ZIR000 Instructions, Release 1.1
P/D 110805

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0685-01

2

Mounting the Detector

1.  Hold the provided mounting bracket in the location you want to mount the ZIR000. Mark the wall (or

ceiling) where the two screw holes will be drilled.

2.  Complete the following two steps if mounting in drywall, if there is no stud (or joist).

a.   Drill a pilot hole of 11/64”.
b.   Tap the provided wall anchors into the wall (or ceiling).

3.  Screw the mounting bracket to the wall (or ceiling) with the screws provided.
4.  Snap the ZIR000 onto the bracket.
5.  Adjust the vertical pattern angle per figure 2, if desired.

Fig 2

LENS can be adjusted to suit your needs by simply rotating the angle of the lens 180

o

 to change from wide

angle version (Default setting) to long range version if required.  The number of detection zones will change
between wide angle and long range.

WIDE ANGLE

  (Default Setting)

Angle: 105

o

 x 110

o

Distance: 39 feet (12 meters)

Zone Number: 64

LONG RANGE

  (Default S 180

o

)

Angle: 5

o

 x 5

o

Distance: 46 feet (14 meters)

Zone Number: 8

ADD TO NETWORK

To include or exclude the ZIR000 from the Z-Wave network, press the brown button marked “button” (inside)
when prompted by a Z-Wave controller. For ZIR000 to work properly over longer distances (i.e. communcate
via more nodes), add it to the network after you have added all other non-battery operated devices.  Now
replace the cover and screw.  The ZIR000 will stay “awake” for ten minutes when power is first applied to
allow time for configuration.
The ZIR000 can be configured to operate in 1 of 3 modes.
Those modes are:

•  

Lighting Mode (factory default)

•  

Alarm Mode

•  

Sensor Mode

To change the mode of operation:

For Lighting Mode

: Send a value of 0 to Configuration Parameter #17.

For Alarm Mode

: Send a value of 1 to Configuration Parameter #17.

For Sensor Mode

: Send a value of 2 to Configuration Parameter # 17.

Refer to your controller instructions on how to set Configuration parameters.

 

Summary of Contents for ZIR000

Page 1: ...ly Retain instructions for future use INSTALLATION Battery Installation and Sensitivity Selection 1 Remove the screw from the bottom of the enclosure 3 Select the sensitivity setting preferred for the ZIR000 by setting the corresponding jumpers on the electronic module Note that H option is the highest sensitivity while the L option is the lowest See Figure 1 4 Install the four AAA batteries into ...

Page 2: ...ng range WIDE ANGLE Default Setting Angle 105o x 110o Distance 39 feet 12 meters Zone Number 64 LONG RANGE Default Setting 180o Angle 5o x 5o Distance 46 feet 14 meters Zone Number 8 ADD TO NETWORK To include or exclude the ZIR000 from the Z Wave network press the brown button marked button inside when prompted by a Z Wave controller For ZIR000 to work properly over longer distances i e communcate...

Page 3: ... device that is associated into Group 2 will be sent an Alarm command when the housing of the ZIR000 is opened If the ZIR000 is configured to operate in Binary Sensor Mode any device that is associated into Group 2 will be sent an update when the housing of the ZIR000 is opened Group 3 Any device that is associated into Group 3 will be sent battery level indications at specific intervals There can...

Page 4: ...ion visit our web site at www act solutions com ABOUT ZIR000 S CERTIFICATION The ZIR000 is also certified to comply with applicable FCC and IC rules and regulations governing RF and EMI emissions This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference rece...