6.

 

Connect the conduction pipe (9) to the humidifier disc (1).

7.

 

Assemble the ultrasonic evaporator in the order shown in Figure 2.

8.

 

Insert the bottom of the conduction tube into the cover of the ultrasonic evaporator. 

9.

 

According to Figure 4., fill the water tank up with water. Use deionized water, which is not warmer 

than 40 °C. Insert the water tank to the appliance.

10.

 

Insert 2 pcs AAA size batteries.

11.

 

The device now can be connected to the mains outlet.

CAUTION: RISK OF ELECTRIC SHOCK!

 

Do not attempt to disassemble o

r

 modify the unit or its accessories. In case any part is damaged, 

immediately power off the unit and seek the assistance of a specialist.
In the event that the power cable should become damaged, it should only be replaced by the 
manufacturer, its service facility or similarly qualified personnel.

FEATURES

• 

humidifier fan 

• 

 all functions are remote controllable 

• 

 adjustable fan in 3 stages

 •

 continuously adjustable humidification 

• 

natural wind 

and night mode 

 oscillation (75°)

 •

 7,5 hour fan switch-off timer 

• 

 humidification that can be switched on independently from the fan 

FIGURE

 1

:

• 

1. 

frontside of the guard grille with the humidifier disc 

• 

2. 

blade fixer nut

 • 

3. 

fan blade

 • 

4.

 grille-fixer ring

 • 

5. 

grille-fixer nut

 • 

6. 

backside of 

the guard grille 

• 

7. 

motor

 • 

8. 

head tilt angle adjustment

 • 

9. 

conduction pipe 

• 

10. 

appliance body

 • 

11. 

push-buttons

 • 

12. 

tubular frame 

fixer screw 

 • 

13. 

power cable

 • 

14.

 tubular frame

 • 

15. 

base

 • 

16.

 water tank

 • 

17. 

humidifier power cord 

 • 

18. 

mist control

 • 

19.

 ultrasonic 

oscillator

 • 

20.

 evaporator cover

FIGURE 

3

.

Control panel:

 

 

21.

 

oscillation indicator

 • 

22.

 

humidification indicator

 • 

23.

 

switched-on state indicator

 • 

24.

 

push-buttons

 • 

25.

 

wind

 

operation modes

 • 

26.

 

fan speed

 • 

27.

 

switch-off timer indicator 

Buttons of the remote control and the control panel: 

• 

SPEED /ON:

 switch on, fan speed

 • 

MODE:

 wind modes 

• 

TIMER:

 switch-off timing

 

• 

SWING: 

oscillation switch

 • 

MIST: 

humidification 

switch on/off

 

• 

OFF:

 fan switch-off

FUNCTIONS OF THE DEVICE, USE

Connect the device to a standard 230 V~ / 50 Hz power outlet.

 

The POWER LED on the unit lights up.  

 

Pressing the 

SPEED/ON

 button starts the fan at the lowest stage. 

Fan mode also features 

humidification, timing, oscillation

 and also

 wind function.

 

Use the 

SPEED

 button to select the fan speed.  

 

Press 

TIMER 

button to select the period between 0,5 and 7,5 hours, after which the unit will switch off. The remaining time is the sum of 

the periods indicated by the illuminated 

LED

s. 

 

Use the 

MODE 

button to select the natural wind mode (Nature), or the night mode (Sleep). For normal fan mode, press the MODE button 

once again (Normal).

 

Use 

SWING

 button to switch on/off the right-left oscillating movement of the fan.  

 

Use

 MIST

 button to start ultrasonic cold humidification.  

Intensity can be set continuously adjusted with the mist control (18). Switched-on condition is indicated by the blue colored MIST LED. If 
the water tank runs out of water, it is indicated by the red LED under the mist control (18), the function stops at the same time. 
After switching it off with the remote control, all settings except the power off timer are memorized. 
After a power failure, the unit forgets all previous settings and goes into standby mode. 

CLEANING

In order to ensure optimum functioning, the unit may require cleaning at least once a month, depending on the manner of use and degree 
of contamination.

1.

 

Prior to cleaning switch off and power off the unit by unplugging it from the electric outlet!  

2.

 

Use a slightly moistened cloth to clean the unit's exterior. Do not use any aggressive cleaners. Avoid getting water inside of and on the 

electric components of the appliance!

3.

 

Remove the water tank. By loosening the water outlet screw, empty the water from the device. Clean the inside of the device with a dry, 

lint-free cloth.

4.

 

Reinstall the fan!

Summary of Contents for SFM 41/BK

Page 1: ...instruction manual SFM 41 BK eredeti haszn lati utas t s n vod na pou itie manual de utilizare uputstvo za upotrebu navodilo za uporabo n vod k pou it instrukcja u ytkowania uputa za uporabu...

Page 2: ...rys 1 1 slika figure 2 bra obraz figura 2 skica skica obr zek rys 2 slika 2 2 2 2 2 2 figure 4 bra obraz figura 4 skica skica obr zek rys 4 slika 4 4 4 4 4 4 figure 3 bra obraz figura 3 skica skica 3...

Page 3: ...me switch it off then remove the power plug from the outlet then empty the water tank 14 If any irregular operation is detected e g unusual noise or burnt odor from unit immediately switch it off and...

Page 4: ...ftheremotecontrolandthecontrolpanel SPEED ON switch on fan speed MODE wind modes TIMER switch off timing SWING oscillation switch MIST humidification switchon off OFF fanswitch off FUNCTIONSOFTHEDEVIC...

Page 5: ...you will protect the environment as well as the health of others and yourself If you have any questions contact the local waste management organization We shall undertake the tasks pertinent to the ma...

Page 6: ...ztart lyt 14 Ha b rmilyen rendelleness get szlel pl szokatlan zajt hall a k sz l kb l vagy gett szagot rez azonnal kapcsolja ki s ramtalan tsa 15 gyeljen arra hogy a ny l sokon kereszt l semmilyen t r...

Page 7: ...0 Hz h l zati csatlakoz aljzatba Ekkor a k sz l ken a POWER LED vil g tani kezd A SPEED ON gomb megnyom sakor elindul a ventil tor a legkisebb fokozaton Ventil tor zemm dhoz pluszban v laszthat a p r...

Page 8: ...lakoz k bel hossza 1 7 m befoglal m rete 44 x 125 x 40 cm res t mege 8 7 kg Hibajelens g A hiba lehets ges megold sa nem kapcsol be a ventil tor ellen rizze a h l zati t pell t st a ventil tor nem rea...

Page 9: ...ti z pach sp leniny ihne vypnite pr stroj a odpojte od elektrickej siete 15 Dbajte na to aby sa cez otvory nedostal do zariadenia iadny predmet alebo tekutina 16 Chr te pred prachom parou priamym slne...

Page 10: ...iba na dia kovom ovl da i TIMER asova vypnutia SWING sp na oscil cie MIST za vypnutie zvlh ova a OFF vypnutie ventil tora FUNKCIE POU VANIE PR STROJA Pripojte pr stroj do normalizovanej 230 V 50 Hz s...

Page 11: ...adom na jeho r z a funkciu V robok m ete odovzda aj miestnej organiz cii zaoberaj cej sa likvid ciou elektroodbadu T m chr nite ivotn prostredie udsk a teda aj vlastn zdravie Pr padn ot zky V m zodpo...

Page 12: ...tensiuneadere ea 12 Dac nu utiliza i produsul o perioad mai lung de timp opri i aparatul i scoate i l de sub tensiunea de re ea prin extragereafi eidinpriz igoli irecipientuldeap 14 ncazul ncaresesiza...

Page 13: ...ez ventilator 27 semnalizare temporizator oprire Butoanele telecomenzii i al panoului de control SPEED ON pornire vitez ventilator MODE moduri de func ionare v nt numai pe telecomand TIMER temporizato...

Page 14: ...u caracteristici i func ionalit i similare Poate fi de asemenea predat la punctele de colectare specializate n recuperarea de eurilor electronice Prin aceasta proteja i mediul nconjur tor s n tatea Du...

Page 15: ...upadne ili ucuri u ure aj 16 titite od pra ine pare vlage direktnog uticaja sunca i direktne toplote 17 Pre i enja uvek isklju ite ure aj iz struje 18 Ure aj ni priklju ni kabel nikada ne dodirujte mo...

Page 16: ...remena nakom ega e se ure aj automatski isklju iti interval za pode avanje je od 0 5 7 5 sati Preostalo vreme se indikuje svetle im LED diodama Tasterom MODE mogu e je odabrati funkciju prirodnog vetr...

Page 17: ...ik treba da se stara o pravilnom bezbednom odlaganju istro enih baterija i akumulatora Ovako se mo e tititi okolina obezbediti da se baterije i akumulatori budu na pravilan na in reciklirani TEHNI KI...

Page 18: ...nevylila 12 P edt m ne budete s ventil torem manipulovat jej v ka d m p pad odpojte z elektrick s t 13 Nebudete li ventil tor del dobu pou vat nejprve jej vypn te nap jec kabel vyt hn te ze z suvky ve...

Page 19: ...c panel 21 kontrolkaoscilace22 kontrolkafunkcezvlh ov n vzduchu23 kontrolkazapnut hostavu 24 tla tka25 provozn re imyv tru26 rychlostn stupn ventil toru27 kontrolka asovan hovyp n n Tla tkanad lkov mo...

Page 20: ...kov ch distributor kte se zab vaj prodejem za zen kter maj stejn parametry a funkci Odevzdat m ete i na sb rn ch m stech ur en ch ke shroma ov n elektronick ho odpadu Tak chr n te ivotn prost ed sv zd...

Page 21: ...a strani objekti i teku ine ne dospiju u ure aj kroz otvore 16 Za titite od pra ine vlage sun eve svjetlosti i direktnog toplinskog zra enja 17 Isklju ite ure aj isklju uju i je iz elektri ne uti nice...

Page 22: ...da vjetar TIMER timer isklju enja SWING oscilacija MIST uklju ivanje isklju ivanjeovla ivanja OFF isklju enjeventilatora FUNKCIJEURE AJA UPORABA Priklju iteure ajstandardnuna230V 50Hzelektri nuzidnuut...

Page 23: ...itanja obratite se lokalnoj organizaciji za odlaganje otpada Prihva amo na sebe zakonom odre ene obveze koje su propisane za proizvo a e i sve tro kove koji su u vezi s tim NEUTRALIZACIJA BATERIJA AKU...

Page 24: ...em ostro no ci aby nie wychlapa wody 12 Za ka dym razem kiedy zamierzamy przemie ci urz dzenie zawsze nale y je od czy od sieci zasilaj cej 13 W przypadku d u szego okresu nie u ywania urz dzenia nale...

Page 25: ...ia19 oscylatorultrad wi kowy 20 pokrywageneratorapary Rysuneknr3 Panelsterowania 21 kontrolkapracyoscylatora 22 kontrolkanawil ania 23 kontrolkastanuw czeniaurz dzenia 24 przyciski 25 trybysymulacjiwi...

Page 26: ...d w komunalnych poniewa mog one zawiera komponenty niebezpieczne dla rodowiska oraz dla ludzkiego zdrowia Urz dzenia u ywane lub zu yte mo na zda nieodp atnie w miejscu jego sprzeda y lub u dowolnego...

Reviews: