Make sure that the specified wiring and wire cross-
sections are used when connecting to device ter-
minals.
Switch actuator:
Follow all technical specifications, especially the ma
-
ximum permitted switching capacity of the relay and
type of consumer to be connected, before connecting
the consumer! All load specifications refer to resistive
loads!
Shutter actuator:
The actuator is only suitable for 230 V a.c. motors!
Never connect three-phase a.c. motors or d.c. motors!
If motors are connected to the output in parallel
with the actuator, make sure to observe the motor
manufacturer's specifications. The motors can be da
-
maged otherwise.
Use only blinds or shutters with limit switch (mechani-
cal or electronic)!
Check the limit switch for the connected motors for
proper adjustment before starting the shutter actuator!
Dimming actuator:
Make sure to observe the applied load!
The dimmer is only suitable for light bulbs and for low
voltage NV halogen lamps with conventional transfor-
mers!
The devices are not intended to be isolated. The load
is not electrically isolated from the mains.
Fuse every transformer on the primary side according
to the manufacturer's specifications when working with
conventional transformers.
Use only safety transformers that conform with
DIN EN 61558-2-6 (VDE 0570 part 2-6).
Observe the installation instructions for installa-
tions in distribution systems.
3 Function
•
2 button connections
• Button connections can be configured as desired
and optional actuator channels can be assigned
(from other modules as well).
•
As many potential-free buttons as are necessary
can be connected to one button input.
• Non-volatile memory for configuration data.
•
Electrically isolated power and bus segments.