HOLOPHANE Predator LED Flood Medium Installation And Maintenance Manual Download Page 5

 

 

 

IM-365-A 

 

Replacement of any electrical components (with the exception of the 
photocontrol) requires entry into the housing to access them. Assure 
that power has been shut off before attempting to open the door.   
 
The door is sealed with a one-piece silicone gasket. Take precaution 
while opening the door not to damage or disturb the gasket.   
 
The access door to your luminaire is normally fastened to the housing 
with captive socket head cap screws; however, your luminaire may be 
equipped with over-center latches for tool-less access. The door also 
has twin pivot hinges to hold the door to the housing. Take precaution 
when opening the door. Support the weight of the door while lowering, 
taking care not to let the door impact any surrounding object or 
surface. The door can be removed if necessary. 
 

3.2.1 

Disconnect power to the unit prior to opening and performing 

any maintenance

.

 

3.2.2 

Access to the LED modules should be performed by qualified 

personnel experienced with solid state lighting only.  Contact factory 
for support. 

 

3.2.3 

Loosen closure screws or disengage latches. Carefully open 

electrical housing. See Figure 4.

 

3.2.4 

Surge Protector Replacement:  See Figure 4.  Locate the surge 

protectors.  Disconnect the surge protector via the wiring quick 
disconnects.  Loosen the clamp band holding the surge protectors in 
place.  Carefully remove the surge protectors and install the new, 
Holophane approved surge protectors in the same orientation with the 
original screw and wire tie.  Re-connect the surge protectors’ quick 
disconnects.  Close the door and secure door closure screws or 
latches. Tighten evenly and securely.  Perform step 2.3.7. 

3.2.5 

LED Driver Replacement:  Before removing components, 

disconnect driver input and output leads nearest the driver via the 
wiring quick disconnects.  Remove the (4) driver screws to remove the 
driver from the electrical door; retain screws for reuse.  Install new 
Holophane approved driver and tighten screws securely.  Reconnect 
all driver input and output leads.  Close the door and secure door 
closure screws or latches. Tighten evenly and securely.  Perform step 
2.3.7. 

3.2.6 

Door Replacement:  Loosen closure screws or disengage 

latches. Carefully open electrical housing. Disconnect the driver input 
and output quick disconnect harnesses and disengage the hinge from 
the door via key slot by depressing the spring clip on both sides. See 
Figure 4. Replace with new Holophane supplied door assembly. Close 
the door and secure door closure screws or latches. Tighten evenly 
and securely. Perform step 2.3.7. 
 

CAUTION 

BE CERTAIN THAT NO WIRING IS PINCHED BETWEEN 
THE DOOR AND HOUSING OR BETWEEN THE DOOR AND 
REFLECTOR. 

 

WARRANTY 

Five-year limited warranty. Full warranty terms located at 
http://www.acuitybrands.com/customerresources/terms_and_condition
s.aspx 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                          

Reviews: