Homa CH235 Instruction Manual Download Page 22

22 | EngliSH

• 

It is of vital importance that the system is shut down 
immediately by the operator if any problems arise 
which may endanger safety of personnel. Problems 
of this kind include: 

• 

Failure of the safety and/or control devices

• 

Damage to critical parts

• 

Damage to electric installations, cables and 

 

insulation.

• 

Tools and other objects should be kept in a place re-
served for them so that they can be found quickly.

• 

Sufficient ventilation must be provided in enclosed 
rooms.

• 

When welding or working with electronic devices, 
ensure that there is no danger of explosion.

• 

To prevent suffocation and poisoning caused by ven-
omous gases, make sure that enough oxygen exists 
at the workplace.

• 

Immediately after repair or maintenance work, all 
safety and protection equipment must be reinstalled 
and placed in function again.

• 

All other rules and regulations and local codes cov-
ering health and safety must be observed. In accor-
dance with product liability law, we point out that we 
shall not be liable for damages caused by the pump 
due to non-observance of the instructions and guide-
lines set forth in the operating instructions. The same 
product liability are valid for accessories.

These instructions must be strictly observed. 

Non-observance can result in injury or serious 

 

damage to property.

2.4. Operating personal

All personnel who work on or with the product must be 
qualified for such work; electrical work, for example may 
only be carried out by a qualified electrician. The entire 
personnel must be of age.
Operating and maintenance personnel must also work ac-
cording to local accident prevention regulations.
It must be ensured that personnel have read and under-
stood the instructions in this operating and maintenance 
handbook; if necessary this manual must be ordered from 
the manufacturer in the required language.

2.5. Electrical work

Our electrical products are operated with single-phase or 
three-phase-current. The local regulations (e.g. VDE 0100) 
must be adhered to. The “Electrical connection” data 
sheet must be observed when connecting the product. 
The technical specifications must be strictly adhered to. If 
the machine has been switched off by a protective device, 
it must not be switched on again until the error has been 
corrected.

Beware of electrical current!

Incorrectly performed electrical work can result in 

fatal injury! This work may only be carried out by a 

qualified electrician.

Beware of damp!

Moisture penetrating cables can damage them and 

render them useless. Furthermore, water can pen-

etrate into the terminal compartment or motor and 

cause damage to the terminals or the winding. Nev-

er immerse cable ends in the pumped fluid or other 

liquids.

2.5.1. Electrical connection

When the machine is connected to the electrical control 
panel, especially when electronic devices such as soft 
startup control or frequency drives are used, the relay 
manufacturer‘s specifications must be followed in order 
to conform to EMC. Special separate shielding measures 
e.g. special cables may be necessary for the power supply 
and control cables.

The connections may only be made if the relays meet the 
harmonized EU standards. Mobile radio equipment may 
cause malfunctions.

2.5.2. Ground connection

Our products (machine including protective devices and 
operating position, auxiliary hoisting gear) must always be 
grounded. If there is a possibility that people can come 
into contact with the machine and the pumped liquid (e.g. 
at construction sites), the grounded connection must be 
additionally equipped with a fault current protection de-
vice. The electrical motors conform to motor protection 
class IP 68 in accordance with the valid norms.

2.6. Operating procedure

When operating the product, always follow the locally 
applicable laws and regulations for work safety, accident 
prevention and handling electrical machinery. To help to 
ensure safe working practice, the responsibilities of em-
ployees should be clearly set out by the owner. All per-
sonnel are responsible for ensuring that regulations are 
observed. Certain parts such as the rotor and propeller 
rotate during operation in order to pump the fluid. Certain 
materials can cause very sharp edges on these parts.

Beware of rotating parts!

The moving parts can crush and sever limbs. Never 

reach into the pump unit or the moving parts during 

operation. Switch off the machine and let the moving 

parts come to a rest before maintenance or repair 

work!

2.7. Safety and control devices

Our products are equipped with various safety and con-
trol devices. These devices must never be dismantled or 
disabled. Equipment must be checked by an electrician 
for proper functioning before start-up (see the “Electrical 
Connection” data sheet). Please remember that certain 
equipment requires a decoder device or relay to function 
properly. 
This decoder can be obtained from the manufacturer or a 
specialist electronics dealer.
Personnel must be informed of the installations used and 
how they work.

Summary of Contents for CH235

Page 1: ...Original Betriebsanleitung EN Original Instruction Manual FR Manuel d instructions original NL Originele handleiding CH235 CH291...

Page 2: ...g 09 3 1 Verwendung 09 3 2 Einsatzarten 09 3 3 Aufbau 09 4 Verpackung Transport und Lagerung 11 4 1 Anlieferung 11 4 2 Transport 11 4 3 Lagerung 11 4 4 R cklieferung 11 5 Aufstellung und Inbetriebnahm...

Page 3: ...Unfallschutz und zur Unfallverh tung Diese Betriebsanleitung muss dem Bedienpersonal jederzeit am Einsatzort des Produk tes verf gbar sein 1 3 Bestimmungsgem e Verwendung Die HOMA Produkte entsprechen...

Page 4: ...5 2 Ersatzteile An und Umbauten Es d rfen nur Originalersatzteile des Herstellers f r Reparatur Austausch sowie An und Umbauten verwen det werden Nur diese garantieren h chste Lebensdauer und Sicherh...

Page 5: ...hnik Hainicher Str 37 Alsstra e 158 Wei erlenstr 1G 09569 Oederan 41063 M nchengladbach 79108 Freibung Hochdorf 03 72 92 50 00 02161 15308 07 61 13 09 70 Glaubrecht Pumpenservice GmbH Eugen Boss GmbH...

Page 6: ...Betriebsmittel kann pausenlos unter Nennlast arbei ten ohne dass die zul ssige Temperatur berschritten wird Betriebsart S2 Kurzzeitbetrieb Die Betriebsdauer wird in Minuten angegeben z B S2 20min Das...

Page 7: ...llstand gekommen sein Der Bediener hat jede auftretende St rung oder Unregelm igkeit sofort seinem Verantwortlichen zu melden Eine sofortige Stillsetzung durch den Bediener ist zwingend erforderlich w...

Page 8: ...die Maschine abschalten und die drehenden Teile zum Stillstand kommen lassen 2 7 Sicherheits und berwachungseinrichtungen Unsere Anlagen sind mit verschiedenen Sicherheits und berwachungseinrichtunge...

Page 9: ...ver wendeten Pumpenwerkstoffe zu beachten Die Pumpen sind sowohl f r den transportablen als auch f r den statio n ren Betrieb geeignet Die Installation ist freistehend auf festem Untergrund m glich D...

Page 10: ...aut intern im Motor ges chaltet so dass kein besonderer Anschluss notwendig ist Nach Abk hlung schaltet der Motor automatisch wieder ein Drehrichtungskontrolle Alle Pumpen haben die richtige Drehricht...

Page 11: ...bkni cken Besch digungen und Feuchtigkeitseintritt zu sch tzen Gefahr durch elektrischen Strom Durch besch digte Stromzuf hrungsleitungen droht Lebensgefahr Defekte Leitungen m ssen sofort vom qualifi...

Page 12: ...ine Undichtigkeit die F rderleistung der Pumpe vermindert Die Pumpe am Haltegriff mit Seil oder Kette befestigen und daran ins F rdermedium herunterlassen Bei schlam migem Untergrund Steine o unter di...

Page 13: ...Sicherheitseinrichtungen und Not Aus Schaltungen vor der Inbetriebnahme Elektrotechnische und mechanische Einstellungen d rfen nur von Fachkr ften ausgef hrt werden Diese Maschine ist nur f r den Eins...

Page 14: ...nigungsar beiten an der Maschine und der Anlage m ssen mit gr ter Sorgfalt an einem sicheren Arbeitsplatz und von geschultem Fachpersonal durchgef hrt werden Es m ssen die n tigen K rperschutzmittel g...

Page 15: ...M6 7 Nm 11 8 Nm M8 17 Nm 28 7 Nm M10 33 Nm 58 Nm M12 57 Nm 100 Nm M16 140 Nm 245 Nm M20 273 Nm 494 Nm 7 2 Wechsel von verschiedenen Pumpenteilen Laufrad und Pumpengeh use wechseln Die Zylinderschraub...

Page 16: ...ig halbj hrlich von Hand zu drehen Dies verhindert Eindr ckmarken in den Lagern und ein festsetzen des L ufers 8 3 Wiederinbetriebnahme nach l ngerer Einlage rung Die Maschine muss vor Wiederinbetrie...

Page 17: ...chen Pumpe saugt sich am flexiblem Boden fest Stellen sie die Pumpe auf einen festen Untergrund Maschine l uft die angegebenen Betriebswerte werden nicht eingehalten Ursache Abhilfe Zulauf verstopft Z...

Page 18: ...se 23 3 2 Type of application 23 3 3 Construction 23 4 Package Transport Storage 25 4 1 Delivery 25 4 2 Transport 25 4 3 Storage 25 4 4 Returning to the supplier 26 5 Installation and Start Up 26 5 1...

Page 19: ...e to personnel at all times and also be made available where the product is used 1 3 Proper use The HOMA products comply with the valid safety regu lations and meet the demands of state of the art tec...

Page 20: ...nufactur er may be used for repairs replacements add ons and conversions Only these parts guarantee a long working life and the highest level of safety These parts have been specially designed for our...

Page 21: ...stalling a float switch Level control The level control is designed to switch the product on or off depending on the filling level This is made possible by installing a float switch 2 Safety This chap...

Page 22: ...out by a qualified electrician Beware of damp Moisture penetrating cables can damage them and render them useless Furthermore water can pen etrate into the terminal compartment or motor and cause dam...

Page 23: ...ve fluids It is absolutely prohibited to pump explosive liquids e g gasoline kerosene etc The products are not designed for these liquids 2 9 Sound Pressure Depending on the size and power kW the pump...

Page 24: ...5 Operating mode S3 Medium temperature 35 C for short periods up to 60 C Insulation class F Protection type IP68 Cable length CH W D 5 m Cable length CH WA DA 10 m Voltage CH W 230V 1Ph 50Hz Voltage C...

Page 25: ...and secure it against falling over Submersible mixers and auxiliary lifting devices should be stored horizontally submer sible sewage pumps and submersible motor pumps should be stored horizontally o...

Page 26: ...st be attached on the pressure socket of the pump and attach the pressure line When using a tube or pipe fitting with thread the hose nozzle can be cut on the hose connection of the pump In order to e...

Page 27: ...ere all operators can access it at all times To avoid damage to persons or property during operation of the machine the following points must be observed The commissioning of the machine must be carri...

Page 28: ...tions of use The manufac turer must be contacted in the event of aggressive and or abrasive pumped mediums since the interval could be shortened in these cases The following points must be noted The o...

Page 29: ...tated are for clean lubricated screws Fixing torque Nm for screws A2 A4 Coefficient of friction 0 2 A2 A4 Hardeness class 70 A2 A4 Hardeness class 80 DIN912 DIN933 DIN912 DIN933 M6 7 Nm 11 8 Nm M8 17...

Page 30: ...e elastomers of the seals During lengthy periods of storage regularly for ex ample every six months turn the impeller or propeller by hand This prevents indentations in the bearings and stops the roto...

Page 31: ...exible ground Move the pump on hard ground The machinery is running the indicated operating values are not met Cause Remedy Inlet obstructed Clean inlet gate valve suction piece suction branch suction...

Page 32: ...ingswijzen 38 3 3 Opbouw 38 4 Verpakking transport en opslag 40 4 1 Aanlevering 40 4 2 Transport 40 4 3 Opslag 40 4 4 Retourneren 40 5 Opstelling en inbedrijfstelling 41 5 1 Algemeen 41 5 2 Installati...

Page 33: ...tie en of breidt deze uit Deze handleiding moet altijd beschikbaar zijn voor het be dieningspersoneel op de werkplek van het product 1 3 Beoogd gebruik De HOMA producten voldoen aan de geldende veilig...

Page 34: ...e afspraken lopen ten minste tot aan het overeengekomen einde van de wettelijke garanti etermijn van het product 1 5 2 Onderdelen aan en ombouwwerkzaamheden Er mogen uitsluitend originele onderdelen v...

