background image

69-1085

4

CT2700 AN ELECTRONIC ROUND

 

 PROGRAMMABLE THERMOSTAT

All wiring must comply with local electrical codes and
ordinances. If unsure about household wiring procedures,
call your local heating and air conditioning contractor.

Refer to the masking tape labels you placed on wires
when you removed your old thermostat.

Match the letter of your old thermostat wire with the
terminal of the corresponding letter on your new

thermostat. Refer to Fig. 7.

M12529

ALTERNATE

MOUNTING

SCREW HOLE

MOUNTING

SCREW

HOLE

MOUNTING
SCREW HOLE

ROUTE WIRING AS
SHOWN THROUGH
ENTRANCE 
HOLE

WIRING ENTRANCE HOLE

ALTERNATE MOUNTING

SCREW HOLE

W

Y

G

R

C

O

O

L

O

FF

HE

AT

FAN

ON

A

U

T

O

Fig. 7. CT2700 wallplate wiring connections.

NOTE:

To ensure proper mounting of the thermostat,
restrict all wiring to the left side of the terminals.

Loosen the terminal screws and slip each wire
beneath its matching terminal. The shape of the

terminals permit insertion of straight or wraparound
connections. See Fig. 8. Tighten the terminals.

M12537

FOR WRAPAROUND, STRIP 
7/16 INCHES (11 mm)

FOR STRAIGHT INSERTION,
STRIP 5/16 INCHES (8 mm)

Fig. 8. CT2700 methods for wiring connection.

Plug the hole in the wall with insulation to help
prevent drafts from adversely affecting thermostat

operation.

ADJUST FAN OPERATION SWITCH

The thermostat fan operation switch, labeled fuel switch in
Fig. 9, is set at the factory in the F (gas/oil fuel) position.
This is the correct setting for most systems. If this system
is an electric heat system, set the switch to the E (electric)
position. The E setting allows the fan to turn on immedi-
ately with the heating or cooling equipment in a system
where the G terminal is connected.

M12531

FUEL SWITCH

F

E

Fig. 9. Fuel switch, rear view of thermostat.

MOUNT THERMOSTAT TO

 WALLPLATE

Align the tab and connector pins at the top of the
thermostat with the wallplate. See Fig. 10.

M12530

DASHED LINES
INDICATE TABS 
ON BACK OF 
THERMOSTAT

ALIGN TABS/PINS AT TOP 
OF THERMOSTAT WITH 
WALLPLATE CONNECTOR.

A

B

PRESS THERMOSTAT CASE
STRAIGHT ON TO LATCH.

Set

C

O

O

L

O

FF

HE

AT

FAN

ON

A

U

T

O

C

O

O

L

O

FF

HE

AT

FAN

ON

A

U

T

O

Set

Fig. 10. Mounting thermostat to wallplate.

Summary of Contents for An Electronic Round CT2700

Page 1: ...ructions in this manual Direct any questions concerning the application of this thermostat to Honeywell Customer Assistance at 1 800 468 1502 Monday Friday 7 00 a m 5 30 p m Central time RECYCLING THERMOSTAT If this thermostat is replacing a control that contains mercury in a sealed tube do not place your old control in the trash Contact your local waste management authority for instructions regar...

Page 2: ...t need labeling Wrap wires around a pencil to keep them from falling back into the wall as shown in Fig 2 WIRES THROUGH WALL OPENING M5136 Fig 2 Wrapping wires around pencil Replacing Clock With C or C1 Clock Terminals If you are replacing a Honeywell Chronotherm Thermo stat you may find one or two wires that go to the C or C1 clock terminals on the Chronotherm Thermostat wiring wallplate Do not a...

Page 3: ...s plaster or wood drill 7 32 inch holes Gently tap provided anchors into the drilled holes until flush with the wall Reposition the decorator cover plate and wallplate pulling wires through the wiring opening Loosely insert the mounting screws into the holes Level for appearance only the thermostat functions properly even when not level Tighten the mounting screws 4 WIRE WALLPLATE TERMINALS The CT...

Page 4: ...s See Fig 8 Tighten the terminals M12537 FOR WRAPAROUND STRIP 7 16 INCHES 11 mm FOR STRAIGHT INSERTION STRIP 5 16 INCHES 8 mm Fig 8 CT2700 methods for wiring connection Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation 5 ADJUST FAN OPERATION SWITCH The thermostat fan operation switch labeled fuel switch in Fig 9 is set at the factory in ...

Page 5: ...the cooling temperature settings NOTE To exit the sequence at any time press until End is displayed 1 Set Current Time a Press b Press or to set current time If you wish to change the preprogrammed time tempera ture settings follow steps 2 through 6 If not press the key until End is displayed or the thermostat will automatically return to normal operational mode within five minutes 2 Set WAKE Time...

Page 6: ... to raise the temperature setting above the room temperature The cooling equipment should shut down Fan Slide the System switch to OFF and the Fan switch to ON The fan should run continuously CUSTOMIZE YOUR THERMOSTAT The following instructions provide the information neces sary to change the heating cycle rate to match your heating equipment choose Fahrenheit F or Celsius C and 12 or 24 hour cloc...

Page 7: ...eat gravity 1 Symptom Possible Cause Corrective Action Heating cooling equipment will not operate No AC power to thermostat Check power to heating cooling equipment On Off switch Fuse or circuit breaker Loose 24V connection At thermostat at furnace air conditioner Incorrect wiring check appropriate wiring diagram Thermostat inoperative See checkout section System switch on thermostat in wrong posi...

Page 8: ...mer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above Honeywell shall not be liable for any loss or damage of any kind including any incidental or consequential damages resulting directly or indirectly from any breach of any warranty expressed or implied or any other failure of this product Some states do not allow the exclusion or limitation o...

Reviews: