8-6
FLYWHEEL/IGNITION COIL/ STARTER MOTOR
GX120K1•GX160K1•GX200
BRUSH LENGTH
Measure the brush length.
If brush length is less than service limit, replace the brush and
brush holder plate.
ARMATURE
• Continuity check-commutator segments
Check for continuity between the segments. If an open circuit (no
continuity) exists between any two segments, replace the
armature.
•
Continuity check-commutator-to-shaft
Check continuity between the commutator and the armature shaft.
Replace the armature if continuity exists between any of the
commutator segments and the armature shaft.
•
Mica depth
When the mica is clogged, or its depth is smaller than the service
limit value, recut the grooves using a hacksaw blade or a small
file.
Standard
Service limit
11.0 mm (0. 43 in)
6.0 mm (0.24 in)
Standard
Service limit
1.6 mm (0.06 in)
1.1 mm (0.04 in)
gx120k1_gx160k1_gx200
Summary of Contents for GX120K1
Page 14: ...1 9 GX120K1 GX160K1 GX200 SPECIFICATIONS GX160K1 GX160U1 GX160UT1 gx120k1_gx160k1_gx200 ...
Page 15: ...1 10 SPECIFICATIONS GX120K1 GX160K1 GX200 GX200 GX200U GX200UT gx120k1_gx160k1_gx200 ...
Page 19: ...1 14 SPECIFICATIONS GX120K1 GX160K1 GX200 GX160K1 Unit mm in gx120k1_gx160k1_gx200 ...
Page 67: ...4 4 AIR CLEANER MUFFLER GX120K1 GX160K1 GX200 Rammer type P 3 6 P 3 6 gx120k1_gx160k1_gx200 ...
Page 69: ...4 6 AIR CLEANER MUFFLER GX120K1 GX160K1 GX200 Rammer type gx120k1_gx160k1_gx200 ...
Page 71: ...5 2 RECOIL STARTER FAN COVER GX120K1 GX160K1 GX200 GX200 gx120k1_gx160k1_gx200 ...
Page 80: ...6 1 6 CARBURETOR 1 CARBURETOR 6 2 gx120k1_gx160k1_gx200 ...
Page 81: ...6 2 CARBURETOR GX120K1 GX160K1 GX200 1 CARBURETOR REMOVAL INSTALLATION gx120k1_gx160k1_gx200 ...
Page 82: ...6 3 GX120K1 GX160K1 GX200 CARBURETOR Rammer type gx120k1_gx160k1_gx200 ...
Page 101: ...9 1 9 CYLINDER HEAD VALVES 1 CYLINDER HEAD VALVES 9 2 gx120k1_gx160k1_gx200 ...
Page 120: ...11 1 11 GOVERNOR OIL LEVEL SWITCH 1 GOVERNOR OIL LEVEL SWITCH 11 2 gx120k1_gx160k1_gx200 ...