SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the product.
• 

Always disconnect the power supply prior to servicing the fan, 

motor or junction box.

• 

Follow all local building, safety and electrical codes as well 

as NEC (National Electrical Code) and OSHA (Occupational 

Safety and Health Act).

• 

Electric Service supply must be 120 volts, 60 hertz.

• 

This product must properly connect to the grounding 

conductor of the supply circuit.

• 

Do not bend or kink the power wires.

• 

Do not install in a ceiling with insulation greater than R40.

• 

Duct work should be installed in a straight line with minimal 

bends.

• 

Duct work size must be the same size as the discharge and 

should not be reduced. Reducing the duct size may increase 

fan noise.

• 

This product is not intended for connection to rigid metal 

conduit. For use with flexible conduit only.

WARNING: To reduce the risk of fire, electric shock, 

or injury to persons, observe the following:

1.  Use this unit in the manner intended by the manufacturer.  

If you have any questions, please call customer service.

2.  Before servicing or, cleaning the unit, switch the power off at 

the service panel and lock the service disconnecting means to 

prevent the power from being switched on accidentally. 

When the service disconnecting means cannot be locked, 

securely fasten a prominent warning device, such as a tag, 

to the service panel. 

3.  Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction. 

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting.Follow the heating equipment 

manufacturer´s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE) and local code authorities.

5.  When cutting or drilling into the wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  To reduce risk of fire and to properly exhaust air, be sure to 

vent air to the outdoors. Do not vent exhaust air into spaces 

within walls or ceilings, or into attics, crawl spaces, or garages. 

7.  If this unit is to be installed over a tub or shower, it must be 

marked as appropriate for the application and be connected 

to a GFCI (Ground Fault Circuit Interruptor)-protected branch 

circuit.

8.  This ventilation fan is intended to be installed at least  

3 ft. 3-1/4 in. (1 m) from the showerhead when installing over  

a bathtub or shower. Installation within a shower stall is not 

recommended for this unit, unless the 3 ft. 3-1/4 in. (1 m) 

distance can be met.

CAUTION 

•  For general ventilating use only. Do not use to 

exhaust hazardous or explosive materials and 

vapors.

•  Not for use in kitchens.

•  To reduce the risk of injury to persons, install the 

fan at least 7 feet (2.1m) above the floor.

•  To reduce risk of fire and to properly exhaust air, 

be sure to vent air to the outdoors. Do not vent 

exhaust air into spaces within walls or ceilings, 

or into attics, crawl spaces, or garages.

CAUTION:

 Installation of this unit requires the power to be OFF until installation is complete. If you encounter issues with the unit not 

powering up, please review the troubleshooting section of the instruction manual.
If you require additional assistance, please call 1-877-319-3757, 7:30 a.m. - 4:30 p.m., CST, Monday - Friday. 

DO NOT RETURN TO STORE.

 

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents 

list and hardware contents. If any part is missing or damaged, do not attempt to assemble, install or operate 

the product. Contact customer service for replacement parts at 1-877-319-3757, 7:30 a.m. - 4:30 p.m., CST, 

Monday - Friday. 

Estimated Assembly Time: 60 minutes

Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wood Screws, Duct Tape, Phillips 

Screwdriver, and Utility Knife or Drywall Saw 
Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: RISK OF ELECTRIC SHOCK! Ensure the electricity to the wires you are working on is shut off. 

Either remove the fuse or turn off the circuit breaker before removing the existing bath fan or installing 

the new one.

 Before removing your current ventilation fan, verify the wall switch box has the required wires 

necessary for this installation. These supply wires are power (black) and neutral (white), as shown  

in the wiring diagram below. If you do not see both of these wires, consult a licensed electrician.

Summary of Contents for 7141-80-G3

Page 1: ...service department at 1 877 319 3757 7 30 a m 4 30 p m CST Monday Friday VENTILATION FAN WITH LIGHT MODEL 7141 80 G3 Espa ol p 13 READ AND SAVE THESE INSTRUCTIONS 05 2021 ATTACH YOUR RECEIPT HERE Ser...

Page 2: ...Watts 120 V 60 Hz LED life 30 000 hours Duct diameter 4 in LED light brightness 1000 lumens dimmable Motor power consumption 28W Product Specifications 2 Package Contents 2 Hardware Included 2 Safety...

Page 3: ...s Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages 7 If this unit is to be installed over a tub or shower it must be marked as appropriate for the ap...

Page 4: ...Accessory part quick connector should meet installation instructions below Quick connect House wires Product wires NOTE The connector is reusable on solid wires of the same wire gauge or smaller Do no...

Page 5: ...housing A next to a ceiling joist The fan housing A should be level and perpendicular to the joist Allow for thickness of ceiling board used in your application Position the fan housing A so the bott...

Page 6: ...ng box housing and reattach the wiring box cover CAUTION If your electrical wires do not match the colors listed consult a licensed electrician to determine what each house wire represents before conn...

Page 7: ...slots 8 EXISTING CONSTRUCTION INSTALLATION INSTRUCTIONS BEFORE INSTALLATION WARNING RISK OF ELECTRIC SHOCK Ensure the electricity to the wires you are working on is shut off Either remove the fuse or...

Page 8: ...7 1 2 in 7 3 4 i n 3 4 Attach the duct connector C to the fan housing A A C 4 5 Remove the three screws on the side of the fan housing A that hold the fan motor in place With the screws removed unplu...

Page 9: ...etermine what each house wire represents before connecting the fan Quick connector Wiring box cover Wiring box cover 7 8 Connect a 4 in circular duct to the duct connector on the fan housing A securin...

Page 10: ...4 hole 2 hole A B 12 13 Attach grille B by pinching the mounting springs and inserting them into the narrow rectangular slots in the fan housing A Turn on power source Test the unit Mounting springs H...

Page 11: ...ings and pulling the grille B down from the fan housing A Disconnect the connectors to remove the grille B from the fan housing A Wipe grille B with a damp cloth 1 A B 2 Remove dust and dirt from the...

Page 12: ...iries regarding warranty claims can be directed to 1 877 319 3757 7 30 a m 4 30 p m CST Monday Friday TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The fan seems louder than it should be The CFM is...

Page 13: ...l Servicio al Cliente 1 877 319 3757 de lunes a viernes de 7 30 a m a 4 30 p m hora est ndar central VENTILADOR CON LUZ MODELO 7141 80 G3 LEA Y GUARDE ESTAS INSTRUCCIONES ADJUNTE SU RECIBO AQU N mero...

Page 14: ...as Di metro del conducto 4 pulg Brillo del LED 1000 lumenes regulable Consumo el ctrico del motor 28 vatios Especificaciones del producto 14 Contenido del paquete 14 Materiales incluidos 14 Informaci...

Page 15: ...rcar seg n sea apropiado para la aplicaci n y conectarse a un circuito de derivaci n protegido GFCI Interruptor de circuito de falla a tierra 8 Este ventilador est dise ado para instalarse por lo meno...

Page 16: ...i n a continuaci n Conector r pido Cables de la casa Cables del producto NOTA el conector es reutilizable en cables s lidos del mismo o m s peque o calibre No reutilice el conector en cables trenzados...

Page 17: ...l techo La carcasa del ventilador A debe estar nivelada y perpendicular a la viga Permita el grosor de la placa de techo utilizada en su aplicaci n Coloque la carcasa del ventilador A de modo que el b...

Page 18: ...y vuelva a colocar la tapa de la caja de cableado PRECAUCI N si sus cables el ctricos no coinciden con los colores enumerados consulte a un electricista con licencia para determinar qu representa cad...

Page 19: ...RUCCIONES DE INSTALACI N DE CONSTRUCCI N EXISTENTE PREVIO A LA INSTALACI N ADVERTENCIA RIESGO DE DESCARGA ELECTRICA Asegurese de cortar el suministro electrico en los cables con los que trabajara Extr...

Page 20: ...cto C a la carcasa del ventilador A A C 4 5 Retire los tres tornillos en el lado de la carcasa del ventilador A que sujetan el motor del ventilador en su lugar Con los tornillos retirados desenchufe e...

Page 21: ...a antes de conectar el ventilador Conector r pido Tapa de la caja el ctrica Tapa de la caja el ctrica 7 8 Conecte un conducto circular de 4 pulg al conector del conducto en la carcasa del ventilador A...

Page 22: ...ro 2 agujero A B 12 13 Fije la rejilla B apretando los resortes de montaje e inser t ndolos en las ranuras rectangulares estrechas en la carcasa del ventilador A Encienda la fuente de alimentaci n Pru...

Page 23: ...y tirando de la rejilla B hacia abajo desde la carcasa del ventilador A Limpie la rejilla B con un pa o h medo 1 A B 2 Use una aspiradora para eliminar el polvo y la suciedad de la carcasa del ventil...

Page 24: ...alla debido a un defecto en el material o la mano de obra en cualquier momento durante los primeros CINCO a os de poseerlo elfabricante lo reemplazar sin cargos y con el franqueo pagado a su discreci...

Reviews: