Before using the COTTAGE program make sure there are no water pipes along outside walls sealed in cabinets or installed in a manner that can cause them to freeze when the room temperature falls to 45 F...

Page 8: ...rdon Baker Road North York Ontario M2H 3N7 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www honeywell com yourhome 68 0168 3 J S Rev 2 99 The electrical power industry of the U...