– 3 – 

 

Menu 3: Enabling System Reports (for ADEMCO Contact ID

®

 reporting only) 

 

NOTES: 

This menu lets you enable various system reports if 
ADEMCO Contact ID

®

 format is being used by 

selecting yes or no for each report. If another report 
format is desired, use standard control panel 
programming mode (installer code + 800) to program 
these reports. Refer to the field number column for the 
respective programming field in standard programming 
mode. 

 

System Reports 
RF Jam 

Cancel 

Log Full 

 

 

Exit Error  

 

  

P1 

P2 

P3 

Open Report  N 

Close Away  

Close Stay  

 

System Reports 

Programming Option 

Event 

Field

Notes 

a. 

RF Jam Report

 

      

 

22 

To enable/disable a report: 

= No

 

 

1

 = Yes 

To toggle the entry, use the 

D

 key. 

Dashed boxes:

 Indicates the entry is available 

only for partitioned systems (ex. VISTA-20P, 
VISTA-21iP). 

 

b. 

Cancel Report

 

       

68 

c. 

Event Log Full Report

 

       

89 

d. 

Exit Error Report

 

       

59 

e. 

Open Report

 

       

      

      

Part 1 

Part 2 

Part 3

65 

f. 

Close Away Report 
(Arm Away)

 

       

      

      

Part 1 

Part 2 

Part 3 

66 

g. 

Close Stay Report 
(Arm Stay)

 

       

      

      

Part 1 

Part 2 

Part 3 

66 

 

 

Menu 4: Timing and Miscellaneous Options 

 

NOTES: 

This menu lets you set entry/exit delays, alarm 
sounding timeouts, installer code, and enable the auto-
stay option. To program other options, use standard 
control panel programming mode (installer code + 800). 
Refer to the field number column for the respective 
programming field in standard programming mode. 

 

Timing / Misc 

P1 

P2 

Exit Delay 

60 

60 

Entry 1 Delay 

30 

30 

Entry 2 Delay 

30 

30 

Al ar m So un d Ti me : 

4M 

Fire Snd. Timeout   

 N 

Installer Code 

   xxxx 

Auto Stay: 

Part 1 & 2 

 

Timing and Miscellaneous Options 

Scroll Backward: 

Use the 

C

 key; 

Scroll Forward:

 Use the 

D

 key. 

Dashed boxes

: Indicates the entry is available only for partitioned systems (ex. VISTA-20P, VISTA-21iP).

 

Programming Option 

Entries 

Field

Notes 

a. 

Exit Delay

 

   |            |       

Part. 1 

Part. 2 

34 

00 - 96

 = 0 - 96 seconds  

 

97

 = 120seconds 

 

SIA Controls: Entries less than 45 result in 45-sec. delay. 

b. 

Entry Delay 1

 

   |             |       

Part. 1 

Part. 2

 

35 

00 - 96

 = 0 - 96 seconds  

98

 = 180seconds 

97

 = 120seconds 

99

 = 240seconds 

SIA Controls: Entries less than 30 result in 30-sec. delay. 

c. 

Entry Delay 2

 

   |             |         

Part. 1 

Part. 2 

36 

See Entry Delay 1 for entries. 

d. 

Alarm Sounder (Bell) 
Timeout 

 

       

 

33 

0

 = none 

3

 = 12 min 

1

 = 4 min  

4

 = 16 min 

2

 = 8 min 

e.

 Fire Alarm Sound 

Timeout 
[Fire Snd. Timeout] 

       

32 

0

 = Yes - sound stops at timeout set in field 

33  

1

 = No - no timeout

 

f.

 Installer 

Code

 

    |    |    |  

 

  

 

 

20 

4 digits, 

0000-9999

 

g. 

Auto-Stay

 

        

84 

0

 = no  

2

 = part. 2 only 

1

 = part. 1 only 

3

 = part. 1 & part 2 

 

Summary of Contents for 6162

Page 1: ...P 4 16 VISTA 15P 9 16 VISTA 20P 9 16 VISTA 21iP 3 16 Navigation Keys for Menu Mode Programming Key Function Settings Key Enter and exit Menu mode programming Night Stay Advance to the next page Advance to the next field If at the last field on a page it advances to the next page Goes to the previous field If at the first field goes to the previous page SETTINGS KEY ENTER MENU MODE PROGRAMMING CLEA...

Page 2: ... up to 4 digits 0 9 B C D AWAY for E STAY for F 43 e Primary Account Number Partition 2 See primary account number part 1 for entries 45 f Secondary Account Number Partition 1 See primary account number part 1 for entries 44 g Secondary Account Number Partition 2 See primary account number part 1 for entries 46 Menu 2 Enabling Reporting Options for ADEMCO Contact ID reporting only NOTES This menu ...

Page 3: ...ntry exit delays alarm sounding timeouts installer code and enable the auto stay option To program other options use standard control panel programming mode installer code 800 Refer to the field number column for the respective programming field in standard programming mode Timing Misc P1 P2 Exit Delay 60 60 Entry 1 Delay 30 30 Entry 2 Delay 30 30 Alarm Sound Time 4M Fire Snd Timeout N Installer C...

Page 4: ...g line is replaced by the serial number entry line S N Axxx xxxx Loop x Zone Programming 01 Type 09 Fire Send Report Y Part 1 Input Type Hardwired Resp 350mS Config EOL Library 000 000 000 Disp xxxxxxxxxxxxxxxx Zone Programming Programming Option Entries Field Notes a Zone Type 56 Enter the 2 digit Zone Type from the table below 00 Not used 07 24 Hr Audible 20 Arm STAY 01 Entry exit 1 08 24 Hr Aux...

Page 5: ...n the back page or in the controls Programming Guide Press to return to the Zone Number prompt to program the next zone or advance to the Quit menu Menu 7 Quit Menu Mode Programming NOTES Use this menu to exit Menu mode programming After exiting the Communicating message appears briefly indicating the control is being updated with the programmed information QUIT QUICK PROGRAMMING MODE 1 Exit Allow...

Page 6: ... 125 MEDICAL 126 MEDICINE 128 MONEY 129 MONITOR 130 MOTHERS 131 MOTION 132 MOTOR N 134 NORTH 135 NURSERY O 136 OFFICE 138 OPEN 139 OPENING 140 OUTSIDE 142 OVERHEAD P 143 PAINTING 144 PANIC 145 PASSIVE 146 PATIO 147 PERIMETER 148 PHONE 150 POINT 151 POLICE 152 POOL 153 POWER R 155 RADIO 156 REAR 157 RECREATION 159 REFRIGERATION 160 RF 161 RIGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167...

Reviews: