InStrUCtIonSForUSe– haIrreMoVaL
N.B. It is recommended to carry out the Spot test (page 5) at least 48hrs prior to treatment to choose a
safe treatment level for your skin.
1. Priortouse,makesureyourskinisshaved,cleananddry(freeofanyresiduesuchaspowders,creams,
makeup,antiperspirantsordeodorants).
Warning!
neVeruseflammableliquidssuchasalcoholoracetonetocleantheskinbeforeusingduo.
2. havingfollowedduoset-upstepsabove,pressthepowerbutton
q
toturnonthedevice.theLed
indicatorforlevel1willilluminate.
3. thedevicesetsitselfonthelowestenergylevel.Usethepowerbuttontoincreasetheenergyleveltoreach
theleveldeterminedinthespottestandaccordingtoyourconvenience.theenergylevellightswilllight
upblue(aFt)/white(IPL)accordingtotheselectedlevel.
4. Placetheapplicatortreatmentwindowontherequiredtreatmentareawithfullcontacttotheskin(the
applicatorwillnottriggerapulseifthereisnotfullskincontactandthegreen‘ready’indicatorlightwill
stopflashingbutremainilluminatedwhenthedeviceisingoodcontactwiththeskin).
5. dependentontheenergylevelselectedthedevicecanbeusedintwoways:
Freeglide method (AFT):
thisisthemethodusedonenergylevels1-3.holdthepulsebuttondown
continuouslyandslowlymovethedeviceovertheskinmaintainingconstantcontact.Inthismodeitis
necessarytorepeatedlypassthedeviceoverthesameareaupto5timestoensuremaximumcoverage
N.B.
thehigherthelevelthesloweryouwillneedtoglidethedevice.thisisbecausethemoreenergy
released,theslowerthepulserate.
Single shot method (IPL):
thisistherecommendedmethodtouseforhighenergylevels4-5.Withthe
treatmentwindowincontactwiththeskin,pressthetriggerbuttonandwaitfortheflash.onlyshootonce
beforemovingthedevicetothenexttreatmentareaensuringtherearenogapsoroverlapsinthetreated
area.WaitforthestatusindicatorLedtostopflashing(upto3.5seconds)beforepressingthepulsebutton
again.
duringbothtreatmentmethodsyouwillseeabrightflash,hearapoppingnoiseandmayfeelamild
stingingand/orheatsensation.
6. repeatsteps4and5untilallthechosenareahasbeentreated.
The product should not be used for more
than 30 minutes at one time. After 30 minutes are up, switch the device off and unplug from the wall.
NB:
Ifthedeviceisleftonbutnotusedforapproximately3minutesitwillautomaticallyswitchitselfoff.If
thishashappened,pressthepowerbuttontoturnthedevicebackon.
Facial treatment
Only use the facial adaptor to treat the face (*available for purchase separately)
thefacialskinisasensitiveareathatrequiresspecialcareandcaution.Makesureyoufollowallinstructions
andsafetyprecautionscarefullyinordertoavoidadverseeffects.tomaximisesafety,bothaFtandIPLpower
levelswillfunctioninsingleshotmodeforgreatercontrolwhentreatingtheface.thefacialadaptorincludes
apressuresensor,thetreatmentwindowmustbeingoodcontactwiththeskinotherwisethedevicewillnot
flash.
Start the treatment on level 1 and increase only if the treatment is comfortable.
thefacialcartridgeisavailabletobuyseparately,itisrecommendedthatyouusethiswhenperformingfacial
treatmentasitisspeciallydesignedtofitsmallerareassuchasthetoplip.
Fitting the facial adaptor
(*sold separately)
thefacialadaptorattachestotheproductinthesamewayasthestandardcartridge.Seepage10for
instructions.
Warning!
1) donotusethedeviceonthefaceabovethecheekline,aroundtheeyes,eyebrowsoreyelashesasthis
couldcauseseriouseyedamage.
2) Protectivegogglesareincludedwiththefacialcartridge(soldseparately).theseshouldbewornto
decreasediscomfortwhentreatingneartheeyes.
3) donotusethedevicetotreathairgrowthinthenoseandears(seepage3).
4) MakesureyoudoaSpottest48hourspriortotreatment.theSpottestshouldbedoneinahair-freearea
suchasbelowtheearorthesideofthenecktodeterminetheenergylevel.
IB-IPLHH160GB-