Before beginning assembly of the product, make sure all parts are present. Compare parts with
package contents list and hardware contents. If any part is missing or damaged, do not attempt
to assemble the product.
Estimated assembly time: 20 minutes.
Note: Fixture should be installed by persons with experience
in household wiring or by a qualified electrician. The
electrical system and the method of electrically connecting
this fixture to it must be in accordance with the National
Electrical Code and local building codes.
Install the motion sensor between 1.9 m / 6.2 ft and
3 m / 9.8 ft above the ground. Motion sensor is less
sensitive above 3 m / 9.8 ft.
Mount motion sensor so motion moves across detection
zone.
Mount sensor away from heat producing sources to
prevent false triggering. Also be very careful not to
include objects such as windows, white walls and water
in the detection zone.
Mount fixture away from moving objects such as trees
and street traffic.
Suitable for wall mounting or eave mounting.
MOUNTING LOCATIONS
Determine the mounting location – a Wall or Eave.
Make sure “This side UP” of sensor face up after
installation.
Position the lamp head in the general direction of the
desired light coverage.
If needed, adjust the motion sensor up and down so the
controls face the ground after installation.
Note: Do not mount this light fixture on the ground.
Important notes:
1. Environmental temperature affects the sensor range. It is recommended not to mount
the fixture near a heat source like an air conditioner, vent, or furnace exhaust, or in a
direction facing a light reflecting object.
2. The sensor will be more sensitive to motion across its detection path than motion coming
directly towards it.
3. For best performance, gently clean the lens with a soft cloth every two months to assure
maximum sensitivity.
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions
and other hazards read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing or performing routine maintenance upon this equipment, follow these general
precautions.
- If you are unsure about the installation or maintenance of this fixture, consult a qualified, licensed electrician.
o Do not mount the unit against flammable surfaces.
o The motion detector will not operate correctly if it is installed:
Near the outlet of a central heating boiler
Near an air conditioning unit
Pointing directly at moving vehicles
Within sight of reflection from moving water
Where other lamps could shine on the detector
- Fixtures can’t be used with a dimmer switch, motion or occupancy sensor and other electronic switching devices
unless otherwise designated. LED fixtures must be powered directly off a switch circuit.
- This fixture should not be used in areas with limited ventilation or high ambient temperatures.
- This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
- These instructions do not claim to cover all details or variations in equipment or provide every possible contingency
to meet in connection with the installation, operation or maintenance. Should further information be needed, you may
contact American Customer Service at 1-855-232-6427.
WARNING: RISK OF ELECTRICAL SHOCK
Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
Verify that the supply voltage is correct. Connect fixture to a 120 volt, 60 Hz power source.
Make sure all electrical and grounded connections are in accordance with the National Electrical Code and any
applicable local code requirements.
All wiring connections should be capped with UL listed wire connectors.
CAUTION: RISK OF PRODUCT DAMAGE
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
Never connect an LED product directly to dimmer packs, occupancy sensors, timing devices or other related control
device, unless individual product specifications deem otherwise.
Unless individual product deems otherwise: do not exceed fixtures maximum ambient temperatures.
LED products are Polarity Sensitive. Ensure proper polarity before installation.
Electrostatic Discharge (ESD) can cause damage to LED fixtures. Personal grounding equipment must be worn
during all installation or servicing of the unit.
Do not touch the individual electronic components, it may cause ESD, shorten lamp life or alter performance.
CAUTION: RISK OF INJURY
Wear gloves and safety glasses at all times when removing fixture from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on. LED LAMPS ARE EXTREMELY BRIGHT. UNDER NO
CIRCUMSTANCES SHOULD YOU STARE INTO AN LED BEAM, THIS MAY CAUSE IRREPARABLE DAMAGE
TO THE EYE.
Account for small parts and destroy packaging materials, as these may be hazardous to children.
WARNING: RISK OF BURN
Allow fixture to cool before handling. Do not touch enclosure of light source.
Do not exceed the maximum wattage marked on the label.
Keep combustible and other materials that can burn away from the luminaries, fixture and lamp/lens.
IMPORTANT SAFETY INSTRUCTIONS
PRE-INSTALLATION
!
!
!
!
Wall Mount
THIS SIDE
Eave Mount
Sensor detects motion that moves
across the detection zone
02
03