background image

Page 8

TYPE 

1.1.0.10-RF

VIO RAVA Quick Start

1.  Plug the device into the network. Device will speak it’s IP address.

2.  Navigate to device IP on a web browser.

3.  Under “Configuration” please enter SIP ID for the name to be displayed, and enter the extension

of the Main RAVA Touchscreenunder “

Input Call ID 0 Default is CALL:CRESTRON”

*Note out of the box the “CALL:CRESTRON” default will ring all touchpanels in the CRESTRON

call group.  

4.  Configure the Audio setiings. 

Note:RAVA Operation has been designated to “Push to Talk” (PTT)

from Crestron and only this operation will be supported.

Although full duplex and half duplex

are an option, these settingdo not perform best in all senarios. As a recommendation you can 

experiment for the best audio settings.

AUDIO SETTING BELOW ARE ONLY A RECOMMENDATION

Summary of Contents for 101-VIO2

Page 1: ...supply included Internal rectifier gives optional dc out for strikes For Models 101 VIO2 107 VIO2 Communication Holovision VIO2 is a SIP enabled intercom module developed specifically with the custom...

Page 2: ...1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l AC Out for Strike DC out for strike 16 5 VAC MOV is recommended Gate Strike NOTE Jumper Wire is...

Page 3: ...Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l The 265 module comes with jumpers and MOVs prewired to the l...

Page 4: ...ch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes o o o...

Page 5: ...is pressed you have 2 minutes to complete Step 5 3 Press 1119 you will hear 3 beeps 4 Step 5 must be completed within 5 seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm ne...

Page 6: ...for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits Page 6 TYPE 1 1 0 10 RF 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the jumper...

Page 7: ...1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5 seconds for 4 reset beeps Set Activation Time Of Relay 2 User codes 3 4 5 see note below Step Action Note The above 2 steps are actually setting the act...

Page 8: ...ll ID 0 Default is CALL CRESTRON Note out of the box the CALL CRESTRON default will ring all touchpanels in the CRESTRON call group 4 Configure the Audio setiings Note RAVA Operation has been designat...

Page 9: ...Calls Configure the powered relay and the dry contact closure Choose any 2 to 4 digit combination Note By configuring the request to exit feature you can configure for either relay 6 Once the device h...

Page 10: ...Page 10 TYPE 1 1 0 10 RF...

Page 11: ...Page 11 TYPE 1 1 0 10 RF...

Page 12: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Reviews: