For technical questions, please call 1-888-866-5797.

Item 57056 

        

Sa
FE
ty

Op
E

ra
ti

O

n

Maint

E

nanc

E

S

E

tup

air Source

1. 

 

never connect to an air source  

 

that is capable of exceeding  

 

200 psi.

  Over pressurizing the  

 

tool may cause bursting, abnormal  

 

operation, breakage of the tool or 

serious injury to persons.  Use only clean, dry, 
regulated compressed air at the rated pressure 
or within the rated pressure range as marked on 
the tool.  Always verify prior to using the tool that 
the air source has been adjusted to the rated air 
pressure or within the rated air-pressure range.

2. 

Never use oxygen, carbon dioxide, combustible 
gases or any bottled gas as an air source 
for the tool.

  Such gases are capable of 

explosion and serious injury to persons.

Vibration precautions

This tool vibrates during use.  Repeated or 
long-term exposure to vibration may cause 
temporary or permanent physical injury, 
particularly to the hands, arms and shoulders.  
To reduce the risk of vibration-related injury:

1.  Anyone using vibrating tools regularly or for 

an extended period should first be examined 
by a doctor and then have regular medical 
check-ups to ensure medical problems are not 
being caused or worsened from use.  Pregnant 
women or people who have impaired blood 
circulation to the hand, past hand injuries, 
nervous system disorders, diabetes, or Raynaud’s 
Disease should not use this tool.  If you feel 
any symptoms related to vibration (such as 
tingling, numbness, and white or blue fingers), 
seek medical advice as soon as possible.

2.  Do not smoke during use.  Nicotine reduces 

the blood supply to the hands and fingers, 
increasing the risk of vibration-related injury.

3.  Wear suitable gloves to reduce the 

vibration effects on the user.

4.  Use tools with the lowest vibration 

when there is a choice.

5.  Include vibration-free periods each day of work.

6.  Grip tool as lightly as possible (while still keeping 

safe control of it).  Let the tool do the work.

7.  To reduce vibration, maintain 

tool as explained in this manual.  
If abnormal vibration occurs, stop immediately.

 SaVE tHESE inStructiOnS.

Summary of Contents for 57056

Page 1: ...ence 20d When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2020 by Harbor Freight Tools All...

Page 2: ...iMpOrtant SaFEty inStructiOnS read all safety warnings and instructions Failure to follow the warnings and instructions may result in serious injury Work area 1 Keep the work area clean and well lit...

Page 3: ...ross contamination use a different Fluid Extractor for each purpose 6 Do not throw drop or mishandle this product 7 Industrial applications must follow OSHA requirements 8 This product is not a toy Do...

Page 4: ...ers To reduce the risk of vibration related injury 1 Anyone using vibrating tools regularly or for an extended period should first be examined by a doctor and then have regular medical check ups to en...

Page 5: ...cFM Cubic Feet per Minute flow at standard conditions npt National pipe thread tapered npS National pipe thread straight WARNING marking concerning Risk of Eye Injury Wear ANSI approved eye protection...

Page 6: ...iption Specifications Working Air Pressure 60 150 PSI Air Inlet 1 4 NPT Air Consumption 0 30 CFM 90 PSI Vacuum 24 inHg 90 PSI Reservoir Tank Capacity 2 3 Gal components and controls Fluid Coupler Spou...

Page 7: ...uS inJury FrOM acciDEntaL OpEratiOn Do not install a female quick coupler on the tool Such a coupler contains an air valve that will allow the air tool to retain pressure and operate accidentally afte...

Page 8: ...r Hose Connects air to tool B Filter Prevents dirt and condensation from damaging tool or workpiece C Regulator Adjusts air pressure to tool D Lubricator optional For air tool lubrication E Coupler an...

Page 9: ...bration reduction E Main Air Line 3 4 minimum recommended Distributes air to branch lines F Ball Valve To drain moisture from system G Branch Air Line 1 2 minimum recommended Brings air to point of us...

Page 10: ...mission until it reaches the bottom of the transmission pan nOtE Do not bend the Extracting Tube when inserting Narrower dipstick tubes may prevent insertion of the Extracting Tubes 4 Insert the adapt...

Page 11: ...Spout Pour the collected fluid into an appropriate container and dispose of in accordance with all applicable local state and federal laws Do not store fluid in the Reservoir Tank 10 Clean external s...

Page 12: ...completely then store in a safe dry clean location out of reach of children Do not allow solvent to sit in Reservoir Tank for an extended period Engine coolant Extraction 1 Loosen the vehicle s radiat...

Page 13: ...broken parts any other condition that may affect its safe operation 2 Daily air Supply Maintenance Every day maintain the air supply according to the component manufacturers instructions Drain the mo...

Page 14: ...serial number record month and year of purchase instead note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts part Description Qt...

Page 15: ...questions please call 1 888 866 5797 Item 57056 SaFEty OpEratiOn MaintEnancE SEtup assembly Diagram 7 5 4 3 18 8 9 20 19 21 22 23 24 14 13 12 17 11 6 15 16 25 30 28 27 29 10 31 32 26 33 34 35 2 1 40 4...

Page 16: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...

Reviews: