DESCALING
If hard water is used, limescale will eventually build up in the water tank and in the water-contact parts of the unit. Limescale deposited on
the oscillator impedes normal operation.
We suggest you to
1.
Use distilled water.
2.
Clean the water tank and the oscillator weekly.
3.
Change the water frequently.
4.
If you are not planning to use the appliance for a longer period of time, clean the entire appliance, and store it dry.
Water tank cleaning, descaling
1.
Switch off the humidifier, then disconnect the power by unplugging the power plug.
2.
Rinse the water tank with slightly vinegary water (1 tablespoon vinegar in 1 glass of water), then also with clean water.
Cleaning, descaling water tank
1.
Switch off the humidifier, then disconnect the power by unplugging the power plug.
2.
Drip 5-10 drops of vinegar on the oscillator, wait 2-5 minutes.
3.
Clean the oscillator's surface with an appropriately soft material, e.g. cotton swab.
4.
Rinse with clean water.
TROUBLESHOOTING
Waste equipment must not be collected separately or disposed of with household waste because it may contain components
hazardous to the environment or health. Used or waste equipment may be dropped off free of charge at the point of sale, or at any
distributor which sells equipment of identical nature and function. Dispose of product at a facility specializing in the collection of
electronic waste. By doing so, you will protect the environment as well as the health of others and yourself. If you have any
questions, contact the local waste management organization. We shall undertake the tasks pertinent to the manufacturer as
prescribed in the relevant regulations and shall bear any associated costs arising.
DISPOSING OF ALKALINE AND
RECHARGEABLE BATTERIES
Batteries, whether alkaline or rechargeable, must not be handled together with regular
household waste. It is the legal obligation of the product's user to dispose of batteries at a nearby collection center or at a retail
shop. This ensures that the batteries are ultimately neutralized in an environment-friendly way.
TECHNICAL
PARAMETERS
power supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 V ~ / 50 Hz /
75
W
protection class: . . . . . . . . . . . . . . . . . . . . . . . . . . II.
fan blade diameter: . . . . . . . . . . . . . . . . . . . . . . . . 40 cm
3
maximum air mass volume:. . . . . . . . . . . . . . . . . . F =
51,8
m /min
fan input power:. . . . . . . . . . . . . . . . . . . . . . . . . . . P = 4
7,8
W
3
service value: . . . . . . . . . . . . . . . . . . . . . . . . . . . . SV = 1,
1
(m /min)/W
power consumption in standby mode:. . . . . . . . . . P = 0,2 W
SB
fan acoustic power level: . . . . . . . . . . . . . . . . . . . . L = 5
7
dB(A)
WA
maximum air speed: . . . . . . . . . . . . . . . . . . . . . . . c =
2,2
m/sec
service value standard: . . . . . . . . . . . . . . . . . . . . . IEC 60897:1986 (corr. 1992)
water tank volume: . . . . . . . . . . . . . . . . . . . . . . . . 3
,2
l
humidification: . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 200 ml/h
length of power cable: . . . . . . . . . . . . . . . . . . . . . . 1,
7
m
outside dimensions:. . . . . . . . . . . . . . . . . . . . . . . . 4
4
x 12
5
x
40
cm
weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8,7
kg
Malfunction
Possible solution
Fan doesn not switch on.
Check the power supply.
The fan doesn not respond to the remote control's signals. Operation range of the remote control is max. 6 m.
Replace the batteries of the remote control.
Humidifying is not working.
Fill up the water tank with ionized water.
Descale the oscillator.