6
Typical wiring of a conventional system with up to 3-stage heat and 2-stage cool
with one transformer. (RedLINK FocusPRO up to two-stage heat and two-stage
cool.)
NOTE:
See following pages for additional thermostat wiring guidelines for
heat pumps, geothermal systems and optional Economizer.
See guides on following pages for thermostat wiring and geothermal radiant
heat wiring.
Wire a maximum of 4 sensors using the S1-S4 terminals. S1-S4 terminals can
be connected to an indoor sensor, outdoor sensor, discharge sensor, return
sensor, dry contact device to display an alert or an occupancy sensor for
remote setback. RedLINK FocusPRO should only use the return sensor to any
of the four sets of S terminals.
Remove jumper(s) if using separate transformers.
See Economizer wiring section.
HEAT STAGE 1
HEAT STAGE 2
HEAT STAGE 3
FAN
TO THERMOSTAT
STATUS
LEDS
JUMPERS
SENSORS
CONV
FURNACE
R
C
W
W2
W3
G
Y2
Y
TRANSFORMER
120
VAC
24
VAC
COMPRESSOR
STAGE 1
COMPRESSOR
STAGE 2
POWER
HEAT
COOL
FAN
U1
U2
U3
A
CONNECT OPTIONAL
SENSORS TO
S1 AND S2 TERMINALS
S4
S4
S3
S3
CONNECT OPTIONAL
SENSORS TO
S3 AND S4 TERMINALS
A
B
C
D
EIM
M34249
2
3
1
4
2
5
EIM wiring guide — conventional systems
1
2
3
4
Connect wireless adapter to ABCD for extended wireless range.
5