Page 35: ...g wordt een gelijkblijvende tem peratuur bereikt die ook bij langer bedrijf niet meer stijgt Het materieel kan ononderbroken onder nominale belast ing werken zonder dat de toegestane temperatuur wordt...

Page 36: ...nggevende Een onmiddellijke stilzetting door de bediener is dwin gend noodzakelijk wanneer er gebreken optreden die de veiligheid in gevaar brengen Hieronder vallen Falen van de veiligheids en of bewa...

Page 37: ...ids en bewakingscontroles Deze inrichtingen mogen niet worden gedemonteerd of uitgeschakeld Inrichtingen moeten v r de inbedrijfstelling door een elektricien aang esloten en op correcte werking gecon...

Page 38: ...10 minuten 3 3 Opbouw Het volledig overstroombare aggregaat bestaat uit de mo tor het pomphuis en de juiste waaier Alle belangrijke on derdelen zijn ruim bemeten Nr beschrijving 1 motorhuis 2 persaans...

Page 39: ...on trole plaatsvinden door de start schok te observeren Hier toe de pomp verticaal iets op de rand op de grond zetten en kort inschakelen Van bovenaf gezien schokt de pomp bij de juiste draairichting...

Page 40: ...mineerd De verpakking moet het product beschermen tegen beschadigingen Raadpleeg de fabrikant voorafgaand aan het retourneren 4 Verpakking transport en opslag 4 1 Aanlevering Na ontvangst moet de zend...

Page 41: ...mdat een ondichtheid de pompcapaciteit van de pomp vermindert De pomp met kabel of ketting aan de handgreep bevesti gen en daaraan in de vloeistof laten zakken Bij modderige ondergrond stenen o i d on...

Page 42: ...eidsinrichtingen en noodstop schakelingen v r de inbedrijfstelling Elektrotechnische en mechanische instellingen mo gen alleen door vakkrachten worden uitgevoerd Deze machine is alleen geschikt voor t...

Page 43: ...rden af gevoerd volgens richtlijn 75 439 EEG en verordenin gen 5a 5b volgens AbfallGesetz Duitse afvalwet Bij reinigings en onderhoudswerkzaamheden moet de juiste beschermende kleding worden gedragen...

Page 44: ...ngen Schroefborgingen zoals veerringen moeten altijd worden vervangen De aanhaalmomenten moeten worden aangehoud en Algemeen geldt bij reparatiewerkzaamheden Machine uitschakelen loskoppelen van het s...

Page 45: ...en en werkzaamheden worden uitgevoerd zie hoofdstuk On derhoud De correcte toestand en de werking van de gli jringafdichting moet worden gecontroleerd Na afronding van deze werkzaamheden kan de machin...

Page 46: ...zich aan flexibele bodem vast Plaats de pomp op een stevige vlakke ondergrond Machine draait maar de opgegeven bedrijfswaarden worden niet aangehouden Oorzaak Oplossing Toevoer verstopt Toevoerleidin...

Page 47: ...Nedlerlands 47 Notizen Notes...

Page 48: ...dingte Kontaminierung des Ger tes toxisch nein ja welche Stoffe tzend nein ja welche Stoffe mikrobiologisch nein ja welche Stoffe explosiv nein ja welche Stoffe radioaktiv nein ja welche Stoffe sonsti...

Page 49: ...the instruments toxic no yes substance corrosive no yes substance microbiological no yes substance explosive no yes substance radioactive no yes substance other substances no yes substance Legally bin...

Page 50: ...tourneren Contaminatie van het apparaat als gevolg van de toepassing giftig nee ja welke stoffen bijtend nee ja welke stoffen microbiologisch nee ja welke stoffen explosief nee ja welke stoffen radioa...

Page 51: ...our other household waste You are liable to dispose of all your electronic or electrical waste equipment by relocating over to the specified collection point for recycling of such hazardous waste Isol...

Page 52: ...x 49 0 2247 702 44 e Mail info homa pumpen de Internet www homa pumpen de Industriestra e 1 53819 Neunkirchen Seelscheid Telefon 49 0 2247 702 0 Fax 49 0 2247 702 44 e Mail info homa pumpen de Interne...

Reviews: