background image

3800g/3800gHD/3800gPDF User’s Guide

6 - 3

Scan the 

Hands Free Time-Out

 bar code, then scan the time-out duration 

(from 0-300,000 milliseconds) from the inside back cover, and 

Save

.   

Default = 

5,000 ms.

Hands Free Time-Out

Summary of Contents for 3800g

Page 1: ... 3800g 3800gHD 3800gPDF General Purpose Handheld Linear Imager User s Guide ...

Page 2: ... omissions con tained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied repro duced or translated into another language without the prior written consent of Honeywell 2006 2008 Honeywell ...

Page 3: ...d Wedge Connection 1 5 Laptop Direct Connect 1 6 Connecting the Imager with RS 232 Serial Port 1 6 IBM 4683 Ports 5B 9B and 17 Interface 1 7 Reading Techniques 1 8 Reading PDF417 Bar Codes 1 8 Resetting the Standard Product Defaults 1 9 Chapter 2 Terminal Interfaces Terminal ID 2 1 Supported Terminals 2 2 Keyboard Country 2 4 Keyboard Style 2 5 Keyboard Modifiers 2 6 RS 232 Baud Rate 2 8 RS 232 Wo...

Page 4: ... Mode 3 4 Hands Free Time Out 3 4 Reread Delay 3 5 User Specified Reread Delay 3 5 Centering Window 3 5 Output Sequence Overview 3 8 Output Sequence Editor 3 9 Require Output Sequence 3 9 Output Sequence Editor 3 11 Require Output Sequence 3 11 Multiple Symbols 3 12 No Read 3 12 Video Reverse 3 13 Chapter 4 Data Editing Prefix Suffix Overview 4 1 To Add a Prefix or Suffix 4 1 To Clear One or All P...

Page 5: ...ctions 5 2 Data Format Editor Commands 5 2 Data Format Editor 5 4 Data Formatter 5 5 Alternate Data Formats 5 5 Chapter 6 Secondary Interface 3800g Models 6 1 Enabling the Secondary Interface 6 1 Secondary RS 232 Connection 6 1 Secondary Trigger Mode 6 2 Hands Free Time Out 6 2 Chapter 7 Symbologies Introduction 7 1 All Symbologies 7 2 Message Length 7 2 Codabar 7 3 Codabar Start Stop Characters 7...

Page 6: ... Code Page 7 10 Straight 2 of 5 Industrial three bar start stop 7 11 Straight 2 of 5 Industrial Message Length 7 11 Straight 2 of 5 IATA two bar start stop 7 11 7 11 Straight 2 of 5 IATA Message Length 7 12 Matrix 2 of 5 7 12 Matrix 2 of 5 Message Length 7 12 Code 11 7 13 Check Digits Required 7 13 Code 11 Message Length 7 14 Code 128 7 14 ISBT 128 Concatenation 7 14 Code 128 Message Length 7 15 C...

Page 7: ...E0 Number System 7 21 UPC E0 Addenda 7 21 EAN JAN 13 7 21 EAN JAN 13 Check Digit 7 22 EAN JAN 13 Addenda 7 22 EAN JAN 13 Addenda Required 7 22 EAN JAN 13 Addenda Separator 7 23 ISBN Translate 7 23 EAN JAN 8 7 23 EAN JAN 8 Check Digit 7 24 EAN JAN 8 Addenda 7 24 EAN JAN 8 Addenda Required 7 24 EAN JAN 8 Addenda Separator 7 25 MSI 7 25 MSI Check Character 7 25 MSI Message Length 7 26 Plessey Code 7 ...

Page 8: ... 3800gPDF only 7 34 MicroPDF417 Message Length 7 34 GS1 Composite Codes 7 34 UPC EAN Version 7 35 GS1 Composite Code Message Length 7 35 GS1 Emulation 7 35 Chapter 8 Interface Keys Keyboard Function Relationships 8 1 Supported Interface Keys 8 3 Chapter 9 Utilities To Add a Test Code I D Prefix to All Symbologies 9 1 Show Software Revision 9 1 Show Data Format 9 1 Resetting the Standard Product De...

Page 9: ...cations 12 1 3800gHD 3800gPDF Product Specifications 12 2 Chapter 13 Maintenance Repairs 13 1 Maintenance 13 1 Cleaning the Device 13 1 Inspecting Cords and Connectors 13 1 Replacing the Interface Cable 13 2 Troubleshooting 13 2 Chapter 14 Customer Support Technical Assistance 14 1 Online Technical Assistance 14 1 Product Service and Repair 14 2 Online Product Service and Repair Assistance 14 2 Li...

Page 10: ...viii ...

Page 11: ...s However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati...

Page 12: ...ope The CE marking indicates compliance to 2004 108 EC EMC Directive with Standards EN55022 CLASS A EN55024 EN61000 3 2 EN61000 3 3 In addition complies to 2006 95 EC Low Voltage Directive when shipped with recommended power supply For CE related inquiries please contact Honeywell Imaging Mobility Europe BV Nijverheidsweg 9 5627 BT Eindhoven The Netherlands Honeywell shall not be liable for use of...

Page 13: ...aste and invites you to use the appropriate separate take back systems for product disposal If you need more information on the collection reuse and recycling systems please contact your local or regional waste administration You may also contact your supplier for more information on the environmental performances of this product Germany GS Mark Applicable if GS logo is marked on product to indica...

Page 14: ...tion Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure CB Scheme Certified to IEC60950 1 I T E Product Safety Solids and Water Protection The devices have a rating of IP41 immunity of foreign particles and dripping water tested to Standard EN60259 Patents Please refer to the product packaging for a list of paten...

Page 15: ...3800g Imager Identification Light Source Item Number Serial Number and Revision Compliance Label location ...

Page 16: ......

Page 17: ...hing you ordered is present Save the shipping container for later storage or shipping Check for damage during shipment Report damage immediately to the carrier who delivered the carton 3800g Models Note The Honeywell 3800g imager may be used with many interfaces which are described in this User s Guide Refer to the chart below to determine the models that can be used with your interface Refer to C...

Page 18: ...ditional USB programming and technical information refer to the Honey well USB Application Note available at www honeywell com aidc USB PC or Macintosh Keyboard The 3800g imagers are factory programmed for a USB interface If this is your interface and you do not need to modify the settings skip to Chapter 3 If you programmed the imager for a different terminal interface and you want to change to a...

Page 19: ...ollowing code to program the 3800g to emulate a regular RS 232 based Com Port If you are using a Microsoft Windows PC you will need to download a driver from the Honeywell website www honeywell com aidc The driver will use the next available Com Port number Apple Macintosh comput ers recognize the imager as a USB CDC class device and automatically uses a class driver Scanning the code below change...

Page 20: ...al to have the interface in effect Connecting the Imager When Powered by Host Keyboard Wedge An imager can be connected between the keyboard and PC as a keyboard wedge plugged into the serial port or connected to a portable data terminal The following is an example of a keyboard wedge connection 1 Turn off power to the terminal computer 2 Disconnect the keyboard cable from the back of the terminal...

Page 21: ...wedge ability Verify the imager operation by scanning a bar code from the Sample Symbols in the back of this manual The imager beeps once Keyboard Wedge Connection Scanning the bar code below allows operation of the 3800g as a keyboard wedge interface to an IBM PC AT with a U S keyboard If you programmed the imager for a different terminal interface and you want to change to an IBM PC AT and compa...

Page 22: ...o the terminal computer 2 Connect the appropriate interface cable to the imager Note For the imager to work properly you must have the correct cable for your type of terminal computer 3 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector to the port 4 Connect the power supply and plug into an outlet 5 Turn the terminal computer power back ...

Page 23: ...parity none 8 data bits 1 stop bit and adds a suffix of a CR LF Refer to page 2 8 for additional RS 232 configuration settings IBM 4683 Ports 5B 9B and 17 Interface Scan one of the following Plug and Play codes to program the 3800GX5E for IBM 4683 Port 5B 9B or 17 Note After scanning one of these codes you must power cycle the cash register RS 232 Interface IBM 4683 Port 5B Interface IBM 4683 Port...

Page 24: ...m from the unit To read a single bar code or multiple bar codes on a page or on an object hold the imager at an appropriate distance from the target pull the trigger and center the aiming beam on the bar code Reading PDF417 Bar Codes Note Applies to 3800gHD and 3800gPDF To read PDF417 bar codes with a PDF enabled 3800gHD 3800gPDF hold the trigger down and move the scanner up and down so the aiming...

Page 25: ... in your imager or you ve changed some options and want the factory settings restored scan the Stan dard Product Default Settings bar code below The Menu Commands starting on page 11 5 lists the factory default settings for each of the commands indicated by an asterisk on the programming pages Standard Product Default Settings ...

Page 26: ...1 10 3800g 3800gHD 3800gPDF User s Guide ...

Page 27: ...ual to program the imager for your terminal ID Scan Save to save your selection For example an IBM AT terminal has a Terminal ID of 003 You would scan the Terminal ID bar code then 0 0 3 from the Programming Chart inside the back cover of this manual then Save If you make an error while scanning the digits before scanning Save scan the Discard code on the Programming Chart scan the Terminal ID bar...

Page 28: ...77 3486 3482 3488 008 IBM 122 key 3180 024 IBM 122 key 3180 data entry keyboard 114 IBM DOS V 106 key PC Workstation 102 IBM SurePOS USB Handheld Imager 128 IBM SurePOS USB Tabletop Imager 129 IBM Thinkpad 360 CSE 340 750 097 IBM Thinkpad 106 IBM Thinkpad 365 755CV 003 I O 122 key 2676D 2677C 2677D 008 ITT 9271 007 Lee Data IIS 007 NEC 98XX Series 103 Olivetti M19 M200 001 Olivetti M240 M250 M290 ...

Page 29: ... 3 Factory default setting Telex 122 key 078 078A 79 80 191 196 1191 1192 1471 1472 1476 1477 1482 1483 046 USB PC Keyboard 124 USB Mac Keyboard 125 USB Com Port 130 USB HIDPOS 131 Supported Terminals Continued Terminal Model s Terminal ID ...

Page 30: ...try code below to program the keyboard for your country As a general rule the following characters are supported but need special care for countries other than the United States United States Denmark France Germany Austria Great Britain Italy Norway Spain Switzerland Belgium Finland ...

Page 31: ...Caps Lock is used when you normally have the Caps Lock key on Shift Lock is used when you normally have the Shift Lock key on not common to U S keyboards Automatic Caps Lock is used if you change the Caps Lock key on and off The software tracks and reflects if you have Caps Lock on or off AT and PS 2 only This selection can only be used with systems that have an LED which notes the Caps Lock statu...

Page 32: ...ons for ASCII control characters for values 00 1F Windows is the preferred mode All key board country codes are supported DOS mode is a legacy mode and it does not support all keyboard country codes New users should use the Windows mode Refer to Keyboard Function Relationships page 8 1 for CTRL ASCII Values Default Off Turbo Mode The imager sends characters to a terminal faster If the terminal dro...

Page 33: ...ered from a numeric keypad Default Off Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic Direct Connect Mode On Automatic Direct Connect Mode Off ...

Page 34: ...Length Data Bits Stop Bits and Parity Data Bits sets the word length at 7 or 8 bits of data per character If an applica tion requires only ASCII Hex characters 0 through 7F decimal text digits and punctuation select 7 data bits For applications which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 300 2400 600 1200 4800 ...

Page 35: ...haracter bit patterns for validity Default None 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 8 Data 1 Stop Parity None 8 Data 1 Stop Parity Even 8 Data 1 Stop Parity Odd ...

Page 36: ...de RS 232 Handshaking RS 232 handshaking is a set of rules concerning the exchange of data between serially communicating devices Default RTS CTS XON XOFF and ACK NAK Off RTS CTS On XON OFF Off RTS CTS Off XON XOFF On ACK NAK On ACK NAK Off ...

Page 37: ...o a good read indication All error and menu beeps are still audible Default On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the imager emits on a good read Default High for the 3800g Beeper Pitch Good Read The beeper pitch codes modify the pitch frequency of the beep the imager emits on a good read Default Medium On Off High Medium Off Low Low 1600 Hz Medium 2550 H...

Page 38: ...n be programmed from 1 9 The same number of beeps will be applied to the beeper and LED in response to a good read For example if you program this option to have five beeps there will be five beeps and five LED flashes in response to a good read The beeps and LED flashes are in sync with one another To change the number of beeps scan the bar code below and then scan a digit 1 9 bar code and the Sa...

Page 39: ...ds on page 11 4 When in manual trigger mode the imager scans until a bar code is read or until the trigger is released When in serial mode the imager scans until a bar code has been read or until the deactivate command is sent In serial mode the imager can also be set to turn itself off after a specified time has elapsed see Read Time Out which fol lows Read Time Out Use this selection to set a ti...

Page 40: ...her you may wish to have a continuous aiming beam on in order to properly aim the imager at one bar code Scan the Continuous Illumination On bar code to program the imager for this capability Once you have the aiming beam over the correct bar code pull the trigger to read the code Scan the Continuous Illumination Off bar code to turn off this feature Hands Free Time Out The Automatic Trigger and P...

Page 41: ...d Delay only works when in automatic trigger mode or presentation mode see page 3 4 User Specified Reread Delay If you want to set your own length for the reread delay scan the bar code below then set the delay from 0 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Centering Window Use the centering feature to narrow the imager s field of view so the imager rea...

Page 42: ...bar codes Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 for Left 60 for Right The figure below illustrates the percentage range from 1 to 100 Left of Centering Window Right of Centering Window Centering Off Centering On 20 30 90 80 40 60 70 10 0 100 ...

Page 43: ...de 3 7 Example If you have two bar codes next to one another and the centering window is set to 40 left edge and 60 right edge only the bar code that intersects that window will be decoded 20 30 90 80 40 60 70 10 0 100 Decoded bar code ...

Page 44: ...te You must hold the trigger while reading each bar code in a sequence To Add an Output Sequence 1 Scan the Enter Sequence symbol see Require Output Sequence page 3 9 2 Code I D On the Symbology Chart on page A 1 find the symbology to which you want to apply the output sequence format Locate the Hex value for that symbol ogy and scan the 2 digit hex value from the Programming Chart inside back cov...

Page 45: ...mit the output data to the host device When it s On Not Required the imager will attempt to get the output data to conform to an edited sequence but if it cannot the imager transmits all output data to the host device as is When the output sequence is Off the bar code data is output to the host as the imager decodes it Note This selection is unavailable when the Multiple Symbols Selection is turne...

Page 46: ...mand line is shown below SEQBLKsequence editor start command 62 code identifier for Code 39 9999 code length that must match for Code 39 9999 all lengths 41 start character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128 9999 all lengths 42 start character match for Code 128 42h B FF termination string for s...

Page 47: ...string for first code 6A code identifier for Code 128 0013 B Code 128 sample length 12 plus CR suffix 1 13 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 0012 C Code 93 sample length 11 plus CR suffix 1 12 43 start character match for Code 93 43h C FF termination string for third code Output Sequence Editor Require Output Sequence W...

Page 48: ...symbols once beeping if turned on for each read The imager attempts to find and decode new symbols as long as the trigger is pulled When this programming selection is turned Off the imager will only read the symbol closest to the aiming beam No Read With No Read turned On the imager sends an NR to the host if you pull and release the trigger without reading a code e g bad bar code If No Read is tu...

Page 49: ...used to allow the imager to read bar codes that are inverted The Off bar code below is an example of this type of bar code Note If additional menuing is required Video Reverse must be disabled to read the menu bar codes and then re enabled after menuing is completed On Off ...

Page 50: ...3 14 3800g 3800gHD 3800gPDF User s Guide ...

Page 51: ...h to alter the default settings Default prefix None Default suffix None A prefix or suffix may be added or cleared from one symbology or all symbologies You can add any prefix or suffix from the ASCII Conversion Chart Code Page 1252 on page A 2 plus Code I D and AIM I D You can string together several entries for several symbologies at one time Enter prefixes and suffixes in the order in which you...

Page 52: ... UPC only Step 1 Scan Add Suffix Step 2 Determine the 2 digit hex value from the Symbology Chart included in the for UPC Step 3 Scan 6 3 from the Programming Chart inside the back cover of this manual Step 4 Determine the hex value from the ASCII Conversion Chart Code Page 1252 on page A 2 for the CR carriage return Step 5 Scan 0 D from the Programming Chart inside the back cover of this manual St...

Page 53: ...ange is automatically saved To Add a Carriage Return Suffix to All Symbologies Scan the following bar code if you wish to add a carriage return suffix to all sym bologies at once This action first clears all current suffixes then programs a carriage return suffix for all symbologies Prefix Selections Add CR Suffix All Symbologies Add Prefix Clear One Prefix Clear All Prefixes ...

Page 54: ...mager is in keyboard wedge mode the scan code is con verted to a key code before it is transmitted Default Enable Intercharacter Interfunction and Intermessage Delays Some terminals drop information characters if data comes through too quickly Intercharacter interfunction and intermessage delays slow the transmission of data increasing data integrity Each delay is composed of a 5 millisecond step ...

Page 55: ...ion User Specified Intercharacter Delay An intercharacter delay of up to 495 milliseconds may be placed after the trans mission of a particular character of scanned data Scan the Delay Length bar code below then scan the number of milliseconds and the SAVE bar code using the Programming Chart inside the back cover of this manual Next scan the Character to Trigger Delay bar code then the 2 digit he...

Page 56: ...ogramming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 495 milliseconds may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of milliseconds and the SAVE bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intermessage Delay bar code then set t...

Page 57: ...l Code ID Universal Length 5 Universal Term ID Actual Code ID Actual Length 6 Universal Term ID Actual Code ID Universal Length 7 Universal Term ID Universal Code ID Actual Length 8 Universal Term ID Universal Code ID Universal Length If you have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code on page 5 4 To Add a Data...

Page 58: ... manual to save your entries Other Programming Selections Clear One Data Format This deletes one data format for one symbology If you are clearing the primary format scan 0 from the Programming Chart inside the back cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the alternate format you are clearing Scan the Terminal Type refer to the Supported Terminals Ch...

Page 59: ...he number of characters the cursor should be moved back F7 Move the cursor to the beginning of the data string Syntax F7 EA Move the cursor to the end of the data string Syntax EA Search Commands F8 Search ahead for xx character from current cursor position leaving cursor pointing to xx character Syntax F8xx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on...

Page 60: ...nd xx2 defines replacement characters continuing through zz1 and zz2 E5 Terminates character replacement Syntax E5 FE Compare character in current cursor position to the character xx If char acters are equal increment cursor If characters are not equal no format match Syntax FExx xx stands for the hex value for an ASCII code see ASCII Conversion Chart Code Page 1252 on page A 2 EC Check to make su...

Page 61: ...gle shot capability to scan one bar code using a different data format than your primary format When data formats are pro grammed see page 5 1 you must input whether you are programming the pri mary format or an alternate format numbered 1 2 or 3 An alternate format is initiated by scanning one of the 3 alternate format bar codes below The imager will scan the next bar code formatting the data wit...

Page 62: ...5 6 3800g 3800gHD 3800gPDF User s Guide ...

Page 63: ...ary interface settings in the imager s memory by scanning the Disable bar code below To re enable the secondary interface scan the Enable bar code Default Disable Secondary RS 232 Connection All communication parameters between the imager and terminal must match for correct data transfer through the serial port using RS 232 protocol Models Primary Interfaces Secondary Interfaces 3800G04E 3800G14E ...

Page 64: ...re off until a bar code is presented to the imager Then the LEDs turn on automatically to read the code Presentation Mode uses ambient light to detect the bar codes Hands Free Time Out The Automatic Trigger and Presentation Modes are referred to as hands free modes If the imager s trigger is pulled when using a hands free mode the imager changes to manual trigger mode You can set the time the imag...

Page 65: ...g 3800gHD 3800gPDF User s Guide 6 3 Scan the Hands Free Time Out bar code then scan the time out duration from 0 300 000 milliseconds from the inside back cover and Save Default 5 000 ms Hands Free Time Out ...

Page 66: ...6 4 3800g 3800gHD 3800gPDF User s Guide ...

Page 67: ...417 3800gHD 3800gPDF only Code 11 MSI Code 16K PDF417 3800gHD 3800gPDF only Code 39 Plessey Code Code 32 Pharmaceutical PARAF PosiCode Code 49 Straight 2 of 5 IATA two bar start stop Code 93 Straight 2 of 5 Industrial three bar start stop Code 128 Telepen UPC A EAN 13 with Extended Coupon Code Trioptic Code EAN JAN 8 UPC A GS1 DataBar Omnidirectional UPC E GS1 DataBar Limited Straight 2 of 5 IATA ...

Page 68: ...o set the same value for minimum and maximum length to force the imager to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09 Max length 20 EXAMPLE Decode only those bar codes with a count of 15 characters Min length 15 Max length 15 For a value other than the minimum and maximum message lengt...

Page 69: ...r check characters are created using different modulos You can pro gram the imager to read only Codabar bar codes with Modulo 16 check charac ters Default No Check Character No Check Character indicates that the imager reads and transmits bar code data with or without a check character When Check Character is set to Validate and Transmit the imager will only read Codabar bar codes printed with a c...

Page 70: ...er looks for a Codabar symbol having a D start character adjacent to a symbol having a D stop character In this case the two messages are concat enated into one with the D characters omitted Default Off Select Require to prevent the imager from decoding a single D Codabar sym bol without its companion This selection has no effect on Codabar symbols without Stop Start D characters No Check Characte...

Page 71: ...s identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Default Don t Transmit Code 39 Check Character No Check Character indicates that the imager reads and transmits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check cha...

Page 72: ...end This function allows the imager to append the data from several Code 39 bar codes together before transmitting them to the host computer When this func tion is enabled the imager stores those Code 39 bar codes that start with a space excluding the start and stop symbols and does not immediately trans mit the data The imager stores the data in the order in which the bar codes are read deleting ...

Page 73: ...xample V will be decoded as the ASCII character SYN and C will be decoded as the ASCII character Default Off NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 R B 2 2 B B R R b B r R ETX C DC3 S C 3 3 C C S S c C s S EOT D DC4 T D 4 4 D D T T d D t T ENQ E NAK U E 5 5 E E U U e E u U ACK F SYN V F 6 6 F F V V f F v V BEL G ETB W G 7 7 G G W W g G w W BS H CAN X H 8 8...

Page 74: ...e page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar code from the Programming Chart inside the back cover of this manual The data characters should then appear properly Interleaved 2 of 5 Default All Interleaved 2 of 5 Settings Interleaved 2 of 5 Check Digit No Check Digit indicates that the imager reads...

Page 75: ... digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Validate but Don t Transmit No Check Digit Validate and Transmit Minimum Message Length Maximum Message Length ...

Page 76: ...data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar c...

Page 77: ...Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 Straight 2 of 5 IATA two bar start stop Default All Code IATA 2 of 5 Settings Straight 2 of 5 IATA On Off Minimum Message Length Maximum Message Length On Off ...

Page 78: ...s 1 48 Minimum Default 4 Maximum Default 48 Matrix 2 of 5 Default All Matrix 2 of 5 Settings Matrix 2 of 5 Matrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Minimum Message Length Maximum Message Length On Off Minimum Message Length M...

Page 79: ...r s Guide 7 13 Code 11 Default All Code 11 Settings Code 11 Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 bar codes Default Two Check Digits On Off One Check Digit Two Check Digits ...

Page 80: ...d for communicating critical blood information in a uniform manner The use of ISBT formats requires a paid license The ISBT 128 Application Specification describes 1 the critical data elements for labeling blood products 2 the current recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neighboring...

Page 81: ...rogram is expecting If this is the case scan the bar code below select the code page with which the bar codes were created from the chart Code Page Mapping of Printed Bar Codes on page A 4 and scan the value and the SAVE bar code from the Programming Chart inside the back cover of this manual The data characters should then appear properly Code 128 Function Code Transmit By default Code 128 functi...

Page 82: ...eads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 On Off Original Telepen Output AIM Tele...

Page 83: ...ou to specify whether the check digit should be transmit ted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On On Off On Off Off On ...

Page 84: ... When Addenda Required is set to on the imager will only read UPC A bar codes that have addenda Default Not Required UPC A Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Required Off On ...

Page 85: ...th Extended Coupon Code Default On UPC E Default All UPC E Settings UPC E0 and UPC E1 Most U P C bar codes lead with the 0 number system For these codes use the UPC E0 selection If you need to read codes that lead with the 1 number sys tem use the UPC E1 selection Default On UPC E0 and Off UPC E1 On Off UPC E0 On UPC E0 Off UPC E1 On UPC E1 Off ...

Page 86: ...only read UPC E bar codes that have addenda Default Not Required UPC E0 and UPC E1 Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On Off On Not R...

Page 87: ...of the scanned data but the unit can be programmed so it will not transmit it Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Default All EAN JAN Settings Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On ...

Page 88: ...n EAN JAN 13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Addenda Required is set to on the imager will only read EAN JAN 13 bar codes that have addenda Default Not Required On Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required ...

Page 89: ...addenda When turned off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code on page 7 19 ISBN Translate This selection causes EAN 13 Bookland symbols to be translated into their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings Off On Off On ...

Page 90: ...On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 8 Addenda Required When Addenda Required is set to on the imager will only read EAN JAN 8 bar codes that have addenda Default Not Required On Off Off On 5 Digit Addenda Off 5 Digit Addenda On 2 Digit Addenda Off 2 Digit Addenda On Not Required Req...

Page 91: ...bar codes with Type 10 check characters Default Validate Type 10 but Don t Transmit When Check Character is set to Validate and Transmit the imager will only read MSI bar codes printed with the specified type check character and will transmit this character at the end of the scanned data When Check Character is set to Validate but Don t Transmit the unit will only read MSI bar codes printed with t...

Page 92: ...8 Plessey Code Default All Plessey Code Settings Plessey Code Plessey Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings Minimum Message Length Maximum Message Length On Of...

