Set Essex Relay Options

  Step                                                     Action

GOAL:

To use jumper pins on circuit board to configure standard

relay options.  In this configuration, Codes 1 and 2 

operate Relay 1.   Codes 3, 4, 5 operate Relay 2.

1          Relay 1 and 2 activate.  Only Relay 1 latch* 

Code

Relay 1                Relay 2 

Open        Latch       Open         Latch

Master Code       No       No             No           No

Code 1,2            Yes      Yes            No            No

Code 3, 4, 5        No       No            Yes          No  

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

Master Unlock

1, 2 Unlock

3,4,5 Unlock

1,2  Latch

3, 4,5 Latch

CCTV

Doorbell

Relay 1

Relay 2

  Step                                                     Action

2          Relay 1 and 2 activate and latch* 

Code

Relay 1                Relay 2 

Open        Latch       Open         Latch

Master Code       No       No             No           No

Code 1,2            Yes      Yes            No            No

Code 3, 4, 5        No       No            Yes          Yes  

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

o

Master Unlock

1, 2 Unlock

3,4,5 Unlock

1,2  Latch

3, 4,5 Latch

CCTV

Doorbell

Relay 1

Relay 2

*LATCHING RELAY:

In order to latch either relay, simply enter the code,

followed by “7”.    Repeat (code, 7) in order to unlatch the relay.

The top example would be used where the driveway gate was connected to

Relay 1 (and could be locked open), and the pedestrian gate was connected

to Relay 2. (No latching possible).

Page 4

TYPE 

1.1.0.10-RF

Summary of Contents for 101-VIO2

Page 1: ...supply included Internal rectifier gives optional dc out for strikes For Models 101 VIO2 107 VIO2 Communication Holovision VIO2 is a SIP enabled intercom module developed specifically with the custom...

Page 2: ...1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l AC Out for Strike DC out for strike 16 5 VAC MOV is recommended Gate Strike NOTE Jumper Wire is...

Page 3: ...Essex Model 265 NC 2 NO 2 COM 2 NC 1 NO 1 COM 1 DC OUT AC IN Remote Monitor Earth Holovision Entry System with Keypad Keypad cable 22 12 l The 265 module comes with jumpers and MOVs prewired to the l...

Page 4: ...ch CCTV Doorbell Relay 1 Relay 2 Step Action 2 Relay 1 and 2 activate and latch Code Relay 1 Relay 2 Open Latch Open Latch Master Code No No No No Code 1 2 Yes Yes No No Code 3 4 5 No No Yes Yes o o o...

Page 5: ...is pressed you have 2 minutes to complete Step 5 3 Press 1119 you will hear 3 beeps 4 Step 5 must be completed within 5 seconds of Step 3 5 Enter Master Code 6 Wait 5 seconds for 3 beeps to confirm ne...

Page 6: ...for 3 reset beeps Delete Any Code Step Action Note User codes can be 3 to 8 digits Page 6 TYPE 1 1 0 10 RF 1 Enter any User Code 1 5 2 Enter 7 This will cause the relay to latch subject to the jumper...

Page 7: ...1 8 seconds 5 1 1 1 12 seconds 5 5 1 1 4 Wait 5 seconds for 4 reset beeps Set Activation Time Of Relay 2 User codes 3 4 5 see note below Step Action Note The above 2 steps are actually setting the act...

Page 8: ...ll ID 0 Default is CALL CRESTRON Note out of the box the CALL CRESTRON default will ring all touchpanels in the CRESTRON call group 4 Configure the Audio setiings Note RAVA Operation has been designat...

Page 9: ...Calls Configure the powered relay and the dry contact closure Choose any 2 to 4 digit combination Note By configuring the request to exit feature you can configure for either relay 6 Once the device h...

Page 10: ...Page 10 TYPE 1 1 0 10 RF...

Page 11: ...Page 11 TYPE 1 1 0 10 RF...

Page 12: ...501 E Goetz Ave Santa Ana Ca 92707 Ph 714 434 6904 Fax 800 362 0002 www eholovision com...

Reviews: