– 5 – 

 

 

e. 

Serial Number

 

    |    |    |    |    |    |     

Serial Number 

       

Loop

 

56 

Manually enter the 7-digit serial number printed on 
the label of the transmitter.  

Press the [

] key to move to the “Loop” position, 

and then enter the loop number.  
To delete an existing serial number, enter 0 in the 
loop number field. The serial number will change to 
0's. If 0 was entered in error, simply re-enter the 
loop number or press [#], the serial number will 
return to the display. 

Press [

] to advance. 

f. 

Response Time

 

       

56 

Applies only to hardwire zones 1-8. 

0

 = 10mSec 

 

1

 = 350mSec    

2

 = 700mSec 

3

 = 1.2 seconds 

Press [

] to advance. 

g. 

Configuration 

 

(Hardwire Type) 

       

56 

Applies only to hardwire zones 1-8. 

0

 = EOL 

1

 = NC 

2

 = NO 

3

 = zone doubling (ZD) (V20P/V21iP only) 

4

 = double-balanced (DB) (V20P/V21iP only) 

Press [

] to advance. 

h. 

Library 

 

(Zone Descriptor) 

                            

word 1 

word 2 

word 3 

82 

For each descriptor word for this zone, enter the 
3-digit number from the Vocabulary list. 

(see Library list of descriptors on the back page or 
in the controls’ Programming Guide) 

Press [

] to return to the Zone Number prompt to 

program the next zone or advance to the Quit menu.

 

Menu 7: Quit Menu Mode Programming 

NOTES: 

Use this menu to exit Menu mode programming. After 
exiting, the “Communicating” message appears 
briefly, indicating the control is being updated with the 
programmed information. 

 

QUIT QUICK 

 

PROGRAMMING MODE 

 
1 – Exit – Allow Re-entry 
2 – Exit – Block Re-entry 
3 – Back to 1st Page 

 

Quit Menu 

Programming Option 

Entries 

Field

Notes 

a. 

Exit – Allow Re-Entry

 

99 

Exits program mode and allows

 

re-entry by: 

Installer Code + 8 0 0, or pressing [

] and [#] at the 

same time within 50 seconds of powering up 

b.

  Exit – Block Re-Entry

 

98 

Exits programming mode and prevents re-entry by:  
Installer Code + 8 0 0.   

To reenter programming mode, the system must be 
powered down, then powered up. Then press [

and [#] at the same time within 50 seconds of 
powering up.  

For other 

98 program mode lockout options, see 

field 

88 in

 

standard control panel programming 

mode (installer code + 800). 

c. 

Back to 1st Page

 

-- 

Press 3 to return to the first page of Menu mode 
programming. 

 

Summary of Contents for 6162

Page 1: ...P 4 16 VISTA 15P 9 16 VISTA 20P 9 16 VISTA 21iP 3 16 Navigation Keys for Menu Mode Programming Key Function Settings Key Enter and exit Menu mode programming Night Stay Advance to the next page Advance to the next field If at the last field on a page it advances to the next page Goes to the previous field If at the first field goes to the previous page SETTINGS KEY ENTER MENU MODE PROGRAMMING CLEA...

Page 2: ... up to 4 digits 0 9 B C D AWAY for E STAY for F 43 e Primary Account Number Partition 2 See primary account number part 1 for entries 45 f Secondary Account Number Partition 1 See primary account number part 1 for entries 44 g Secondary Account Number Partition 2 See primary account number part 1 for entries 46 Menu 2 Enabling Reporting Options for ADEMCO Contact ID reporting only NOTES This menu ...

Page 3: ...ntry exit delays alarm sounding timeouts installer code and enable the auto stay option To program other options use standard control panel programming mode installer code 800 Refer to the field number column for the respective programming field in standard programming mode Timing Misc P1 P2 Exit Delay 60 60 Entry 1 Delay 30 30 Entry 2 Delay 30 30 Alarm Sound Time 4M Fire Snd Timeout N Installer C...

Page 4: ...g line is replaced by the serial number entry line S N Axxx xxxx Loop x Zone Programming 01 Type 09 Fire Send Report Y Part 1 Input Type Hardwired Resp 350mS Config EOL Library 000 000 000 Disp xxxxxxxxxxxxxxxx Zone Programming Programming Option Entries Field Notes a Zone Type 56 Enter the 2 digit Zone Type from the table below 00 Not used 07 24 Hr Audible 20 Arm STAY 01 Entry exit 1 08 24 Hr Aux...

Page 5: ...n the back page or in the controls Programming Guide Press to return to the Zone Number prompt to program the next zone or advance to the Quit menu Menu 7 Quit Menu Mode Programming NOTES Use this menu to exit Menu mode programming After exiting the Communicating message appears briefly indicating the control is being updated with the programmed information QUIT QUICK PROGRAMMING MODE 1 Exit Allow...

Page 6: ... 125 MEDICAL 126 MEDICINE 128 MONEY 129 MONITOR 130 MOTHERS 131 MOTION 132 MOTOR N 134 NORTH 135 NURSERY O 136 OFFICE 138 OPEN 139 OPENING 140 OUTSIDE 142 OVERHEAD P 143 PAINTING 144 PANIC 145 PASSIVE 146 PATIO 147 PERIMETER 148 PHONE 150 POINT 151 POLICE 152 POOL 153 POWER R 155 RADIO 156 REAR 157 RECREATION 159 REFRIGERATION 160 RF 161 RIGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167...

Reviews: