 Lutron

®

24/7 Technical Support—800.523.9466

product specifications

01.24.13

369755a

HomeWorks

®

 QS MDU Processor

Specifications

Model Numbers

HQP6-MDU

Power

Processor  (P): 24 V

-

  250 mA

Links (L1 / L2): 24 V

-

  2 A per link

Typical Power 

Consumption

5 W; 8 Power Draw Units (PDUs) 

Test conditions: Two Ethernet links connected, both device links in use

Regulatory Approvals

UL, cUL, CE, CTICK

Environment

Indoor use only.  32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity,  

non-condensing

Heat Generated

17 BTU/hr — typical 

(24 BTU/hr with 2 links at 2 A each output)

Cooling Method

Passive Cooling

Power Failure Memory

System data stored in non-volatile memory. Timeclock retention for 10 years

Internal Timeclock

±1 minute per year

Miswire Protection

All terminal block inputs are over-voltage and miswire protected against wire 

reversals and shorts.

Low-Voltage Link  

Wire Type

Two pair — one pair 18 AWG (0.75 mm

2

), one pair 18 to 22 AWG  

(0.34 to 0.75 mm

2

) twisted shielded — IEC PELV / NEC

®

 Class 2 cable

Low-Voltage Power 

Wire Type

18 AWG (0.75 mm

2

)

Communications

Ethernet, RS485 (QS, RF, Power Panel)

Link Capacities

Total link capacity between the HomeWorks

®

 QS Wired Device Link and the 

HomeWorks

®

 QS RF Link cannot exceed 50 devices / 50 zones.

ESD Protection

Meets or exceeds the IEC 61000-4-2 standard

Surge Protection

Meets or exceeds ANSI/IEEE C62.41 standard

Mounting

Mounts in HQ-LV21, L-LV14, or L-LV21

Dimensions

With terminal blocks (as shown): 4.27 in (108 mm) x 6.0 in (152 mm)

Without terminal blocks: 4.27 in (108 mm) x 5.26 in (134 mm)

Connections

Two 5-pin removable terminal blocks* for Links 1 and 2.

One 5-pin removable terminal block* for Power Input.

Two RJ 45 standard Ethernet connections.

* Each terminal will accept up to two 18 AWG (0.75 mm

2

) wires. 

Warranty

http://www.lutron.com/TechnicalDocumentLibrary/HomeWorks_Warranty.pdf 
http://www.lutron.com/TechnicalDocumentLibrary/  HomeWorks_Intl_Warranty.pdf  

NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts.

Summary of Contents for QS HQP6-MDU

Page 1: ...e device application The processor is typically powered from the QSPS DH 1 60 power supply The HomeWorks QS MDU processor can be installed in a HQ LV21 L LV21 or L LV14 enclosure Processor Capabilities The HomeWorks QS MDU processor has 2 links that are preconfigured as HomeWorks QS Wired Link and HomeWorks QS RF Link The processor has a capacity of 50 devices 50 zones maxiumum shared between the ...

Page 2: ... mm2 one pair 18 to 22 AWG 0 34 to 0 75 mm2 twisted shielded IEC PELV NEC Class 2 cable Low Voltage Power Wire Type 18 AWG 0 75 mm2 Communications Ethernet RS485 QS RF Power Panel Link Capacities Total link capacity between the HomeWorks QS Wired Device Link and the HomeWorks QS RF Link cannot exceed 50 devices 50 zones ESD Protection Meets or exceeds the IEC 61000 4 2 standard Surge Protection Me...

Page 3: ...Lutron 3 www lutron com product specifications 01 24 13 369755a HomeWorks QS MDU Processor Dimensions Dimensions shown as in mm Front View Side View 1 06 26 9 6 0 125 5 26 134 4 27 108 ...

Page 4: ...roduct specifications 01 24 13 369755a HomeWorks QS MDU Processor Wire Landing Boards QS WLB Example Mounting L LV14 5 Ground 4 Red L2 Link 2 Power 3 Red L1 Link 1 Power 2 Red P Processor Power 1 Black COM Common DIN Rail Power Supply QSPS DH 1 60 ...

Page 5: ...ximum each run Ad hoc Networking Direct Ethernet connection from PC to MDU processor Standard Networking Connection using an Ethernet hub switch router WAN LAN Laptop PC Ethernet Router HomeWorksR QS MDU processor HomeWorksR QS MDU processor Ethernet cable Cat5 Cat5e 328 ft 100 m maximum per home run 328 ft 100 m max 3rd Party Integration Device not supplied by Lutron ...

Page 6: ...da Sortie 22 5 25 V Max 2A combined Draw from processor when powering both links from the same power supply 5 Ground 3 Red L1 Link 1 Power 2 Red P Processor Power 1 Black COM Common 1 Black COM Common 4 Red L2 Link 2 Power up to 50 device addresses up to 50 device addresses RF Link QS Link Total link capacity between the HomeWorks QS Wired Device Link and the HomeWorks QS RF Link cannot exceed 50 ...

Page 7: ...M 24 V 9 V 1 MUX MUX 2 3 4 Activate Test Hybrid Repeater Add Test Setup Wired RF Communication Repeater Status 1 3 4 2 P Hybrid Repeater Power Repeater Link COM 24 V 9 V 1 MUX MUX 2 3 4 Activate Test Add Test Setup Wired RF Communication Repeater Status 1 3 4 2 P Hybrid Repeater Power Repeater Link COM 24 V 9 V 1 MUX MUX 2 3 4 Activate Test HomeworksR QS Processor HQP6 MDU HomeworksR QS RF Link 10...

Page 8: ...U Processor Wiring Diagrams HomeWorks QS Wired QS Link with Shades Draperies Controllable Window Solutions L N QSPS DH 1 60 120 240 V Input Entrada Entrée 24 V Output Salida Sortie 22 5 25 V HomeworksR QS wired devices HomeworksR QS wired devices QS Link 120 V 60 Hz QSPS P1 10 60 QS Smart Power Panel ...

Reviews: