34
35
button for at least another four seconds.
The LED will now start to flash red faster. Release the
teach-in button to complete the reset procedure; the
LED lights up red continuously for around three sec-
onds to confirm that the reset has been successful.
Possible error messages:
This error can only occur if you have a central
control unit to which you have taught-in the
device.
If the LED does not start to flash when the button
has been held down for five seconds, but lights up
continuously instead, the device cannot be reset! In
this case, coding is activated using a system security
key that differs from the one supplied with the product.
To reset the sensor, you will have to use the configura
-
tion software for resetting the central control unit! The
procedure to follow is described in the manual for the
central control unit software.
9 Maintenance and cleaning
Clean the housing and the electrodes using a soft and
dry cloth. You may dampen the cloth a little with water
in order to remove more stubborn marks. Do not use
any detergents containing solvents, as they could cor-
rode the plastic housing and label.
10 Technical specifications
Radio frequency:
868.3 MHz
Typ. open air range:
100 m
Power supply:
2 x 1.5 V LR6 batteries
(mignon/AA)
Battery life:
up to three years
Degree of protection:
IP65
Dimensions (W x H x D): 115 x 65 x 55 mm
Subject to technical alterations.
Instructions for disposal
Do not dispose of the device with regular
domestic waste. Electronic devices must be
disposed of in accordance with the Waste
Electrical and Electronic Equipment Directive
via local disposal points for electronic waste.
The CE Marking is simply an official symbol