HomeSeer HS-FLS100+ Manual Download Page 5

 

 

Sensor Event 

Floodlight 
behavior 

Z-Wave 
commands/notification 

Remark 

Lux 
sensor 

PIR 
sensor 

Daylight 

Trigger 

Off 

When Trigger: 
- Notification, 

PIR Trigger 

ON: Group 1

 

 
When timer expire: 
- Notification, 

PIR Trigger 

OFF: Group 1

 

Z-Wave 
command is 
sent even if 
floodlight is off 

Night, 
or   
Lux knob 
set to "T"   

Trigger 

On, until 
timer 
expires 

When Trigger: 
- Notification, 

PIR Trigger 

ON: Group 1 
- Switch Binary Report: 
Group 1 
- Basic Set On: Group 2

 

 
When timer expire: 
- Notification,

 PIR Trigger 

OFF:  Group 1 
- Switch Binary Report: 
Group 1 
- Basic Set Off: Group 2

 

 

 

 

Other Events 

Floodlight 
behavior 

Z-Wave 
commands/notification 

Remark 

1st power on 

On for 5 
seconds 

Notification:

 First Power Up: 

Group 1

 

 

 

Device Factory 
reset 

NA 

Device Reset Locally 
Notification: 

Group 1

 

 

 

 

Programming 

 

Z-Wave Plus Info 

Role Type 

Node Type 

Installer Icon 

User Icon 

Slave Always ON 
 

Z-Wave Plus 
node 

Sensor 
Notification 
Device Type 
(Home Security) 

Sensor 
Notification 
Device Type 
(Home Security) 

Association Command Class 

Group 

Max Node 

 

Version 

Protocol Library 

3 (Slave_Enhance_232_Library) 

Protocol Version 

5.3 (6.71.03) 

Firmware Version 

xVy (x=1, y=1 means 1V1)

 

Hardware Version 

 

Manufacturer 

Manufacturer ID 

Product Type 

Product ID 

0x0060 (Everspring) 

0x0010 

0x0001 

0x000C (HomeSeer) 

0x0201 

0x000B 

 

AGI (Association Group Information) Table 

Group 

Profile 

Command Class & Command (List) 

N bytes 

Group Name(UTF-8) 

General 

Device Reset Locally Notification 
Notification Report 
Binary Report 
Sensor Multilevel Report 
Basic Report 

Lifeline 

Control 

Basic Set 

PIR Control 

 

Notification Report 

Event 

Type 

Event 

Event Parameters 
Length 

Event 
Parameters 

First power up   

0x08 

0x01 

0x00 

 

PIR Trigger ON 

0x07 

0x08 

0x00 

 

PIR Trigger OFF 

0x07 

0x00 

0x01 

0x08 

 

Basic Report 

Parameter Number 

Size 

Range 

Default 

0/1 

1: send Basic Report 

0 : not sent Basic Report 

 

Summary of Contents for HS-FLS100+

Page 1: ...e controller when motion is sensed and when the LUX level changes Likewise the smart hub or home controller can send Z Wave commands back to the HS FLS100 to turn floodlights ON and OFF This added functionality provides a very high level of flexibility not typically available in conventional motion activated floodlights Smart Sensor Mode HS FLS100 can be installed and used simply as an outdoor mot...

Page 2: ...tart early during the day WARNING TURN OFF POWER BY REMOVING POWER FUSE OR TURNING OFF CIRCUIT BREAKER BEFORE INSTALLATION Taking down the existing floodlight 1 With mains supply turned off if possible remove the lamps from the bulb holders of the existing floodlight to avoid any damage during the installation 2 Carefully detach the floodlight from the wall by removing its mounting screws Keep all...

Page 3: ...n turn off It is now in Test Mode Walk Test The user can perform a walk test to ensure the PIR detector s range falls within the desired area of coverage 1 Walk through its PIR Detector coverage area The floodlight turns on when you move and turns off after approximately 5 seconds Wait for the floodlight to turn off before the next test 2 When you are satisfied with the coverage area you can now s...

Page 4: ... QR code label on the back of the unit on the insert card inside the packaging 6 Turn on the floodlight using the Z Wave controller to check if the auto inclusion is working properly If Auto Inclusion fails refer to the Troubleshooting section regarding Manual Inclusion Note HS FLS100 supports the latest S2 security o ffered by Z Wave certified controllers If your controller supports S2 please refe...

Page 5: ...ler Icon User Icon Slave Always ON Z Wave Plus node Sensor Notification Device Type Home Security Sensor Notification Device Type Home Security Association Command Class Group Max Node 1 1 2 4 Version Protocol Library 3 Slave_Enhance_232_Library Protocol Version 5 3 6 71 03 Firmware Version xVy x 1 y 1 means 1V1 Hardware Version 1 Manufacturer Manufacturer ID Product Type Product ID 0x0060 Everspr...

Page 6: ...ux level measured Tolerance of 30 lux Level above 250 will be read back as 250 Sensor Type Precision Scale Size Sensor Value 0x03 0 1 2 250 Command Classes The module supports Command Classes including COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COM...

Page 7: ...ion is complete 2 Press the Link button 3 times within 1 5 seconds to put the unit into inclusion mode Exclusion 1 Put the Z Wave Controller into exclusion mode 2 Press the Link button 3 times within 1 5 seconds to put the unit into exclusion mode Factory Reset This procedure should only be used when the controller is inoperable 1 Press the Link button 3 times within 1 5 seconds to put the unit in...

Page 8: ...the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or ope...