background image

2.  Adjusting the detector

    After installing your motion activated light, you are ready to set /aim the motion detector.

    Detection Range: around 21.3 m / 70 ft x 240 degrees ( Max ) 

    

21.3 m / 70 ft detection range based on ambient temperature 25 Celsius degree. 

-  Adjust the sensor head horizontal for long coverage.    

3. Manual Override Function

When power is on, the PIR sensor enters a “warm-up” period for 

about 40 seconds, then automatically switches into AUTO MODE.

During AUTO MODE, by switching the main switch OFF for about 

1 second then ON, the PIR sensor will automatically change into 

MANUAL MODE from AUTO MODE. In MANUAL MODE, the lights 

will remain ON, and will NOT be controlled by time duration or 

ambient light (LUX) levels. 

The MANUAL MODE will change to 

AUTO MODE in 6 hours automatically.

During MANUAL MODE, by switching the main switch OFF over 

30 seconds then back ON again, the PIR sensor will reset to the 

“warm-up” period.

Note: When you first install your security light, you must aim the detector head to cover

           the desired area.

Rotate the motion sensor so the controls face toward the ground. 

4. Blue LED sensor indicator

The Blue LED Light will flash to show that the PIR sensor is functioning properly.

- SENS Setting

Adjust the SENS setting to adjust range of Passive Infrared 

Motion Sensor

-  Slide the “ SENS” switch toward the “     ” (low) position for 

   short detection range. 

-  Slide the “ SENS” switch toward the “      ” (middle) position 

   for middle detection range. 

-  Slide the “ SENS” switch toward the “      ” (high) position for 

   long detection range.

-   LUX Setting

    This setting is used to control the ambient light level for the        

    motion security light to turn on after motion detection. 

   Slide the “LUX” switch toward the “     ” position to turn on in  

  daylight or in sunset or in darkness. 

  Slide the “LUX” switch toward the “     ” position to turn on in   

  sunset or in darkness.

  Slide the “LUX” switch toward the “    ” position to turn on in  

 darkness. 

-   TIME Setting

  This setting is used to control the time span of how long the  

  light remains on when motion is detected. 

  Set the “     ” switch to the 1, 3, 7 minutes position.  The         

  security light will stay on as long as motion is detected and  

  will go off after the time span you set  after no motion is    

 detected.

-   BRIGHT Setting

  This setting controls the brightness of light. 

  Slide the “      ” switch toward the “     ” position for high

  lumen output.

  Slide the “     ” switch toward the “     ” position for low lumen  

 output.

The higher the “ SENS” setting (sensitivity), the greater the possibility of false

triggering. To reduce false triggering,  slide the “SENS” switch toward the “       ” (low) 

setting if you don’t need long detection distance while using this light.

OPERATION (Continued)

OPERATION (Continued)

10º

20º

140º

180º

240º

21.3 m / 70 ft

2.5 m

/  8.2 ft

1 m /  3.2 ft

21.3 m /  70 ft

18 m / 59 ft
12 m / 39.3 ft

8 m / 26.2 ft

5 m / 16.4 ft

1 m / 3.2 ft

Turn the switch

OFF for 1 second

Turn the switch

back ON 

08

09

Summary of Contents for ES06553G

Page 1: ...mmunications However there is no guarantee that interference will not occur in a particular installation If the equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase th...

Page 2: ...dimmer switch motion or occupancy sensor and other electronic switching devices unless otherwise designated LED fixtures must be powered directly off a switch circuit This fixture should not be used in areas with limited ventilation or high ambient temperatures This fixture is intended to be connected to a properly installed and grounded UL listed junction box These instructions do not claim to co...

Page 3: ...en mounting to an eave the UP arrow must point toward the building Tools Required for Installation not included WARNING Risk of electric shock Disconnect power at fuse or circuit breaker before installing or servicing CAUTION Do not cut any wires with factory installed wire connectors or remove the wire connectors A Light Fixture 1 B Small mounting bolt 1 C Decorative Cover 1 D Mounting Plate 1 E ...

Page 4: ...nting bolt H securely through the center of the mounting plate D Do not overtighten Push the rubber plug C firmly into the large mounting bolt hole on the light fixture A Step 5 Caulking Around the Light Fixture Caulk around the canopy and mounting surface with silicone sealant not included 1 Adjusting the Lamp heads and Sensor Lamp heads can be adjusted easily You may adjust the lamp head left an...

Page 5: ...NS switch toward the low position for short detection range Slide the SENS switch toward the middle position for middle detection range Slide the SENS switch toward the high position for long detection range LUX Setting This setting is used to control the ambient light level for the motion security light to turn on after motion detection Slide the LUX switch toward the position to turn on in dayli...

Page 6: ...VAC 60Hz 37W 5 Load Rating No extra lights should be added to this unit 1 Energy saving much lower power consumption and savings 2 Longer lifetime Solid State lighting has no filament to break 3 Light does not radiate heat To prolong the original appearance clean with clear water and a soft damp cloth only Do not use paints solvents or other chemicals on this light fixture They could cause a prema...