ASSEMBLY
HOLZMANN MASCHINEN GmbH www.holzmann-maschinen.at
27
TK 255
15.5
Power supply
A T T E N T I O N
When working with non-grounded machines:
Severe injury or even death may arise though electrocution!
Therefore
: The machine must be operated at a grounded power socket
The connection of the machine to the electric power supply and the following checks have to be
carried out by a respectively trained electrician only.
1.
The electronic connection of the machine is designated for operation with a grounded power
socket!
2.
The mains supply must be secured with 16A:
3.
If the connector plug doesn’t fit or if it is defect, only qualified electricians may modify or
re-new it!
4.
Check, whether the feeding voltage and the Hz comply to the required values of the
machine. A deviation of feeding voltage of ±5% is allowed
5.
Make sure that a possible extension cord is in good condition and suitable for the
transmission of power. An undersized cord reduces the transmission of power and heats up.
6.
A damaged cable must be replaced immediately
N O T I C E
Operation is only allowed with safety switch against stray
current (RCD max. stray current of 30mA)
N O T I C E
Use only permitted extension cable with cross-section
the one in the following table declared.
Voltage
Extension
Cross-section
220 V-240 V
50 Hz
<27 m
1,5 mm
2
<44 m
2,5 mm
2
<70 m
4,0 mm
2
<105 m
6,0 mm
2
Summary of Contents for TK 255
Page 6: ...ILLUSTRATION HOLZMANN MASCHINEN GmbH www holzmann maschinen at 6 TK 255 3 ILLUSTRATION...
Page 7: ...ILLUSTRATION HOLZMANN MASCHINEN GmbH www holzmann maschinen at 7 TK 255...
Page 8: ...ILLUSTRATION HOLZMANN MASCHINEN GmbH www holzmann maschinen at 8 TK 255...
Page 9: ...ILLUSTRATION HOLZMANN MASCHINEN GmbH www holzmann maschinen at 9 TK 255...
Page 42: ......