Door Requirements
3
Ensure that there is at least 45mm from the edge of the curtain to the edge of the bracket. If the roller door
drums are on the edge of the curtain or are of small diameter additional clearance maybe required.
If the drums are more than 60mm from the curtain edge or of small diameter extension poles maybe
required.
Different drum and bracket types may result in the minimum side room clearance not being possible and
extension poles being required. Ensure there is a power point near the opener.
Typical side room installation
Minimum side room installation
The maximum allowable door height is 3.5m with a maximum curtain area of 8m²
(door height in metres multiplied by the width in metres).
The maximum allowable door weight is 60kg.
Door area;
h x w = m
2
eg. 2.5 x 3 = 7.5m
2