Technical data
Rated operating voltage
12 V DC
Operating voltage range
9 V to 15 V DC
<11 mA
<50 mA (in l.
(Time lag after last transponder reactivation 5 sec.)
Luminous background
Connectable
-
Brightness (settable)
<4 mA (time-limited for 5 sec. max. 8 mA)
Mounting surface
Any surface, also metal
Transmission range
Settable
The transmission range depends on the mounting surface and the transponder that is being
used. The following information refers to the range when using an ID card.
-
Non-metallic mounting surface
Approx. max. 80 mm with ID card
-
Steel mounting surface
Approx. max. 60 mm with ID card
-
Aluminium as mounting surface
Approx. max. 70 mm with ID card
Interface
RS-485 and Clock/Data
Housing dimensions (W x H x D)
75 x 142 x 32 mm
Colour
White aluminium (similar to RAL 9006)
Current consumption in stand by mode
(on average)
Time-limited read mode
c status indication)
(026421.10)
Wiegand (026421.20)
Connecting cable
12-core, shielded, 6 m
Frequency range, transmission power
125 kHz, <10 dBµA/m
Protection category as per EN 60529
IP 65
Environmental class as per VdS
III
Operating temperature range
-25 °C to +55 °C
9.
Accessories
023314
023315
023316.99
023501
023329
Front white aluminium (similar to RAL 9006)
PU = 3 pce.
Front pure white (similar to RAL 9010)
PU = 3 pce.
Front anthracite (
)
PU = 3 pce.
Plastic shield weather/view
Mounting plate
PU = 3 pce.
satin grey metallic
ID carrier
Apart from Legic and mifare, all contactless Novar information carriers can be used as ID carriers.
Please refer to the current product catalogue.
Mounting and Operating Instructions - proX2-reader "Accentic" with keypad
Hereby, the Novar GmbH declares that the radio equipment proX2-reader "Accentic" with
keypad Item no. 026421.10 and 026421.20 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration can be downloaded from our homepage
https://www.security.honeywell.de/ in the service/download area.