2. Safety Warnings 

2.1. General Instructions 
Signs used to mark instructions in this manual 

Safety instructions in these operating instructions, which, 

if not observed, could cause a danger for persons are 
marked with the general symbol in accordance with DIN 
4844-W 9. 

Warnings against electrical voltage are marked with the 

safety symbol in accordance with DIN 4844-W 8. 
 

2.2. General Safety Precautions

 

General regulations and guidelines not mentioned in the  

safety warnings retain their validity. 

These operating instructions contain basic instructions, 

which have to be adhered to during installation, operation 
and maintenance. These operating instructions must be read 
from mechanic and the operator before installation and op-
eration of the pump and have to be kept available at the 
operating place of the machine/unit at all times. Persons who 
are not familiar with the operating instructions shall not use 
this product. 

Children and adolescents under age 16 shall not use the 
pump and must keep away from the machine/unit  
while it is operational.

 

If you have to work with welding tools or electric tools, 

make sure that there is no explosion hazard. 

Immediately after repair or maintenance work, all safety 

and protection equipment must be reinstalled and placed in 
function again. 

The operator of the pump is responsible for third parties 

within the work area. 

Persons are not permitted to stay in the pumping me-

dium during operation of the pump. 

All other rules and regulations and local codes covering 

health and safety must be observed. In accordance with 
product liability law, we point out that we shall not be liable for 
damages caused by the pump due to non-observance of the 
instructions and guidelines set forth in the operating instruc-
tions. The same product liability are valid for accessories. 
 

3. Applications and Technical Description 

3.1. Applications 

Waste water submersible pumps must be fully submerged in 
the pumped medium. TCV pumps are designed for pumping 
dirty water like rain water or ground water with solid sizes: 
 

Pump type                  Max. dia. solids 

TCV 

408          35 

mm      

 
The pumps are used for pumping water from basements, 
cellars or surface water from sumps. 
The pumps must not be used for pumping of liquids contain-
ing great quantities of abrasive solids, like sand or stones. 
Before the pumping of chemically aggressive liquids, the 
resistance of the pump materials must be checked. 

If the pump is used for cleaning or maintenance of 

swimming pools, make sure that no persons stay in the 
swimming pool during operation of the pump and that the 
pump is self-assured by a 30 mA earth leakage circuit  
breaker. 

The voltage required in the technical data sheet 

must correspond to the existing line voltage. 

3.2. Technical Data

 

Voltage 

230 V / 50 Hz / 1 ph 

Speed 2900 

rpm 

Insulation class 

Motor protection 

IP 68 

Max. liquid temperature 

35°C (short term up to 60°C) 

Motor input 

1000 Watt 

Input current 

4,8 A 

Max. head 

11 m 

Max. flow 

20.400 l/h 

Discharge size 

BSP 1 ½“ F 

Weight 8,2 

kg 

 

4. Warranty 

Our warranty only covers pumps which are installed and 
operated in accordance with these installation and operation 
instructions and accepted codes of good practice and being 
used for the applications mentioned in these instructions. 

 

5. Transport and Storage 

Never use the cable or the discharge hose/pipe to lift, 

lower, transport or attach the pump. Always use the handle or 
a rope or a chain attached to the handle. 

The pump may be transported and stored in vertical or 

horizontal position. Make sure that it cannot roll or fall over. 
For longer periods of storage, the pump should be protected 
against moisture, frost or heat. 
 

6. Electrical Connection 

Before operation, an expert check must secure that the 

required electrical protection measures exist. The connection 
to ground, earthing, isolating transformer, fault current 
breaker or fault voltags circuit must correspond to the guide-
lines set forth by the responsible power plant. 

The voltage required in the technical data sheet 

must correspond to the existing line voltage. 

Submersible pumps used outside of buildings must  

have a cable with a minimum length of 10m. 

Make sure that the electrical pin-and-socket connections 

are installed flood- and moisture-safe. Before starting opera-
tion check the cable and the plug against damages. 

The end of the pump power supply cable must not be 

submerged in order to prevent water from penetrating 
through the cable into the motor. 

The normal separate motor starter/control box of stan-

dard as well as of explosion proof pumps must not be in-
stalled in explosive enviroments.

 

 

7. Installation 

7.1. Submerged Base Stand Installation

 

The pump may be installed with a flexible discharge hose or 
a rigid pipe, non-return valve and isolating valve. If a flexible 
hose is used, make sure that the hose has the same diame-
ter like the pump discharge and does not buckle. 
For an optimally performance the discharge pipe should have 
a minimum diameter of 1 ¼“. Gate valves and non-return-
valves have to be installed in accordance to the local rules 
and regulations.  
Fix a rope or a chain to the pump handle and lower the pump 
into the liquid. If the pump is installed on muddy ground, 
support it on bricks to prevent it from sinking in. 

Summary of Contents for TCV 408 Series

Page 1: ...Original Betriebsanleitung Original Instruction Manual HOMA Pumpenfabrik GmbH 02 2011 Industriestr 1 D 53819 Neunkirchen Seelscheid Baureihe Series TCV 408 W A...

Page 2: ...2 Inhalt Contents Seite 3 Page 8 Seite 12 Page 12 Seite 12 Page 12 DEUTSCH ENGLISH Bauma e Dimensions Ersatzteilliste und Ersatzteilzeichnungen Spare part list and spare part drawings...

Page 3: ...en der EG Maschinenrichtlinien entsprechen Bei einer nicht mit uns abgestimmten nderung der Pumpen verliert diese Erkl rung Ihre G ltigkeit EG Richtlinien denen die Pumpen entsprechen EG Maschinenrich...

Page 4: ...Sammelbecken als Notpumpe bei berflutungen usw Schmirgelnde oder andere werkstoffangreifende Stoffe k nnen die Pumpe zerst ren Die Pumpen sind nicht geeignet f r den Dauereinsatz in F rdermedien mit...

Page 5: ...rch einen Probelauf zu kontrollieren M gliche Folgen bei Nichtbeachtung sind berflutung Pumpe schaltet nicht ein bzw Zerst rung der Pumpe durch Trockenlauf Pumpe schaltet nicht ab Maximale Eintauchtie...

Page 6: ...frad blockiert Saugsieb abschrau ben und Laufrad rei nigen Temperatur des F rdermediums ist zu hoch Die Temperatur des F rdermediums darf maximal 35 C betra gen Keine ausreichende K hlung des Motors z...

Page 7: ...ingen 03 31 740 40 70 0 74 31 95 83 24 Naumann Pumpen GmbH Co KG G Meier GmbH Am Wall 11 Gustav Schwab Str 16 14979 Gro beeren 72762 Reutlingen 03 37 01 52 50 0 71 21 26 90 0 HEKO Pumpen GmbH Pumpen Z...

Page 8: ...he relevant fundamental safety and health requirements of the EC Machine Directives TCV 408 EC Directives to which the pumps conform EC Machinery Directive 2006 42 EEC EC Directive electromagnetic com...

Page 9: ...swimming pool during operation of the pump and that the pump is self assured by a 30 mA earth leakage circuit breaker The voltage required in the technical data sheet must correspond to the existing l...

Page 10: ...f period as it will destroy the pump danger of overheating 9 Maintenance and Repair In case of a defect of the pump a repair shall be carried out only by the manufacturer or through an authorized work...

Page 11: ...rips out at high motor temperature in order to prevent overheating After re cooling the sensor switches on again automatically WEEE Notice The Directive on Waste Electrical and Electronic Equipment WE...

Page 12: ...12 12 Bauma e Dimension in mm 13 Ersatzteilliste und Zeichnungen 13 Spare part list and drawings 13 1 Ersatzteilzeichnung Spare Part Drawing TCV408W TCV408WA...

Page 13: ...g 34 Rotor mit Welle 35 Passfeder 36 Scheibe 37 Dichtung 38 Stator mit Wicklung 39 Gleitringdichtung 40 Laufrad 41 Scheibe 42 Sicherungsring 43 Mutter 44 O Ring 45 Druckring 46 Schlauchanschluss 47 Di...

Page 14: ...Key 36 Adjusting washer 37 Framework seal 38 Motor stator 39 Mechanical seal 40 Impeller 41 Plain cushion 42 Spring pad 43 Hexangular nut 44 O ring 45 Pressure ring 46 Connector 47 Gasket 48 O Ring 4...

Page 15: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 14 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Ye...

Page 16: ...xisch nein ja welche Stoffe _____________________ tzend nein ja welche Stoffe _____________________ mikrobiologisch nein ja welche Stoffe _____________________ explosiv nein ja welche Stoffe _________...

Page 17: ...______________ corrosive no yes which substance __________________ microbiological no yes which substance __________________ explosive no yes which substance __________________ radioactive no yes whic...

Page 18: ...____________ _______________________________ _______________________________ _______________________________ _______________________________ _______________________________ ___________________________...

Page 19: ...17...

Page 20: ...18...

Reviews: