c. gas connection (continued)

A small amount of air will be in the gas supply lines. When first lighting the appliance it will take a short time for the air to purge 
from the lines. subsequent lighting of the unit will not require such purging. 

DANGER

NOTICE

CAUTION

WARNING

fIRe RISk.
expLOSION RISk:

     • Gas build-up during line purge may ignite.
     • Purge should be performed by a qualified technician. 
     • ensure adequate ventilation.
     • ensure there are no ignition sources such as sparks or open flames.

DANGER

NOTICE

CAUTION

WARNING

CHeCk fOR gAS LeAkS.
fIRe RISk.
expLOSION RISk.
ASpHyxIATION RISk: 

     • Check all fittings and connections.
     • Do not use open flame.
     • After the gas line installation is complete, all connections must be tightened and checked for leaks with a non-corrosive,      

 

        commercially-available leak check solution. Once leak check test is complete, be sure to rinse off all remaining leak 

 

        check solution from the gas piping systems.
Fittings and connections may have loosened during shipping and handling.

d. lp gas supply

 

     • The pressure regulator and hose assembly supplied with LP models must be used. Replacement pressure regulators and hose 

 

        assemblies must be those specified in this manual.
     • The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the specifications for LP 
        gas cylinders of the U.s. Department of Transportation (DOT).
     • Cylinders must be stored outdoors in a well-ventilated area out of the reach of children. Disconnected cylinders must have 

 

        threaded valve plugs tightly installed and must not be stored in a building, garage, or any other enclosed area.
     • storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply (natural gas line or LP gas 

 

        cylinder).
     • The LP gas cylinder supply system must be arranged for vapor withdrawal.
     • The LP gas cylinder used must include a collar to protect the cylinder valve.
     • When an LP model is not in use, the LP gas must be turned off at the supply cylinder.
     • The specific size and capacity of the cylinder(s) to be used: 20 lb or hard plumbed to propane tank.

IMpROpeR INSTALLATION, ADjUSTMeNT, ALTeRATION SeRVICeS, OR MAINTeNANCe CAN CAUSe INjURy OR pROpeRTy 
DAMAge. RefeR TO AND UNDeRSTAND THIS MANUAL. fOR ASSISTANCe OR ADDITIONAL INfORMATION CONSULT A 
qUALIfIeD INSTALLeR, SeRVICe AgeNCy, LICeNSeD TeCHNICIAN, OR THe gAS SUppLIeR. 

4

gas hook-up & information

Summary of Contents for CF-12

Page 1: ...2 0 2 1 c r y s t a l f i r e c r y s t a l f i r e P L U S b u r n e r f i r e t a b l e m a n u a l...

Page 2: ...SEVERE BURNS MAY RESULT CLOTHING IGNITION MAY RESULT Glass and other surfaces are hot during operation and cool down Keep children away CAREFULLY SUPERVISE children near this appliance Alert children...

Page 3: ...ulations Congratulations on selecting a Homecrest Outdoor Living decorative gas appliance The fire table you selected features a Crystal Fire Crystal Fire Plus burner and is designed to provide the ut...

Page 4: ...4 www homecrest com...

Page 5: ...cause slight discoloration of the cosmetic surface See page 15 for details cf 12 Round Burner Assembly Black Propane Hose with Regulator Flexible Metal Gas Line 55 Orifice LP Gas 49 Orifice Natural Ga...

Page 6: ...nd CSA 2 41 2017 for Canada and has been listed by Underwriters Laboratory UL for installation and operation as described in these installation and operating instructions The installation must conform...

Page 7: ...ty and benefit DANGER NOTICE CAUTION WARNING Asphyxiation Risk This gas appliance is for outdoor use in a well ventilated space This unit must not be installed inside an enclosed structure or unvented...

Page 8: ...ank valve marked USE WITH TYPE 1 Inspect the hose shipped with the appliance for any damage Do not use if there is evidence of damage Connect the end of the hose onto the ON OFF gas valve of the appli...

Page 9: ...ing system at test pressures equal to or less than 1 2 psi 3 5 kPa c gas connection Note Have the gas supply installed in accordance with local building codes if any If not follow ANSI 223 1 Installat...

Page 10: ...els must be used Replacement pressure regulators and hose assemblies must be those specified in this manual The LP gas supply cylinder used with LP models must be constructed and marked in accordance...

Page 11: ...pane burner orifice installed in the burner and install supplied natural gas orifice 6 Loosen air shutter with Phillips head screwdriver and fully close air shutter Tighten screw when air shutter is p...

Page 12: ...re or explosion D Do not use the appliance if any part has been underwater Immediately call a qualified service technician to inspect the appliance and replace any part which has been underwater E The...

Page 13: ...or not installed between the LP tank and the appliance Close LP tank and manual shut off valves Open LP tank valve first THEN the manual shut off valve B Excessive media buildup around igniter Ensure...

Page 14: ...on 1 Verify all gas connections are tight and leak free 2 Clean burner top inspect for plugged ports corrosion or deterioration Replace burner if necessary 3 Inspect for flame problems 4 Verify air sh...

Page 15: ...r in store demonstrations Regulator Kit LP Tank horizontal LP tank 005269 20 lbs Use with all 19 height fire pits sold separately 12 25 burner cover 91007 Smooth Aluminum Glass Guards accessories 14 5...

Page 16: ...est product features trends beauty photography and more connect with us take a deeper dive Looking for more information on Homecrest Outdoor Living Visit the Homecrest modern web experience where you...

Reviews: