SERVICING YOUR GENERATOR
67
ENGINE OIL CHANGE
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Place a suitable container below the engine to catch the used oil, and then
remove the oil filler cap/dipstick, 12×15 mm drain plug, and sealing washer.
2. Allow the used oil to drain completely, and then reinstall the 12×15 mm drain
plug and a new sealing washer. Tighten the plug securely.
Torque:
16.3 lbf·ft (22.1 N·m, 2.25 kgf·m)
3. With the generator in a level position, fill to the upper limit mark on the
dipstick with the recommended oil (see page 18).
Maximum oil capacity:
1.2 US qt (1.1 L)
4. Reinstall the oil filler cap/dipstick securely.
Wash your hands with soap and water after handling used oil.
Improper disposal of engine oil can be harmful to the environment. If you change
your own oil, please dispose of it properly. Put it in a sealed container, and take it to a
recycling center. Do not discard it in a trash bin, dump it on the ground, or pour it
down a drain.
SEALING
WASHER
(Replace)
12×15 mm
OIL DRAIN PLUG
OIL FILLER CAP/DIPSTICK
UPPER LIMIT
LOWER LIMIT
31Z238200.book 67 ページ 2020年2月20日 木曜日 午前10時57分