HOLOPHANE Predator LED Flood Medium Installation And Maintenance Manual Download Page 3

HOLOPHANE

®

 

Predator

®

 LED Flood 

Installation and 

 

Large and Medium 

Maintenance 

 

 

Manual 

 

 

IM-365-A 

 

 

 

 

 GR2279 

 

INTRODUCTION 
 

1.1

 

Product Description 

The Predator

®

 LED Flood luminaire has been listed to applicable U.S. 

& Canadian safety standards by Underwriters Laboratories Inc. It is 
suitable for use in wet locations and ambient temperatures up to 40°C. 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: (1) this device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation.

 

 

The LED driver/door assembly can be detached for repair by 
disengaging the hinge and unplugging electrical connectors. See 
Figure 4. 

 

1.2  Alternate Information Sources. 

If additional questions 

arise relative to these luminaires that this document or your supplier 
cannot answer, please refer them to: 
 

Holophane 

Field Service Department 

P.O. Box 3004 

Newark, OH  43058-3004 

(740) 345-9631 

 

INSTALLATION 

 

2.1  Tools and Materials Required.  

DESCRIPTION 

USE 

9/16” Hex Wrench 

Knuckle fitter bolt and set screws,  

 

 3/8-16UNC Yoke bolt 

3/4” Hex Wrench 

1/2-18UNC Yoke bolt 

7/8” Hex Wrench 

Yoke nut 

1/4” Nut Driver 

Knuckle Fitter Wiring Cover 

3/16” Allen Wrench 

Closure Screws (Not needed for TL option) 

Torque Wrench (ft.-lbs.) 

Mounting Bolts, Knuckle fitter bolt and set 
screws 

Figure 1 

 

GR2276 

 
Figure 2 

 

GR2280 

 
 

2.2  Yoke Mount Installation. 

This luminaire is pre-wired with a UL listed wet location power cord and 
fittings, so it is not necessary to open the housing door to install or wire 
the luminaire. If access to the interior of the housing is necessary, refer 
to the MAINTENANCE section (SECTION 3) below. 

2.2.1 

Bolt the yoke to the mounting structure using either two 3/8" 

bolts or one 3/4" grade 5 bolt. Tighten bolts securely (30-35 ft.-lbs. for 
3/8" bolts or 190-200 ft.-lbs. for 3/4" bolt). The bolts and other 
hardware are not provided.  See Figure 2 for mounting hole pattern. 

2.2.2 

Make all wiring connections in accordance with approved 

wiring methods. 