Page 93: ...D 3800gPDF User s Guide 7 27 GS1 DataBar Omnidirectional GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings On Off On Off ...

Page 94: ...lengths 4 74 Minimum Default 4 Maximum Default 74 China Post Code Default All China Post Code Settings China Post Code China Post Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length On Off Minimum ...

Page 95: ...ode Korea Post Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 PosiCode Default All PosiCode Settings On Off Minimum Message Length Maximum Message Length ...

Page 96: ...Length on page 7 2 for additional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Trioptic Code Trioptic Code is used for labeling magnetic storage media Note If you are going to scan Code 32 Pharmaceutical codes Trioptic Code must be off On Off A and B On No Limited A and B and Limited A On Limited B Off A and B and Limited B On Limited A Off Minimum Message Leng...

Page 97: ...lock F Message Length Scan the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Code 16K Default All Code 16K Settings On Off Minimum Message Length Maximum Message Length ...

Page 98: ...can the bar codes below to change the message length Refer to Message Length on page 7 2 for additional information Minimum and Maximum lengths 0 160 Minimum Default 1 Maximum Default 160 Code 49 Default All Code 49 Settings On Off Minimum Message Length Maximum Message Length ...

Page 99: ... 81 Minimum Default 1 Maximum Default 81 PDF417 3800gHD 3800gPDF only Default All PDF417 Settings PDF417 PDF417 Message Length Scan the barcodes below to change the message length Refer to Message Length page 7 2 for additional information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 On Off Minimum Message Length Maximum Message Length Off On Maximum Message Length Min...

Page 100: ...er to Message Length page 7 2 for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allow for the co existence of symbologies already in use Off On Maximum Message Length Minimum Message Length O...

Page 101: ...Maximum Default 2435 GS1 Emulation The imager can automatically format the output from any GS1 data carrier to emulate what would be encoded in an equivalent GS1 128 or GS1 DataBar symbol GS1 data carriers include UPC A and UPC E EAN 13 and EAN 8 ITF 14 GS1 128 and GS1 128 DataBar and GS1Composites If GS1 128 Emulation is selected the AIM Symbology Identifier will be reported as C1 If GS1 DataBar ...

Page 102: ...7 36 3800g 3800gHD 3800gPDF User s Guide ...

Page 103: ...inals that can be used with the imager Refer to page 2 6 enable Control ASCII mode Function Code HEX ASCII Value Full ASCII CTRL NUL 00 2 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS 1E 6 US 1F ...

Page 104: ...I CTRL column 6 apply to US only The following chart indicates the equivalents of these five characters for different countries Country Codes United States 6 Belgium 6 Scandinavia 8 9 6 France 8 6 Germany à 6 Italy 6 Switzerland 6 United Kingdom 6 Denmark 8 9 6 Norway 8 9 6 Spain 6 ...

Page 105: ...er CR Enter New Line BS 08 Reserved Reserved F16 HT 09 Tab Tab F17 LF 0A Reserved Reserved F18 VT 0B Tab Tab Tab Field Forward FF 0C Delete Delete Delete CR 0D CR Enter CR Enter Field Exit New Line SO 0E Insert Insert Insert SI 0F Escape Escape F19 DLE 10 F11 Reserved Error Reset DC1 11 Home Home Home DC2 12 Print Print F20 DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Backfield...

Page 106: ...rd LF 0A F18 Reserved VT 0B Tab Field Forward Field Forward FF 0C Delete Delete CR 0D Field Exit New Line SO 0E Insert Insert SI 0F Clear Erase DLE 10 Error Reset Error Reset DC1 11 Home Reserved DC2 12 Print Print DC3 13 Back Space Back Space DC4 14 Back Tab Back Field NAK 15 F19 Reserved SYN 16 F1 PF1 ETB 17 F2 PF2 CAN 18 F3 PF3 EM 19 F4 PF4 SUB 1A F5 PF5 ESC 1B F6 PF6 FS 1C F7 PF7 GS 1D F8 PF8 ...

Page 107: ...A N A N A BEL 07 New Line New Line New Line BS 08 N A N A N A HT 09 Tab Tab Tab LF 0A N A N A N A VT 0B Tab Tab Tab FF 0C N A N A Delete CR 0D New Line New Line New Line SO 0E N A N A Insert SI 0F Escape Escape Escape DLE 10 F11 F11 F11 DC1 11 Insert Insert Home DC2 12 F13 F13 Print DC3 13 Back Space Back Space Back Space DC4 14 Back Tab Back Tab Back Tab NAK 15 F12 F12 F12 SYN 16 F1 F1 F1 ETB 17 ...

Page 108: ...ake EOT 04 ALT break ENQ 05 CNTRL make ACK 06 CNTRL break BEL 07 RETURN BS 08 APPLE make HT 09 TAB LF 0A APPLE break VT 0B TAB FF 0C Del CR 0D RETURN SO 0E Ins Help SI 0F ESC DLE 10 F11 DC1 11 Home DC2 12 Prnt Scrn DC3 13 BACKSPACE DC4 14 LSHIFT TAB NAK 15 F12 SYN 16 F1 ETB 17 F2 CAN 18 F3 EM 19 F4 SUB 1A F5 ESC 1B F6 FS 1C F7 GS 1D F8 RS 1E F9 US 1F F10 DEL 7F BACKSPACE ...

Page 109: ... Scan the bar code below to output the current software revision unit serial num ber and other product information Show Data Format Scan the bar code below to show current data format settings Resetting the Standard Product Defaults If you aren t sure what programming options are in your imager or you ve changed some options and want the standard product default settings restored scan the Standard...

Page 110: ...Xpress Note If you have a unit capable of keyboard wedge mode scan the bar code below and the unit will communicate in RS 232 mode allowing it to work with Visual Xpress To convert the imager back to keyboard wedge communication cycle the power Note If you download new software into a unit the user programmed parameters are retained If you need to discard user programmed settings scan the Standard...

Page 111: ...bar codes and display the bar code data in a win dow Scan Data lets you send serial commands to the imager and receive imager response that can be seen in the Scan Data window The data dis played in the Scan Data window can either be saved in a file or printed Configure Configure displays the programming and configuration data of the imager The imager s programming and configuration data is groupe...

Page 112: ...l Xpress 5 When prompted select Save File and save the files to the c windows temp directory 6 Once you have finished downloading the file exit the web site 7 Using Explorer go to the c windows temp file and unzip the file you saved 8 Double click on Setup exe and follow the screen prompts to install the Visual Xpress program 9 If you ve selected the defaults during installation you can click on S...

Page 113: ...hat appear on the screen Menu Command Syntax Menu commands have the following syntax spaces have been used for clarity only Prefix Tag SubTag Data SubTag Data Tag SubTag Data Storage Prefix Three ASCII characters SYN M CR ASCII 22 77 13 Tag A 3 character case insensitive field that identifies the desired menu command group For example all RS 232 configuration settings are identified with a Tag of ...

Page 114: ...of the Data field the query applies only to the specific command identified by the Tag and SubTag fields Concatenation of Multiple Commands Multiple commands can be issued within one Prefix Storage sequence Only the Tag SubTag and Data fields must be repeated for each command in the sequence If additional commands are to be applied to the same Tag then the new command sequence is separated with a ...

Page 115: ... or on Example Example 3 What is the device s current setting for Codabar Coding Enable Enter cbrena Response CBRENA1 ACK This response indicates that the device s Codabar Coding Enable CBRENA is set to 1 or on Example Example 4 What are the device s settings for all Codabar selections Enter cbr Response CBRENA1 ACK SSX0 ACK CK20 ACK CCT1 ACK MIN2 ACK MAX60 ACK DFT ACK This response indicates that...

Page 116: ...Deactivate SYN U CR The imager scans until a bar code has been read until the deactivate command is sent or until the serial time out has been reached see Read Time Out on page 3 3 for a description and the serial command on page 11 8 Resetting the Standard Product Defaults If you aren t sure what programming options are in your imager or you ve changed some options and want the factory settings r...

Page 117: ...yboard TERMID 2 2 Program Keyboard Country USA KBDCTY0 2 4 Belgium KBDCTY1 2 4 Denmark KBDCTY8 2 4 Finland KBDCTY2 2 4 France KBDCTY3 2 4 Germany Austria KBDCTY4 2 4 Great Britain KBDCTY7 2 4 Italy KBDCTY5 2 4 Norway KBDCTY9 2 4 Spain KBDCTY10 2 4 Switzerland KBDCTY6 2 4 Keyboard Style Regular KBDSTY0 2 5 Caps Lock KBDSTY1 2 5 Shift Lock KBDSTY2 2 5 Automatic Caps Lock KBDSTY6 2 5 Emulate External...

Page 118: ...NPS0 2 7 Numeric Keypad On KBDNPS1 2 7 Auto Direct Conn Off KBDADC0 2 7 Auto Direct Conn On KBDADC1 2 7 Serial Port Connection RS 232 PAP232 1 7 Baud Rate 300 BPS 232BAD0 2 8 600 BPS 232BAD1 2 8 1200 BPS 232BAD2 2 8 2400 BPS 232BAD3 2 8 4800 BPS 232BAD4 2 8 9600 BPS 232BAD5 2 8 19200 BPS 232BAD6 2 8 38400 BPS 232BAD7 2 8 57600 BPS 232BAD8 2 8 115200 BPS 232BAD9 2 8 Selection Setting Indicates defa...

Page 119: ...ta 1 Stop Parity Even 232WRD5 2 9 8 Data 1 Stop Parity None 232WRD2 2 9 8 Data 1 Stop Parity Odd 232WRD8 2 9 RS 232 Handshaking RTS CTS Off 232CTS0 2 10 RTS CTS On 232CTS1 2 10 XON XOFF Off 232XON0 2 10 XON XOFF On 232XON1 2 10 ACK NAK Off 232ACK0 2 10 ACK NAK On 232ACK1 2 10 Output Selections Beeper Good Read Off BEPBEP0 3 1 On BEPBEP1 3 1 Beeper Volume Good Read Off BEPLVL0 3 1 Low BEPLVL1 3 1 M...

Page 120: ...d Delay No Delay DLYGRD0 3 3 Short Delay 500 ms DLYGRD50 0 3 3 Medium Delay 1000 ms DLYGRD10 00 3 3 Long Delay 1500 ms DLYGRD15 00 3 3 User Specified Good Read Delay Range 0 30 000 ms DLYGRD 3 3 Trigger Mode Manual Serial Trigger TRGMOD0 3 3 Read Time Out 0 300 000 ms 30 000 TRG STO 3 4 Automatic Trigger TRGMOD1 3 4 Presentation Mode TRGMOD3 3 4 Continuous Illumination On ILLAON1 3 4 Continuous Il...

Page 121: ...ow 60 DECRGT 3 6 Output Sequence Edi tor Enter Sequence SEQBLK 3 9 Default Sequence SEQDFT 3 9 Require Output Sequence Required SEQ_EN2 3 9 On Not Required SEQ_EN1 3 9 Off SEQ_EN0 3 9 Multiple Symbols On SHOTGN1 3 13 Off SHOTGN0 3 13 No Read On SHWNRD1 3 12 Off SHWNRD0 3 12 Video Reverse On VIDREV1 3 12 Off VIDREV0 3 12 Prefix Suffix Selections Add CR Suffix to All Symbologies VSUFCR 4 3 Prefix Ad...

Page 122: ...fault Data Format None DFMDF3 5 4 Enter Data Format DFMBK3 5 4 Clear One Data Format DFMCL3 5 4 Clear All Data Formats DFMCA3 5 4 Data Formatter Off DFM_EN0 5 5 On but Not Required DFM_EN1 5 5 On Required DFM_EN2 5 5 Alternate Data For mats 1 VSAF_1 5 5 2 VSAF_2 5 5 3 VSAF_3 5 5 Secondary Interface Selections Enabling the Second ary Interface Disable 2IF_EN0 6 1 Enable 2IF_EN1 6 1 Secondary RS 232...

Page 123: ...t CBRCK22 7 4 Codabar Concatena tion Off CBRCCT0 7 4 On CBRCCT1 7 4 Require CBRCCT2 7 4 Codabar Message Length Minimum 2 60 4 CBRMIN 7 5 Maximum 2 60 60 CBRMAX 7 5 Code 39 Default All Code 39 Settings C39DFT 7 5 Code 39 Off C39ENA0 7 5 On C39ENA1 7 5 Code 39 Start Stop Char Don t Transmit C39SSX0 7 5 Transmit C39SSX1 7 5 Code 39 Check Char No Check Char C39CK20 7 6 Validate But Don t Transmit C39C...

Page 124: ...9 Interleaved 2 of 5 Mes sage Length Minimum 2 80 4 I25MIN 7 9 Maximum 2 80 80 I25MAX 7 9 Code 93 Default All Code 93 Settings C93DFT 7 10 Code 93 Off C93ENA0 7 10 On C93ENA1 7 10 Code 93 Message Length Minimum 0 80 0 C93MIN 7 10 Maximum 0 80 80 C93MAX 7 10 Straight 2 of 5 Indus trial Default All Straight 2 of 5 Settings R25DFT 7 11 Straight 2 of 5 Indus trial Off R25ENA0 7 11 On R25ENA1 7 11 Stra...

Page 125: ...3 On C11ENA1 7 13 Code 11 Check Digits Required 1 Check Digit C11CK20 7 13 2 Check Digits C11CK21 7 13 Code 11 Message Length Minimum 1 80 4 C11MIN 7 14 Maximum 1 80 80 C11MAX 7 14 Code 128 Default All Code 128 Settings 128DFT 7 14 Code 128 Off 128ENA0 7 14 On 128ENA1 7 14 ISBT Concatenation On ISBENA1 7 14 Off ISBENA0 7 14 Code 128 Message Length Minimum 0 80 0 128MIN 7 15 Maximum 0 80 80 128MAX ...

Page 126: ...n UPAENA1 7 17 UPC A Check Digit Off UPACKX0 7 17 On UPACKX1 7 17 UPC A Number Sys tem Off UPANSX0 7 17 On UPANSX1 7 17 UPC A 2 Digit Addenda Off UPAAD20 7 18 On UPAAD21 7 18 UPC A 5 Digit Addenda Off UPAAD50 7 18 On UPAAD51 7 18 UPC A Addenda Required Not Required UPAARQ0 7 18 Required UPAARQ1 7 18 UPC A Addenda Separator Off UPAADS0 7 18 On UPAADS1 7 18 UPC E Default All UPC E Settings UPEDFT 7 ...

Page 127: ...a Separator Off UPEADS0 7 20 On UPEADS1 7 20 EAN JAN 13 Default All EAN JAN 13 Settings E13DFT 7 22 EAN JAN 13 Off E13ENA0 7 22 On E13ENA1 7 22 EAN JAN 13 Check Digit Off E13CKX0 7 22 On E13CKX1 7 22 EAN JAN 13 2 Digit Addenda Off E13AD20 7 22 On E13AD21 7 22 EAN JAN 13 5 Digit Addenda Off E13AD50 7 22 On E13AD51 7 22 EAN JAN 13 Addenda Required Not Required E13ARQ0 7 22 Required E13ARQ1 7 22 EAN ...

Page 128: ...arator Off EA8ADS0 7 25 On EA8ADS1 7 25 Coupon Code Off CPNENA0 7 25 On CPNENA1 7 19 MSI Default All MSI Settings MSIDFT 7 25 MSI Off MSIENA0 7 25 On MSIENA1 7 25 MSI Check Character Validate Type 10 but Don t Transmit MSICHK0 7 25 Validate Type 10 and Transmit MSICHK1 7 25 MSI Message Length Minimum 4 48 4 MSIMIN 7 26 Maximum 4 48 48 MSIMAX 7 26 Plessey Code Default All Plessey Set tings PLSDFT 7...

Page 129: ... 28 On RSEENA1 7 28 GS1 DataBar Expanded Msg Length Minimum 4 74 4 RSEMIN 7 28 Maximum 4 74 74 RSEMAX 7 28 China Post Code Default All China Post Code Settings CPCDFT 7 28 China Post Code Off CPCENA0 7 28 On CPCENA1 7 28 China Post Code Msg Length Minimum 2 80 4 CPCMIN 7 28 Maximum 2 80 80 CPCMAX 7 28 Korea Post Code Default All Korea Post Code Settings KPCDFT 7 29 Korea Post Code Off KPCENA0 7 29...

Page 130: ...ttings CBFDFT 7 31 Codablock F Off CBFENA0 7 31 On CBFENA1 7 31 Codablock F Msg Length Minimum 1 2048 1 CBF MIN 7 31 Maximum 1 2048 2048 CBF MAX 7 31 Code 16K Default All Code 16K Set tings 16KDFT 7 31 Code 16K Off 16KENA0 7 32 On 16KENA1 7 32 Code 16K Minimum 0 160 1 16KMIN 7 32 Maximum 0 160 160 16KMAX 7 32 Code 49 Default All Code 49 Set tings C49DFT 7 32 Code 49 Off C49ENA0 7 33 On C49ENA1 7 3...

Page 131: ...oPDF417 On MPDENA1 7 34 Off MPDENA0 7 34 MicroPDF417 Msg Length Minimum 1 366 1 MPDMIN 7 34 Maximum 1 366 366 MPDMAX 7 34 GS1 Composite Codes On COMENA1 7 34 Off COMENA0 7 34 UPC EAN Version On COMUPC1 7 35 Off COMUPC0 7 35 GS1 Composite Codes Msg Length Minimum 1 2435 1 COMMIN 7 35 Maximum 1 2435 2435 COMMAX 7 35 GS1 Emulation GS1 Emulation EANEMU2 7 35 GS1 128 Emulation EANEMU1 7 35 GS1 Emulatio...

Page 132: ...11 20 3800g 3800gHD 3800gPDF User s Guide ...

Page 133: ...5 degrees Horizontal Velocity 20 inches 50 cm per second Scan Contrast 20 minimum Voltage Requirements 3800GX4E 4 5 5 5VDC at imager 3800GX5E 4 5 12VDC at imager Current Draw Max Scanning Standby Inrush 3800GX4E 3800GX5E 5Vdc 235mA 87mA 380mA 3800GX5E 12VDC 126mA 50mA N A Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storage 40 F to 140 F 40 C to 60 C Humidity 0 to 95 non condensing Mecha...

Page 134: ... degrees Pitch Angle 65 degrees Horizontal Velocity 10 inches 50 cm per second Scan Contrast 37 minimum Voltage Requirements 4 5 to 5 5 VDC at imager Current Draw Max Scanning Standby Inrush 3800gHDX4E 3800gPDFX4E 5VDC 450mA 87mA 450mA Temperature Ranges Operating 32 F to 122 F 0 C to 50 C Storage 40 F to 140 F 40 C to 60 C Humidity 0 to 95 non condensing Mechanical Drop Operational after 50 drops...

Page 135: ...le Pinouts Keyboard Wedge 10 Pin RJ41 Modular Plug connects to the imager handle 1 2 Cord shield 3 Tied to supply power 4 Supply ground 5 Terminal clock 6 Terminal data 7 Supply power input Refer to tables on page 12 1 8 Keyboard data 9 Keyboard clock 10 ...

Page 136: ...dular Plug connects to the imager handle 1 2 Cord shield 3 Prog 1 Tied to supply power for primary cable 4 Supply ground 5 Receive data Serial data to imager 6 Transmit data Serial data from imager 7 Supply power input Refer to tables on page 12 1 8 Request to send data 9 Clear to send data 10 ...

Page 137: ...g 3800gHD 3800gPDF User s Guide 12 5 Standard Cable Pinouts USB 10 Pin Modular Plug connects to the imager handle 1 2 Data 3 Tied to supply power 4 Supply ground 5 6 7 5 volt supply power input 8 9 10 Data ...

Page 138: ...12 6 3800g 3800gHD 3800gPDF User s Guide ...

Page 139: ... window with a soft cloth or lens tissue dampened with water or a mild soapy water solu tion If a soapy water solution is used rinse with a clean lens tissue dampened with water only The scanner s housing may also be cleaned the same way Inspecting Cords and Connectors Inspect the scanner s interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may ...

Page 140: ...canner s handle This is the cable release 4 Straighten one end of a paper clip 5 Insert the end of the paper clip into the small hole and press in This depresses the retention tab releasing the connector Pull the connector out while maintaining pressure on the paper clip then remove the paper clip 6 Replace with the new cable Insert the connector into the opening and press firmly The connector is ...

Page 141: ...nner reads a bar code but the data is not displayed correctly on the host screen The scanner may not be programmed for the appropriate terminal interface For example you scan 12345 and the host displays es Reprogram the scanner with the correct Plug and Play or Terminal selection bar code See Chapter 1 and Chapter 2 The scanner may not be programmed to output your bar code data properly For exampl...

Page 142: ...13 4 3800g 3800gHD 3800gPDF User s Guide ...

Page 143: ...razil Telephone 55 21 3535 9100 Fax 55 21 3535 9105 E mail brsuporte handheld com Mexico Telephone 803 835 8000 E mail latechsupport handheld com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail eurosupport handheld com Asia Pacific Telephone Hong Kong 852 3188 3485 or 2511 3050 Telephone China 86 21 6361 3818 E mail aptechsupport handheld com Japan Telephone 81...

Page 144: ...00 Telephone 800 782 4263 Fax 239 263 9689 E mail laservice handheld com Brazil Telephone 55 21 3535 9100 Fax 55 21 3535 9105 E mail brservice handheld com Mexico Telephone 52 55 5203 2100 Fax 52 55 5531 3672 E mail mxservice handheld com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euservice handheld com Asia Pacific Telephone 852 2511 3050 Fax 852 2511 355...

Page 145: ...t a Return Materials Authoriza tion which may be obtained by contacting Honeywell In the event that the product is returned to Honeywell or its authorized service center within the War ranty Period and Honeywell determines to its satisfaction that the product is defective due to defects in materials or workmanship Honeywell at its sole option will either repair or replace the product without charg...

Page 146: ...ceable such determina tion shall not affect the validity of enforceability of the other provisions hereof Use of any peripherals not manufactured sold by Honeywell may result in dam age not covered by this warranty This includes but is not limited to cables power supplies cradles and docking stations Honeywell extends these war ranties only to users of the products These warranties are non transfe...

Page 147: ...logy Code ID AIM ID Hex ID China Post Q X0 51 GS1 DataBar GS1 DataBar Ominidi rectional GS1 DataBar Limited GS1 DataBar Expanded y em 79 Codabar a Fm 61 IATA 2 of 5 f Rm 66 Codablock F q Om 71 Interleaved 2 of 5 e lm 65 Code 2 of 5 f Rm 66 Korea Post X0 3F Code 11 h Hm 68 Matrix 2 of 5 m X0 6D Code 16K o Km 6F MSI g Mm 67 Code 39 b Am 62 No Read 9C Code 32 Pharma ceutical PARAF X0 3C Plessey Code ...

Page 148: ... HT 41 29 73 49 l 105 69 i 10 0A LF 42 2A 74 4A J 106 6A j 11 0B VT 43 2B 75 4B K 107 6B k 12 0C FF 44 2C 76 4C L 108 6C l 13 0D CR 45 2D 77 4D M 109 6D m 14 0E SO 46 2E 78 4E N 110 6E n 15 0F SI 47 2F 79 4F O 111 6F o 16 10 DLE 48 30 0 80 50 P 112 70 p 17 11 DC1 49 31 1 81 51 Q 113 71 q 18 12 DC2 50 32 2 82 52 R 114 72 r 19 13 DC3 51 33 3 83 53 S 115 73 s 20 14 DC4 52 34 4 84 54 T 116 74 t 21 15 ...

Page 149: ...3 CB Ë 235 EB ë 140 8C Œ 172 AC 204 CC Ì 236 EC ì 141 8D 173 AD 205 CD Í 237 ED í 142 8E Ž 174 AE 206 CE Î 238 EE î 143 8F 175 AF 207 CF Ï 239 EF ï 144 90 176 B0 208 D0 Ð 240 F0 ð 145 91 177 B1 209 D1 Ñ 241 F1 ñ 146 92 178 B2 210 D2 Ò 242 F2 ò 147 93 179 B3 211 D3 Ó 243 F3 ó 148 94 180 B4 212 D4 Ô 244 F4 ô 149 95 181 B5 µ 213 D5 Õ 245 F5 õ 150 96 182 B6 214 D6 Ö 246 F6 ö 151 97 183 B7 215 D7 247 F...

Page 150: ...Page option is available for Code 39 Code 93 and Code 128 Code Page Standard Description 1 CP ISO646 2 Default ISO 2022 Automatic National Replacement Characters 3 CP Binary 82 ISO 2022 11 Swe Swedish Replacement Characters 83 ISO 2022 69 Fra French Belgium Replacement Charac ters 81 ISO 2022 25 Fra French Belgium Replacement Charac ters 84 ISO 2022 11 Ger German Replacement Characters 85 ISO 2022...

Page 151: ...3800g 3800gHD 3800gPDF User s Guide Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 1234567890 Code 128 9 780330 290951 654 EAN 8 3210 5 456123 8 0 UPC E ...

Page 152: ...00gPDF User s Guide Sample Symbols Code 93 123456 9 Straight 2 of 5 Industrial 123456 Matrix 2 of 5 6543210 GS1 DataBar 01 00123456789012 Code 39 Codabar BC321 A13579B Micro PDF417 Test Message PDF417 Car Registration ...

Page 153: ...3800g 3800gHD 3800gPDF User s Guide ...

Page 154: ...3800g 3800gHD 3800gPDF User s Guide ...

Page 155: ...rogramming Chart A C Save B Discard F E D Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save 0 2 6 1 7 5 4 3 8 9 ...

Page 156: ...Honeywell 700 Visions Drive P O Box 208 Skaneateles Falls NY 13153 0208 3800g UG Rev B 6 08 ...