IM-365-A
Replacement of any electrical components (with the exception of the
photocontrol) requires entry into the housing to access them. Assure
that power has been shut off before attempting to open the door.
The door is sealed with a one-piece silicone gasket. Take precaution
while opening the door not to damage or disturb the gasket.
The access door to your luminaire is normally fastened to the housing
with captive socket head cap screws; however, your luminaire may be
equipped with over-center latches for tool-less access. The door also
has twin pivot hinges to hold the door to the housing. Take precaution
when opening the door. Support the weight of the door while lowering,
taking care not to let the door impact any surrounding object or
surface. The door can be removed if necessary.
3.2.1
Disconnect power to the unit prior to opening and performing
any maintenance
.
3.2.2
Access to the LED modules should be performed by qualified
personnel experienced with solid state lighting only. Contact factory
for support.
3.2.3
Loosen closure screws or disengage latches. Carefully open
electrical housing. See Figure 4.
3.2.4
Surge Protector Replacement: See Figure 4. Locate the surge
protectors. Disconnect the surge protector via the wiring quick
disconnects. Loosen the clamp band holding the surge protectors in
place. Carefully remove the surge protectors and install the new,
Holophane approved surge protectors in the same orientation with the
original screw and wire tie. Re-connect the surge protectors’ quick
disconnects. Close the door and secure door closure screws or
latches. Tighten evenly and securely. Perform step 2.3.7.
3.2.5
LED Driver Replacement: Before removing components,
disconnect driver input and output leads nearest the driver via the
wiring quick disconnects. Remove the (4) driver screws to remove the
driver from the electrical door; retain screws for reuse. Install new
Holophane approved driver and tighten screws securely. Reconnect
all driver input and output leads. Close the door and secure door
closure screws or latches. Tighten evenly and securely. Perform step
2.3.7.
3.2.6
Door Replacement: Loosen closure screws or disengage
latches. Carefully open electrical housing. Disconnect the driver input
and output quick disconnect harnesses and disengage the hinge from
the door via key slot by depressing the spring clip on both sides. See
Figure 4. Replace with new Holophane supplied door assembly. Close
the door and secure door closure screws or latches. Tighten evenly
and securely. Perform step 2.3.7.
CAUTION
BE CERTAIN THAT NO WIRING IS PINCHED BETWEEN
THE DOOR AND HOUSING OR BETWEEN THE DOOR AND
REFLECTOR.
4
WARRANTY
Five-year limited warranty. Full warranty terms located at
http://www.acuitybrands.com/customerresources/terms_and_condition
s.aspx