16
69-0643—1
Troubleshooting (Continued)
Problem
Check
Action
Room
— Thermostat circuits.
Heating mode—Move temperature
temperatures
setting levers 5
°
F [3
°
C] above room
are not correct
temperature. Heating system should
(continued).
start.
Cooling mode—Move temperature
setting levers 5
°
F [3
°
C] below room
temperature. Cooling system should
start. If the system does not operate,
call a qualified service technician.
Burner-on time
— Anticipator setting. (See Fig. 6
Increase anticipator setting by 0.05
too short.
for anticipator location.)
(e.g., 0.4 to 0.45). Observe burner
operation.
Burner-on time too
— Anticipator setting. (See Fig. 6
Decrease anticipator setting by 0.05
long.
for anticipator location.)
(e.g., 0.45 to 0.4). Observe burner
operation.
(continued)