IMPORTANT SAFETY INSTRUCTIONS:

WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE 
PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, 
INCLUDING THE FOLLOWING:

READ ALL INSTRUCTIONS BEFORE USING

DANGER

 

– TO REDUCE THE RISK OF ELECTRIC SHOCK:

• Always unplug the air cleaner from the electrical outlet immediately after using and  
  before cleaning.
• Keep cord away from heated surfaces
• Always place the air cleaner on a firm, level surface.
• Always place the air cleaner at least six (6) inches away from walls and three (3) feet  
  from heat sources such as stoves, radiators, or heaters.
• DO NOT operate where aerosol (spray) products are being used or where oxygen is  
  being administered.
• DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
• DO NOT use while bathing or in the shower.
• DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
• DO NOT place in or drop into water or other liquid.
• NEVER use pins or other metallic fasteners with this appliance.
• Keep dry - DO NOT operate in a wet or moist condition.
• This appliance is designed for personal, non-professional use only.

• Check your air cleaner cord and plug connections.
  a) Faulty wall outlet connections or loose plugs can cause the outlet or plug to    
  overheat. Be sure the plug fits tight in the outlet.
  b) This air cleaner draws 12.5 amps during operation. To prevent overloading a   
  circuit, do not plug the air cleaner into a circuit that already has other appliances  
  working.

CAUTION: It is normal for the plug to feel warm to the touch; however,
a loose fit between the AC outlet (receptacle) and plug may cause
overheating and distortion of the plug. Contact a qualified electrician
to replace loose or worn outlet.

WARNING

 

-

 TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC 

SHOCK OR INJURY TO PERSONS:

•  Extreme caution is necessary when any air cleaner is used by or near children or 

invalids  and whenever the air cleaner is left operating and unattended.

•  Always unplug the air cleaner when not in use.
•  Do not operate the air cleaner with a damaged cord or plug, or after the air cleaner 

malfunctions, has been dropped or damaged in any manner. Discard the air cleaner 
or return to HoMedics Consumer Relations for examination, electrical or mechanical 
adjustment, or repair.

• This air cleaner is not intended for use in bathroom, laundry areas and similar moist 

indoor locations. Never locate air cleaner where it may fall into a bathtub or other 
water container.

•  Do not run cord under carpeting. Do not cover cord with throw rugs, runners or 

similar coverings. Do not route cord under furniture or appliances.  Arrange cord 
away from traffic areas where it can be tripped over.

• To disconnect the air cleaner, first turn controls to the OFF position, then remove 

plug from outlet. 

• Do not tilt or move the air cleaner while it is in operation.  Shut off and remove plug 

from outlet before moving.

• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as 

this may cause an electric shock or fire, or damage the air cleaner.

Summary of Contents for AR-20

Page 1: ...ricado aprobado y o autorizado o la reparación de productos dañados por estas modificaciones no están cubiertos bajo esta garantía LA GARANTÍA AQUÍ ESTABLECIDA SERÁ LA ÚNICA Y EXCLUSIVA GARANTÍA NO HABRÁ NINGUNA OTRA GARANTÍA EXPRESA NI IMPLÍCITA INCLUYENDO NINGUNA GARANTÍA DE COMERCIALIZACIÓN O APTITUD NI NINGUNA OTRA OBLIGACIÓN POR PARTE DE LA COMPAÑÍA CON RESPECTO A PRODUCTOS CUBIERTOS POR ESTA...

Page 2: ...r cleaner into a circuit that already has other appliances working CAUTION It is normal for the plug to feel warm to the touch however a loose fit between the AC outlet receptacle and plug may cause overheating and distortion of the plug Contact a qualified electrician to replace loose or worn outlet WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Extreme caution is ne...

Page 3: ...his device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user authority to operate the equipment Note This equipment has been tested a...

Page 4: ...ntact a qualified electrician DO NOT attempt to defeat this safety feature To do so could result in an electric shock hazard Control Panel Operating Instructions Turning the Unit On Take the air cleaner out of the box and remove the clear protective plastic bag Place the air cleaner on a firm level surface Before turning the air cleaner ON you need to confirm that the filter is firmly in place and...

Page 5: ...o hours 4 four hours 6 six hours 8 eight hours 10 ten hours and 12 twelve hours To activate the timer and select a time setting press TIMER on the control panel Each time the TIMER function is pressed it will switch between settings in a repeating cycle as follows 2 hours 4 hours 6 hours 8 hours 10 hours 12 hours OFF Press again and the cycle begins again The selection will light up on the LED con...

Page 6: ... the HEPA filter is ready to be cleaned the LED CLEAN FILTER indicator will light up on the control panel Once the permanent HEPA filter has been cleaned press and hold the CLEAN FILTER button to reset the Indicator until it beeps Cleaning the HEPA Filter Make sure that the air cleaner is turned OFF and unplugged from the outlet before cleaning 1 Open the front grill by gently pulling on the tabs ...

Page 7: ...ven surface Troubleshooting 5 Place the clean HEPA filter back in the main unit making sure that it is firmly seated inside the unit 6 Place the tabs at the bottom of the grill plate into the base of the unit Gently push the grill plate back into place until you hear a click sound indicating that the grill is firmly latched DO NOT USE WATER OR ANY HOUSEHOLD CLEANERS OR DETERGENTS TO CLEAN THE HEPA...

Page 8: ...ics This warranty is effective only if the product is purchased and operated in the country in which the product is purchased A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed manufactured approved and or authorized or repair of products damaged by these modifications is not covered under this warranty THE WARR...

Page 9: ...a caliente al tacto sin embargo un encaje flojo entre el tomacorriente de CA receptáculo y el enchufe puede provocar el recalentamiento y la deformación del enchufe Póngase en contacto con un electricista calificado para reemplazar el tomacorriente flojo o gastado ADVERTENCIA PARA REDUCIR EL RIESGO DE QUEMADURAS CHOQUE ELÉCTRICO INCENDIO O LESIONES A LAS PERSONAS Se debe ser extremadamente precavi...

Page 10: ...RA SU FÁCIL REFERENCIA Especificaciones técnicas Características principales en el aire HEPA Cleaner Professional Panel de control Unidad principal HEPA Filter Frente PLAT Parrilla Tensión de entrada 120V Frecuencia nominal 60 HZ Potencia 65 vatios Peso 11 25 lbs Nivel de Ruido 60 dB Unidad de altura 18 5 pulgadas Declaración de la FCC Este dispositivo cumple con la Parte 15 de las Normas FCC El f...

Page 11: ...ente en el tomacorriente invierta el enchufe Si aún así no encaja póngase en contacto con un electricista calificado NO intente destruir esta característica de seguridad Hacerlo podría tener como resultado un peligro de choque eléctrico Panel de control Instrucciones de uso Para encender la unidad Retire el limpiador de aire de la caja y quite la bolsa plástica protectora trasparente Coloque el li...

Page 12: ...a gaveta NOTA siempre mantenga la pila y el control remoto fuera del alcance de los niños 1 Encendido apagado y configuración de velocidad To turn the air cleaner on press the ON OFF button on the control panel When the air cleaner is on the LED light in the ON OFF button on the control panel will be lit and the air cleaner will start to operate on LOW speed Once the air cleaner is ON press the SP...

Page 13: ...e aire La placa de la rejilla puede limpiarse con un paño húmedo o con el accesorio de cepillo de su aspiradora NO USE AGUA CERA LUSTRADOR NI NINGUNA SOLUCIÓN QUÍMICA Indicador de limpiar filtro El limpiador de aire cuenta con un indicador CLEAN FILTER limpiar filtro para avisar al usuario cuando sea momento de limpiar el filtro HEPA aproximadamente cada 2 800 horas de uso Cuando el filtro HEPA es...

Page 14: ...nidad Conecte la unidad Pulse el botón POWER a conectar la alimentación Revise los circuitos fusibles pruebe con un toma diferente Reducción del flujo de aire filtrado o pobres La parrilla delantera se puede bloquear El filtro HEPA puede estar obstruida Verifique que nada esté bloqueando la rejilla frontal y salida de aire Revise y limpie el filtro Reemplace el filtro El ruido excesivo La unidad n...

Reviews: