Homa CH235 Instruction Manual Download Page 27

EngliSH | 27

sleeve (Item 827.02) must be pulled in or out a bit more 
(longer cable end = larger operating distance). The position 
of the anti-kink sleeve (Item 827.02) must not be changed. 
The distance between the anti-kink sleeve (Item 827.02) 
and the float (Item 838.45) must be at least 10 cm.

838.45

827.02

732

Float switch for intermediate coupling

Pumps without float switch can be retrofitted with a 
HOMA float switch for intermediate coupling. The elec-
trical connection is done by the intermediate coupling of 
the float switch between the outlet and the plug of the 
pump. With retrofitted installation, attach the float cable 
onto the pump or riser tube or on any other permanently 
installed point according to the desired switching distance 
and level. Never throw the float with cable into the me-
dium, since the correct switching is only possible with a 
rotary movement of the float around the mounting point 
of the cable. Possible consequences of non-compliance 
are flooding (pump does not turn on), or destruction of the 
pump by running dry (pump does not stop).

Important:

 After each change of the float mounting, it is 

necessary to check the proper function of the float switch 
by performing a trial run. When using separate floats for 
pump start, pump stop and the alarm set points (see 
Chapter 7.2 Paragraph Reference) must be chosen as 
above. The alarm float should turn about 10 cm above the 
pump switch-on, but always below the inlet.

5.3. Start-Up

This chapter contains all important instructions for the 
operator to ensure safe commissioning and operation of 
the machine. The following information must be strictly 
observed and reviewed:

• 

Type of installation

• 

Operating mode

• 

Minimum submergence/maximum immersion depth

After an extended down time, this data must be 
also checked and any detected deficiencies must be 
rectified! The operation and maintenance manual 
must always be close to the machine, or be kept in a  

designated place where all operators can access it at 
all times.

To avoid damage to persons or property during operation 
of the machine, the following points must be observed:

The commissioning of the machine must be carried 
out only by qualified and trained personnel in accor-
dance with the safety instructions.

• 

The entire staff working with the machine must re-
ceive, read and understand the operating instructions.

• 

Check all safety devices and emergency stops before 
commissioning.

• 

Electrical and mechanical adjustments may only be 
performed only by qualified employees.

• 

This machine is only suitable for the use of the  
specified operating conditions.

5.4. Preparatory Work

The machine has been designed and mounted according 
to state of the art, so that under normal operating con-
ditions it operates reliably and has a long operating life. 
However, this requires compliance with all requirements 
and instructions. During delivery, small oil leakages of the 
mechanical seal are acceptable, but must be removed 
before lowering or immersion it into the medium to be 
pumped.

Please check the following points:

• 

Cable routing - no loops, with some slack

• 

Check temperature of the medium and immersion 
depth - see machine data sheet

• 

If a hose is used on the pressure side, it must be 
flushed with clean water before use to ensure that 
deposits will not cause blockages

• 

With wet well installation, the sump pit must be 
cleaned.

• 

The pressure and suction piping must be cleaned and 
all slides must be opened.

• 

The pump housing must be flooded, i.e. it must be 
completely filled with the medium and no air should 
be inside. The bleeding can be done by appropriate 
venting devices in the system or, if available, by vent-
ing screws at the discharge nozzle.

• 

Check accessories, piping, hanging device for tight 
and correct fit

• 

Inspect existing level controls or dry run protector

5.5. Electrical 

When laying and selecting electrical cables and when con-
necting the motor, the relevant local and VDE regulations 
must be observed.

Danger from electric current!

Improper use of electricity may result in death! All 

pumps with bare cable ends must be connected by a 

qualified electrician.

Summary of Contents for CH235

Page 1: ...Original Betriebsanleitung EN Original Instruction Manual FR Manuel d instructions original NL Originele handleiding CH235 CH291...

Page 2: ...g 09 3 1 Verwendung 09 3 2 Einsatzarten 09 3 3 Aufbau 09 4 Verpackung Transport und Lagerung 11 4 1 Anlieferung 11 4 2 Transport 11 4 3 Lagerung 11 4 4 R cklieferung 11 5 Aufstellung und Inbetriebnahm...

Page 3: ...Unfallschutz und zur Unfallverh tung Diese Betriebsanleitung muss dem Bedienpersonal jederzeit am Einsatzort des Produk tes verf gbar sein 1 3 Bestimmungsgem e Verwendung Die HOMA Produkte entsprechen...

Page 4: ...5 2 Ersatzteile An und Umbauten Es d rfen nur Originalersatzteile des Herstellers f r Reparatur Austausch sowie An und Umbauten verwen det werden Nur diese garantieren h chste Lebensdauer und Sicherh...

Page 5: ...hnik Hainicher Str 37 Alsstra e 158 Wei erlenstr 1G 09569 Oederan 41063 M nchengladbach 79108 Freibung Hochdorf 03 72 92 50 00 02161 15308 07 61 13 09 70 Glaubrecht Pumpenservice GmbH Eugen Boss GmbH...

Page 6: ...Betriebsmittel kann pausenlos unter Nennlast arbei ten ohne dass die zul ssige Temperatur berschritten wird Betriebsart S2 Kurzzeitbetrieb Die Betriebsdauer wird in Minuten angegeben z B S2 20min Das...

Page 7: ...llstand gekommen sein Der Bediener hat jede auftretende St rung oder Unregelm igkeit sofort seinem Verantwortlichen zu melden Eine sofortige Stillsetzung durch den Bediener ist zwingend erforderlich w...

Page 8: ...die Maschine abschalten und die drehenden Teile zum Stillstand kommen lassen 2 7 Sicherheits und berwachungseinrichtungen Unsere Anlagen sind mit verschiedenen Sicherheits und berwachungseinrichtunge...

Page 9: ...ver wendeten Pumpenwerkstoffe zu beachten Die Pumpen sind sowohl f r den transportablen als auch f r den statio n ren Betrieb geeignet Die Installation ist freistehend auf festem Untergrund m glich D...

Page 10: ...aut intern im Motor ges chaltet so dass kein besonderer Anschluss notwendig ist Nach Abk hlung schaltet der Motor automatisch wieder ein Drehrichtungskontrolle Alle Pumpen haben die richtige Drehricht...

Page 11: ...bkni cken Besch digungen und Feuchtigkeitseintritt zu sch tzen Gefahr durch elektrischen Strom Durch besch digte Stromzuf hrungsleitungen droht Lebensgefahr Defekte Leitungen m ssen sofort vom qualifi...

Page 12: ...ine Undichtigkeit die F rderleistung der Pumpe vermindert Die Pumpe am Haltegriff mit Seil oder Kette befestigen und daran ins F rdermedium herunterlassen Bei schlam migem Untergrund Steine o unter di...

Page 13: ...Sicherheitseinrichtungen und Not Aus Schaltungen vor der Inbetriebnahme Elektrotechnische und mechanische Einstellungen d rfen nur von Fachkr ften ausgef hrt werden Diese Maschine ist nur f r den Eins...

Page 14: ...nigungsar beiten an der Maschine und der Anlage m ssen mit gr ter Sorgfalt an einem sicheren Arbeitsplatz und von geschultem Fachpersonal durchgef hrt werden Es m ssen die n tigen K rperschutzmittel g...

Page 15: ...M6 7 Nm 11 8 Nm M8 17 Nm 28 7 Nm M10 33 Nm 58 Nm M12 57 Nm 100 Nm M16 140 Nm 245 Nm M20 273 Nm 494 Nm 7 2 Wechsel von verschiedenen Pumpenteilen Laufrad und Pumpengeh use wechseln Die Zylinderschraub...

Page 16: ...ig halbj hrlich von Hand zu drehen Dies verhindert Eindr ckmarken in den Lagern und ein festsetzen des L ufers 8 3 Wiederinbetriebnahme nach l ngerer Einlage rung Die Maschine muss vor Wiederinbetrie...

Page 17: ...chen Pumpe saugt sich am flexiblem Boden fest Stellen sie die Pumpe auf einen festen Untergrund Maschine l uft die angegebenen Betriebswerte werden nicht eingehalten Ursache Abhilfe Zulauf verstopft Z...

Page 18: ...se 23 3 2 Type of application 23 3 3 Construction 23 4 Package Transport Storage 25 4 1 Delivery 25 4 2 Transport 25 4 3 Storage 25 4 4 Returning to the supplier 26 5 Installation and Start Up 26 5 1...

Page 19: ...e to personnel at all times and also be made available where the product is used 1 3 Proper use The HOMA products comply with the valid safety regu lations and meet the demands of state of the art tec...

Page 20: ...nufactur er may be used for repairs replacements add ons and conversions Only these parts guarantee a long working life and the highest level of safety These parts have been specially designed for our...

Page 21: ...stalling a float switch Level control The level control is designed to switch the product on or off depending on the filling level This is made possible by installing a float switch 2 Safety This chap...

Page 22: ...out by a qualified electrician Beware of damp Moisture penetrating cables can damage them and render them useless Furthermore water can pen etrate into the terminal compartment or motor and cause dam...

Page 23: ...ve fluids It is absolutely prohibited to pump explosive liquids e g gasoline kerosene etc The products are not designed for these liquids 2 9 Sound Pressure Depending on the size and power kW the pump...

Page 24: ...5 Operating mode S3 Medium temperature 35 C for short periods up to 60 C Insulation class F Protection type IP68 Cable length CH W D 5 m Cable length CH WA DA 10 m Voltage CH W 230V 1Ph 50Hz Voltage C...

Page 25: ...and secure it against falling over Submersible mixers and auxiliary lifting devices should be stored horizontally submer sible sewage pumps and submersible motor pumps should be stored horizontally o...

Page 26: ...st be attached on the pressure socket of the pump and attach the pressure line When using a tube or pipe fitting with thread the hose nozzle can be cut on the hose connection of the pump In order to e...

Page 27: ...ere all operators can access it at all times To avoid damage to persons or property during operation of the machine the following points must be observed The commissioning of the machine must be carri...

Page 28: ...tions of use The manufac turer must be contacted in the event of aggressive and or abrasive pumped mediums since the interval could be shortened in these cases The following points must be noted The o...

Page 29: ...tated are for clean lubricated screws Fixing torque Nm for screws A2 A4 Coefficient of friction 0 2 A2 A4 Hardeness class 70 A2 A4 Hardeness class 80 DIN912 DIN933 DIN912 DIN933 M6 7 Nm 11 8 Nm M8 17...

Page 30: ...e elastomers of the seals During lengthy periods of storage regularly for ex ample every six months turn the impeller or propeller by hand This prevents indentations in the bearings and stops the roto...

Page 31: ...exible ground Move the pump on hard ground The machinery is running the indicated operating values are not met Cause Remedy Inlet obstructed Clean inlet gate valve suction piece suction branch suction...

Page 32: ...ingswijzen 38 3 3 Opbouw 38 4 Verpakking transport en opslag 40 4 1 Aanlevering 40 4 2 Transport 40 4 3 Opslag 40 4 4 Retourneren 40 5 Opstelling en inbedrijfstelling 41 5 1 Algemeen 41 5 2 Installati...

Page 33: ...tie en of breidt deze uit Deze handleiding moet altijd beschikbaar zijn voor het be dieningspersoneel op de werkplek van het product 1 3 Beoogd gebruik De HOMA producten voldoen aan de geldende veilig...

Page 34: ...e afspraken lopen ten minste tot aan het overeengekomen einde van de wettelijke garanti etermijn van het product 1 5 2 Onderdelen aan en ombouwwerkzaamheden Er mogen uitsluitend originele onderdelen v...

Page 35: ...g wordt een gelijkblijvende tem peratuur bereikt die ook bij langer bedrijf niet meer stijgt Het materieel kan ononderbroken onder nominale belast ing werken zonder dat de toegestane temperatuur wordt...

Page 36: ...nggevende Een onmiddellijke stilzetting door de bediener is dwin gend noodzakelijk wanneer er gebreken optreden die de veiligheid in gevaar brengen Hieronder vallen Falen van de veiligheids en of bewa...

Page 37: ...ids en bewakingscontroles Deze inrichtingen mogen niet worden gedemonteerd of uitgeschakeld Inrichtingen moeten v r de inbedrijfstelling door een elektricien aang esloten en op correcte werking gecon...

Page 38: ...10 minuten 3 3 Opbouw Het volledig overstroombare aggregaat bestaat uit de mo tor het pomphuis en de juiste waaier Alle belangrijke on derdelen zijn ruim bemeten Nr beschrijving 1 motorhuis 2 persaans...

Page 39: ...on trole plaatsvinden door de start schok te observeren Hier toe de pomp verticaal iets op de rand op de grond zetten en kort inschakelen Van bovenaf gezien schokt de pomp bij de juiste draairichting...

Page 40: ...mineerd De verpakking moet het product beschermen tegen beschadigingen Raadpleeg de fabrikant voorafgaand aan het retourneren 4 Verpakking transport en opslag 4 1 Aanlevering Na ontvangst moet de zend...

Page 41: ...mdat een ondichtheid de pompcapaciteit van de pomp vermindert De pomp met kabel of ketting aan de handgreep bevesti gen en daaraan in de vloeistof laten zakken Bij modderige ondergrond stenen o i d on...

Page 42: ...eidsinrichtingen en noodstop schakelingen v r de inbedrijfstelling Elektrotechnische en mechanische instellingen mo gen alleen door vakkrachten worden uitgevoerd Deze machine is alleen geschikt voor t...

Page 43: ...rden af gevoerd volgens richtlijn 75 439 EEG en verordenin gen 5a 5b volgens AbfallGesetz Duitse afvalwet Bij reinigings en onderhoudswerkzaamheden moet de juiste beschermende kleding worden gedragen...

Page 44: ...ngen Schroefborgingen zoals veerringen moeten altijd worden vervangen De aanhaalmomenten moeten worden aangehoud en Algemeen geldt bij reparatiewerkzaamheden Machine uitschakelen loskoppelen van het s...

Page 45: ...en en werkzaamheden worden uitgevoerd zie hoofdstuk On derhoud De correcte toestand en de werking van de gli jringafdichting moet worden gecontroleerd Na afronding van deze werkzaamheden kan de machin...

Page 46: ...zich aan flexibele bodem vast Plaats de pomp op een stevige vlakke ondergrond Machine draait maar de opgegeven bedrijfswaarden worden niet aangehouden Oorzaak Oplossing Toevoer verstopt Toevoerleidin...

Page 47: ...Nedlerlands 47 Notizen Notes...

Page 48: ...dingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sonsti...

Page 49: ...the instruments toxic no yes substance corrosive no yes substance microbiological no yes substance explosive no yes substance radioactive no yes substance other substances no yes substance Legally bin...

Page 50: ...tourneren Contaminatie van het apparaat als gevolg van de toepassing giftig nee ja welke stoffen bijtend nee ja welke stoffen microbiologisch nee ja welke stoffen explosief nee ja welke stoffen radioa...

Page 51: ...our other household waste You are liable to dispose of all your electronic or electrical waste equipment by relocating over to the specified collection point for recycling of such hazardous waste Isol...

Page 52: ...x 49 0 2247 702 44 e Mail info homa pumpen de Internet www homa pumpen de Industriestra e 1 53819 Neunkirchen Seelscheid Telefon 49 0 2247 702 0 Fax 49 0 2247 702 44 e Mail info homa pumpen de Interne...

Reviews: