background image

 

16 

 

1

 

When menu is not opened, contrast adjust 
message is shown by pressing right key. Each 
when right key is pressed, numbers of contrast 
increases up to +4. 

2

 

When menu is not opened, contrast adjust 
message is shown by pressing left key. Each 
when left key is pressed, numbers of contrast 

decreases up to -4.   

3

 

Adjust contrast with left or right key so that 
flicker could not be remarkable. 

5.    TO SET CLUTTER 
CLUTTER 
Fish school or bottom is displayed while the strength of reflected echo is   
corresponded with pre-set color configuration. 
As this can delete colors in turn from color of weakest echo, it will be enable 
to distinguish this school easily be deleting the weak echoes like plankton, stain 
in the water or etc. 
 

Set CLUTTER on menu 1. 

  Each  time  when  CLUTTER 

  key  is  pressed,  color  from  the  strongest 

reflected echo disappears in turn. 

  Each  time  when  CLUTTER 

  key  is  pressed,  color  from  the  strongest 

reflected echo restores in turn. 

             

 

 

Right key 

Left Key 

CLUTTER 

  key 

CLUTTER 

  key 

CLUTTER 

  key

 

CLUTTER 

  key

 

<Portrait> 

<Landscape> 

<Portrait Reverse> 

<Landscape Reverse> 

Summary of Contents for HE-1500

Page 1: ......

Page 2: ...which is not described on this manual or wrong operation DEFINITION OF SYMBOL MARK CAUTION FOR SAFETY incur the accident resulting in the death or serious wound unless you keep the descriptions Be in...

Page 3: ...9 TO CONTROL BRIGHTNESS OF SCREEN 10 HOW TO SEE THE DISPLAY 11 OPERATION ON FRONT PANEL 12 1 TO SET THE DEPTH DISPLAY RANGE 12 2 TO SET SHIFT DISPLAY RANGE SHIFT 13 3 TO ADJUST SENSITIVITY 13 4 TO ADJ...

Page 4: ...5 TO CHANGE DISPLAY STYLE PORTRAIT LANDSCAPE 26 26 INITIALIZATION 26 MENU CONTENTS AND FACTORY SETTING 27 DIMENSIONAL DRAWING 28 1 DIMENSIONAL DRAWING OF MAIN UNIT 28 2 DRAWING OF HOLES FOR INSTALLING...

Page 5: ...ill occur Please be sure to consult with dealer when you want to repair Do not install it in simple method It causes to the accident like human damage Please be sure to install correctly according to...

Page 6: ...excessively Do not disassemble or modify the cables It causes to heating firing or electric shock Do not use the damaged cables It causes to firing or electric shock Do not pull the cable when you pu...

Page 7: ...ur hands dry If you hands are wet it causes to electric shock When you pull out or insert the plug of transducer or water temperature sensor please be sure to turn the power switch off It causes to el...

Page 8: ...s possible 4 Prohibited to use the organic solution Do not clean the unit with organic solution like thinner alcohol or etc as some parts of the unit and panel are coated or made by plastic In case it...

Page 9: ...ZOOM page 17 Move the expanded area toward sea surface or sea bottom When manual expansion is selected CLUTTER page 16 Set the clutter MENU page 8 Show Menu mode SET page 8 It is used when you execut...

Page 10: ...el menu MODE page 17 Switch Normal mode Bottom Lock mode Auto Expansion or Manual Expansion Power Lamp page 9 It lights on when the power switch is ON POWER BRIGHTNES page 10 It turns Power ON OFF and...

Page 11: ...W OF MAIN UNIT DESCRIPTIONS Power supply of monitor 5P Option RGB image output Option External input output 6P Water temp sensor 8P DC power supply 2P Transducer 3P or 5P 5P for 50 200kHz HE 1500 HE 7...

Page 12: ...CTION Up Down key Blue selected item moves upward pressing Up key When Up key is pressed while selected item is located on the top item blue selected item moves to bottom Blue selected item moves down...

Page 13: ...shown after power turns ON OFF key is not activated Note When the engine starts to run battery voltage varies and it may affect to main unit Start the engine after the power of main unit is turned OF...

Page 14: ...Control of brightness Adjust the brightness of screen Turning the brightness knob clockwisely the display becomes bright Turning the brightness knob counterclock wisely the display becomes dark OFF Po...

Page 15: ...In case main unit is single frequency No indication In case main unit is dual frequencies L Low Frequency H High Frequency However in case of dual frequency parallel display position of readout moves...

Page 16: ...is displayed Depth range you can set differs depending on frequency 1 To decrease the depth display range Each time when you press RANGE key the depth decreases 2 To increase the depth display range...

Page 17: ...To shift to shallow depth Each time when you press SHIFT key the display range becomes shallow 2 To shift to deep depth Each time when you press SHIFT key the display range becomes deep 3 TO ADJUST S...

Page 18: ...tom again The next reflection from bottom is called the second reflection Normally it s second reflection is shown on the twice depth of the actual bottom first reflection 1 To decrease sensitivity Ea...

Page 19: ...sensitivity increases 2 Adjust sensitivity of right display with GAIN 1 key To decrease sensitivity Each time when you press GAIN 1 key gain bar becomes short and the sensitivity decreases To increase...

Page 20: ...bottom is displayed while the strength of reflected echo is corresponded with pre set color configuration As this can delete colors in turn from color of weakest echo it will be enable to distinguish...

Page 21: ...r of bottom MANUAL EXPANSION Expanded display up or down in the center of optional position You can mode expanded area by ZOOM key as you wish Displayed range varies depending on Expansion Rate Refer...

Page 22: ...ves upward pressing Up key Depth at the position of marker is indicated with number above marker SETTING ON MENU 1 TO SET SWEEPING SPEED Sweeping Speed Sweeping Speed On echo sounder fish finder the n...

Page 23: ...creen between fish finder display and depth calibration and it s width changes according to strength of reflected signal Strong response is indicated thick and weak signal is indicated thin ON A MODE...

Page 24: ...from sea bottom is even Set AUTO GAIN on Menu 1 LOW Sensitivity decreases When you judge status of bottom it helps you to confirm second or third reflection HIGH Sensitivity increases It helps you to...

Page 25: ...ak response near sea surface becomes strong and you can not judge the image in some case Set STC on menu 1 WEAK MEDIUM STRONG OFF Canceled 10 TO SET BACKGROUND COLOR Background Color Reflected echo is...

Page 26: ...ay defined color specially Set COLOR CONFIG on MENU 2 7 patterns 0 6 13 TO SET WATER TEMP GRAPH Water Temp Graph Water temperature graph is shown on the screen It enables you to know the variation of...

Page 27: ...hin two water temperatures OUT RANGE Alarm goes off when it is out of two water temperatures OFF Water temp alarm is canceled 3 Set TEMP SET1 and TEMP SET2 16 TO SET DEPTH ALARM Depth Alarm Alarm goes...

Page 28: ...to set displayed depth range When LONG is selected twice pulse length of NORM setting can be set The shorter pulse length sensitivity decreases The longer pulse length sensitivity increases Set PULSE...

Page 29: ...readout always differs from actual water temp at constant value it corrects error of water temp Set ADJUST on menu 3 1 TEMP CORRECT is shown by pressing right key Value of correction is increased by...

Page 30: ...mode Select OFF to return the normal display 25 TO CHANGE DISPLAY STYLE PORTRAIT LANDSCAPE Change of display style Portrait Landscape You can change the display landscape portrait landscape reverse a...

Page 31: ...27 MENU CONTENTS AND FACTORY SETTING...

Page 32: ...28 DIMENSIONAL DRAWING 1 DIMENSIONAL DRAWING OF MAIN UNIT HE 7300II HE 775 2 DRAWING OF HOLES FOR INSTALLING BRACKET UNIT mm...

Page 33: ...29 1 DIMENSIONAL DRAWING OF MAIN UNIT HE 1500 2 DRAWING OF HOLES FOR INSTALLING BRACKET UNIT mm...

Page 34: ...30 CONNECTION WITH MAIN UNIT...

Page 35: ...E 775 Procedure of installing main unit 1 Decision of place you install While the bracket is mounted with unit you decide the place you install and put the mark Keep enough space behind the unit to co...

Page 36: ...l the bracket with supplied screws into eight outside holes 3 Installation of unit Install the unit referring to the below figure 1 Fix the Fitting Metal by Hexagon bolt to the unit then screw the Cla...

Page 37: ...nel with screws through four holes of unit as below HE 7300II HE 775 1 Please make hole on the panel referring to below dimensional drawing Do not install in a simple method It causes to accident like...

Page 38: ...34 HE 1500 1 Please make hole on the panel referring to below dimensional drawings...

Page 39: ...ake off four lids put on holes 3 Pull them toward front side Then lids are removed 5 Fix the unit with tapping screws 6 Put four lids onto the unit again M4x30 4 Put main unit into hole drilled on the...

Page 40: ...ufficient it causes to marine disaster because water comes in When you work using electric tools please keep your hands dry If you hands are wet it causes to electric shock Do not install on the alumi...

Page 41: ...e sensor should be done after you land and fix the boat Unless you keep it human damage resulting in death or serious wound will occur When you work using electric tools please keep your hands dry It...

Page 42: ...E 7300II HE 775 Screw for installing bracket M6x20 SUS x 4 pcs Pan head tapping screw for installing into dash board M4x30 SUS x 4 pcs Power Supply Cable DC07 2P 2m Cable Cover withM4x16 SUS Pan head...

Page 43: ...Temp Sensor EK11 8P 8P 3m Transom Water Temp Sensor TC02ES TCT01 8P 15m Extension cable for Monitor Power Supply 5P 5P 3m RGB Cable 10m RGB Extension Cable 3m 15 LCD Monitor 10 4 LCD Monitor RGB Cabl...

Page 44: ...40...

Page 45: ...41...

Page 46: ...42...

Page 47: ...43...

Page 48: ...Fish Alarm OFF Small Large Water Temp Alarm OFF Within Range Out of Range Depth Alarm OFF Within Range Out of Range Expansion Mode OFF Bottom Lock Auto Exp Manual Exp Expansion Rate x2 x4 x8 Sweep Spe...

Page 49: ......

Reviews: