- 3 -
VIEWING THE KEYPAD ADDRESS
Press and hold down the
and
keys at the same
time for 3 seconds. The current address is displayed. No key
entry is allowed. Press the
key to exit or wait 30
seconds to exit viewing mode.
FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
symbols (fire, police, personal emergency) is provided. These
labels can be placed next to the keys to identify each key's
function for the end user (as determined by the control panel's
capability and programming; see the control's instructions).
61x2-FUNCT-KEY-LBLS-07-19-13_1A
PANIC ALARM STICKERS
800-13067-02
6152V VOICE STATUS
Refer to the control panel’s programming guide for information on programming zone descriptors. The following table provides a list of
supported zone descriptors and index entries. If using zone descriptors is not supported by this keypad, turn the Voice Chime mode OFF.
Zone Descriptors and Index Entries
ALARM
002 DOOR
057 KITCHEN
105 PATIO
146 UPSTAIRS
207
ATTIC
009 EMERGENCY
067 LAUNDRY
106 POLICE
151 UTILITY
208
BABY
012 EXIT
071 LIBRARY
109 POOL
152 WINDOW
217
BACK
013 FIRE
079 LIVING
113 ROOM
162 YARD
223
BASEMENT 016 FLOOR
080 MAIN
122 SHED
168 ZONE
225
BATHROOM 017 FRONT
085 MASTER
123 SHOP
170 1ST
228
BEDROOM
019 GARAGE
089 MEDICAL
125 SIDE
173 2ND
230
CLOSED
040 GUN
094 MOTION
131 SLIDING
175 3RD
232
DEN
050 HALL
095 OFFICE
136 SMOKE
176
DETECTOR 052 HOUSE
099 OPEN
138 STORAGE
185
DINING
053 INSIDE
101 PANIC
144 SUPERVISED
190
TROUBLESHOOTING
Symptoms Cause
Possible
Remedies
•
Keypad displays “OC”
•
Keypad Display is Blank
•
Keypad stops beeping after 5 keystrokes
Keypad is not
Communicating with
the control panel.
Check connections on Yellow and Green wires.
Verify the keypad device address is programmed in the control panel.
Verify the keypad address is entered in the keypad.
Make sure the keypad address is not duplicated in the system
SPECIFICATIONS
6152
6152V
Physical:
4.88"H x 6.934"W x 1.02"D
4.88"H x 6.934"W x 1.02"D
Displays:
Fixed-Word LCD (backlit).
Fixed-Word LCD (backlit).
Sounder:
Piezo-electric [fire alarm is loud, pulsing single tone; (all
Keypads) burglary alarm is loud, continuous, dual tone].
Speaker [fire alarm is loud, pulsing single tone; (all
Keypads) burglary alarm is loud, continuous, dual tone].
Voltage:
12VDC (power-limited)
12VDC (power-limited)
Current:
70mA (ARMED LED lit, LCD backlight and sounder on),
reduces to 40mA when control is operating in standby
mode (backlight off).
190mA (ARMED LED lit, LCD backlight and sounder
on), reduces to 60mA when control is operating in
standby mode (backlight off).
NFPA-72:
Compliant.
Compliant.