background image

Mounting Instructions

Case back flush mount

Item no. 013046

(white)
(gray)

Item no. 013047

(black)

Item no. 013048

suitable for:

- LED Keypad for MB-Secure
- LED/LCD Keypad for MB-Secure
- Touch operating module

TouchCenter plus

- FM Frame for TC plus, Item no. 013051

Mounting

Wall recess:

Prepare a wall recess with dimensions 208 x 152 mm.
Total depth at least 30 mm.
Ensure that the recess is no larger than the external
dimensions of the edge (218 x 162 mm).

Preparation for a

:

TouchCenter plus

-

4

Disengage the

retaining connectors.

- Remove cover contact actuation/tear-off protection for

LED and LED/LCD Keypad 3.

- Completely screw in

6 (Accessory

adjusting screw

TouchCenter plus)

an

.

with

appropriate tool

- Now unscrew adjusting screw till the cover contact is

audibly actuated when the TouchCenter plus is inserted into
the case back.

Array flush-mounted case backs:

Flush-mounted case backs that have been arrayed
(horizontally and/or vertically) must be mounted with
correct spacing.
- Insert connection elements in the mounting system

from rear to front, as shown in the diagram.

- Screw in and tighten moderately.

Captions:

1 Mounting system to fix claw fasteners or

connection elements (see below)

2 Cable inlets
3 Cover contact actuation for LED and LED/LCD

Keypad

4 Retaining connectors
5

TouchCenter plus

Cover contact actuation for

6 Adjusting screw for cover contact actuation

(Accessory TouchCenter plus)

7 Pull relief holder for cable ties

Claw fasteners for installation in cavity walls:

- Position claw fasteners as shown in diagram.

- Screw in till claw fasteners are firmly in place.

- Place housing in the cavity wall.

- Tighten screws. The claw fasteners rotate by 90°.

- Tighten screws till the housing is securely fastened.

1

3

4

7

1

1

7

1

5

1

6

1

1

1

218
208

152

162

152

162

30

1

To bring out the cable inlets, place the screw diver in
the center and pivot them out.

2

Summary of Contents for 013046

Page 1: ...estigt ist uP Einbaudose Art Nr 013046 weiß grau Art Nr 013047 schwarz Art Nr 013048 Montageanleitung P00468 47 002 02 HSG 2018 07 18 Änderungen vorbehalten passend zu LED Bedienteile für MB Secure LED LCD Bedienteile für MB Secure Grafik Bedienteil TouchCenter plus uP Blendrahmen Art Nr 013051 Einbaudosen aneinander reihen Aneinander gereihte Einbaudosen horizontal und oder vertikal müssen in ein...

Page 2: ...y flush mounted case backs Flush mounted case backs that have been arrayed horizontally and or vertically must be mounted with correct spacing Insert connection elements in the mounting system from rear to front as shown in the diagram Screw in and tighten moderately Captions 1 Mounting system to fix claw fasteners or connection elements see below 2 Cable inlets 3 Cover contact actuation for LED a...

Page 3: ...inander ziehen und seitlich einrasten und letztlich die oberen Rastnasen hinten einrasten 5 Bei Bedarf z B bei Wand Unebenheiten oder unzureichender Klemm Festigkeit kann der Rahmen auch individuell auf der Wand mittels mehrerer Klebepunkte z B Silikon befestigt werden Montage Um den uP Blendrahmen auf dasTouchCenter plus oder einem MB Secure Bedienteil korrekt aufklemmen zu kön nen muss die uP Ei...

Page 4: ...des finally locking the upper locking lugs over the inserted TC plus or keypad and engage in the back 5 If necessary e g in the case of wall unevenness or inadequate clamping strength the frame can also be moun ted individually on the wall by means of several adhesive dots e g Silicone Mounting In order to be able to clamp the FM Frame on the Touch Center plus or on a MB Secure kepad correctly the...

Reviews: