7
G
B
CLEANING AND MAINTENANCE
We recommend that the air cleaner be cleaned at least once a month and before storage.
Turn the air cleaner OFF at the main switch and unplug it from the outlet.
Use a dry cloth to clean the external surfaces of the air cleaner.
The grill plate may be cleaned with a damp cloth or the brush attachment of your vacuum cleaner.
DO NOT USE WATER, WAX, POLISH OR ANY CHEMICAL SOLUTION
Clean Filter Indicator
The air cleaner is equipped with a CLEAN FILTER indicator to let the user know when it is time to clean the
HEPA filter, about every 2,800 hours of use. When the HEPA filter is ready to be cleaned, the LED CLEAN FILTER
indicator will light up on the control panel.
Once the HEPA filter has been cleaned, press and hold the CLEAN FILTER indicator to reset until the LED
indicator light flashes and turns off.
Cleaning the HEPA Filter
Make sure that the air cleaner is turned OFF and unplugged from the outlet before cleaning.
Fig.5
Fig.6
Fig.8
Fig.9
Fig.7
Fig.10
1. Open the front grill by gently pulling on the tabs on either side of the top of the grill plate (Fig. 5).
2. Open the plate outward until the tabs at the bottom of the grill plate easily slide away. from the unit (Fig 6).
3. Remove the HEPA filter from the main unit (Fig. 7).
4. Use the brush attachment with your vacuum cleaner. Run the attachment along both sides of the HEPA
filter, cleaning thoroughly between the accordion folds of the filter (Fig. 8).
5. Place the clean HEPA filter back in the main unit, making sure that it is firmly seated inside the unit (Fig. 9).
6. Place the tabs at the bottom of the grill plate into the base of the unit. Gently push the grill plate back into
place until you hear a click sound indicating that the grill is firmly latched (Fig.10).
DO NOT USE WATER OR ANY HOUSEHOLD CLEANERS OR DETERGENTS TO CLEAN THE HEPA FILTER.
It is recommended that you replace the HEPA filter every 18 months to maintain the optimal
performance of your air cleaner. To purchase the HEPA replacement filter, go back to your retailer
(where you purchased your air cleaner) or visit www.homedics.co.uk
IB-AR-10A-0614-04_Layout 1 11/06/2014 16:16 Page 7
Summary of Contents for AR-10A-EU
Page 2: ...IB AR 10A 0614 04_Layout 1 11 06 2014 16 16 Page 2 ...
Page 93: ...IB AR 10A 0614 04_Layout 1 11 06 2014 16 17 Page 93 ...
Page 94: ...IB AR 10A 0614 04_Layout 1 11 06 2014 16 17 Page 94 ...
Page 95: ...IB AR 10A 0614 04_Layout 1 11 06 2014 16 17 Page 95 ...
Page 96: ...IB AR 10A 0614 04 IB AR 10A 0614 04_Layout 1 11 06 2014 16 17 Page 96 ...