System Communication and Operation
6-5
ADEMCO Contact ID
®
ADEMCO and Robofon Contact ID
®
Reporting takes the following format:
CCCC(CCCCCC) Q EEE GG ZZZ where:
CCCC(CCCCCC) =4-digit or 10-digit Customer (subscriber) ID
Q = 1-digit Event qualifier, where: E = new event , and R = restore
EEE =3-digit (hexadecimal) Event code (see central office receiver manual for a
complete list of event codes)
GG = 2-digit Partition Number (system messages show “00”)
ZZZ = 3-digit Zone/contact ID number reporting the alarm, or user
number for open/close reports. System status messages (AC
Loss, Walk Test, etc.) contain zeroes in the ZZZ location.
TABLE OF CONTACT ID EVENT CODES
Code
Definition
100
Medical Emergency (sent upon zone type
15 faults)
110 Fire
Alarm
121 Duress
122
Alarm, 24-hour Silent
123
Alarm, 24-hour Audible
131 Alarm,
Perimeter
132 Alarm,
Interior
134 Alarm,
Entry/Exit
135
Alarm, Zone Type 5
143
Alarm, Expansion Module
144
Sensor Tamper Alarm
145
ECP Module Cover Tamper Alarm
146
Silent Burglary Alarm
150
Alarm, 24-Hour Auxiliary/Monitor zone
162 Gas
Alarm
301
AC Mains Power
302
Low System Battery/Battery Test Fail
305
System Reset (Log only)
309 Battery
Fail
321
Siren Supervision Failure
333
Trouble, Expansion Mod. Supervision
341
Trouble, ECP Cover Tamper
344
RF Receiver Jam Detect
351
Telecom Line Fault
353
Alternative Comm. Media Trouble
354
Failure to Communicate (log only)
373
Fire Loop Trouble
374
Exit Error Alarm
380
Trouble Zone Type 5
381
RF Sensor Supervision
382 Supervision
Auxiliary Wired Zone
(sent after code 333 is sent)
383
RF Sensor Tamper and Double-Balanced
Zone Tamper
384
RF Sensor Low-battery
Code
Definition
393
Clean Me (ESL smoke detectors only)
401
Disarmed, Armed AWAY,
Armed MAXIMUM
403
Scheduled Arm/Disarm AWAY
406
Cancel by User
407
Remote Arm/Disarm (Downloading)
408
Quick Arm AWAY
409
Keyswitch Arm/Disarm AWAY
412
Successful Download/Access (see field
*53 to enable code)
441 Disarmed/Armed
STAY/INSTANT,
Quick-Arm STAY/INSTANT
442
Keyswitch Arm/Disarm STAY
461
Wrong Code Entry (keypad lockout
activated; see field *188 to enable code)
570 Bypass
601
Manually Triggered Dialer Test
602
Periodic Dialer Test
606
Audio Alarm Verification (AAV) to Follow
607
Walk Test Entered/Exited
623
Event Log 80% Full
625
Real-Time Clock was Changed (log only)
626
Time/Date Inaccurate (see field *53 to
enable code)
627
Program Mode Entry (log only)
628
Program Mode Exit (log only)
641
Senior Watch Trouble (up and about)
750 -
789
Reserved for Configurable Zone Type
report codes (check with central station
when using these codes)
801
Override Tamper Arming (log only)
802
Override Low Battery Arming (log only)
803
Override AC Loss Arming (log only)
804
Override Supervision Arming (log only)
999
Zone Type 23 Fault (log only)
Summary of Contents for ADEMCO VISTA-12A
Page 2: ...ii ...
Page 26: ...Installation and Setup Guide 2 20 ...
Page 82: ...Installation and Setup Guide 5 26 ...
Page 98: ...Installation and Setup Guide 7 4 ...
Page 104: ...Installation and Setup Guide 8 6 ...
Page 108: ...Installation and Setup Guide 9 4 ...