background image

Programming of Essex Keypad

        1            Press “Program” switch (keypad will beep 4 times).

        2            Enter 1115 (3 beeps).

        3            Enter 1 for every 1 second  latch time, and 5 for every 5 seconds.

                      Examples:

                      

6 seconds = 5, 1

                      

8 seconds = 5, 1, 1, 1

                      

12 seconds = 5, 5, 1, 1

        4            Wait 5 seconds for 4 reset beeps.

Set Activation Time Of Relay 2 (User codes 3, 4& 5 - see note below)

  Step                                                     Action

Note: The above 2 steps are actually setting the activation times for user code 1, 2 and user code 3, 4, 5.  Using the

jumper pin setting as shown in “Set Essex Relay Options”, this will set activation time of Relays 1 & 2.

Page 7

TYPE 

1.1.0.10-RF

Summary of Contents for 101-VIO2

Page 1: ...supply included Internal rectifier gives optional dc out for strikes For Models 101 VIO2 107 VIO2 Communication Holovision VIO2 is a SIP enabled intercom module developed specifically with the custom...

Page 2: ...1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l AC Out for Strike DC out for strike 16 5 VAC MOV is recommended Gate Strike NOTE Jumper Wire is...

Page 3: ...Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l The 265 module comes with jumpers and MOVs prewired to the l...

Page 4: ...ch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes o o o...

Page 5: ...is pressed you have 2 minutes to complete Step 5 3 Press 1119 you will hear 3 beeps 4 Step 5 must be completed within 5 seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm ne...

Page 6: ...for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits Page 6 TYPE 1 1 0 10 RF 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the jumper...

Page 7: ...1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5 seconds for 4 reset beeps Set Activation Time Of Relay 2 User codes 3 4 5 see note below Step Action Note The above 2 steps are actually setting the act...

Page 8: ...ll ID 0 Default is CALL CRESTRON Note out of the box the CALL CRESTRON default will ring all touchpanels in the CRESTRON call group 4 Configure the Audio setiings Note RAVA Operation has been designat...

Page 9: ...Calls Configure the powered relay and the dry contact closure Choose any 2 to 4 digit combination Note By configuring the request to exit feature you can configure for either relay 6 Once the device h...

Page 10: ...Page 10 TYPE 1 1 0 10 RF...

Page 11: ...Page 11 TYPE 1 1 0 10 RF...

Page 12: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Reviews: