HOLOPHANE Phuzion PHZL Installation And Maintenance Manual Download Page 1

 

LED IMPORTANT SAFETY INSTRUCTIONS 

 

 

 
 
 
 
 

 

To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and 
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.   

 

Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions. 

 

Installation and service of luminaires should be performed by a 

qualified licensed electrician

.  

 

Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation 
and any hazards involved.  Regular fixture maintenance programs are recommended.  

 

It will occasionally be necessary to clean the outside of the refractor/lens.  Frequency of cleaning will depend on ambient 
dirt level and minimum light output which is acceptable to user.  Refractor/lens should be washed in a solution of warm 
water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.  Should optical assembly 
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.  

 

DO NOT INSTALL DAMAGED PRODUCT!  

This luminaire has been properly packed so that no parts should have been 

damaged during transit. Inspect to confirm.  Any part damaged or broken during or after assembly should be replaced.

 

 

Recycle: For information on how to recycle LED electronic products, please visit 

www.epa.gov

.     

 

These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency 
to meet in connection with installation, operation, or maintenance.  Should further information be desired or should 
particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be 
referred to Acuity Brands Lighting, Inc.  
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! 

SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION 

 

 

Disconnect or turn off power before 
installation or servicing. 

 

Verify that supply voltage is correct by 
comparing it with the luminaire label 
information. 

 

Make all electrical and grounded 
connections in accordance with the National 
Electrical Code (NEC) and any applicable 
local code requirements. 

 

All wiring connections should be capped 
with UL approved recognized wire 
connectors. 

 
 
 

 

 

WARNING 

RISK OF ELECTRIC SHOCK 

 

 

 

 

Allow lamp/fixture to cool before handling. 
Do not touch enclosure or light source. 

 

Follow all manufacturer’s warnings, 
recommendations and restrictions for: driver 
type, burning position, mounting 
locations/methods, replacement and 
recycling.    
 

 
 
 

 

 

WARNING 

RISK OF BURN 

 

 

 

 

Wear gloves and safety glasses at all times 
when removing luminaire from carton, 
installing, servicing or performing 
maintenance. 

 

Avoid direct eye exposure to the light source 
while it is on. 
 
 

 
 
 

 

 

CAUTION 

RISK OF INJURY 

 

 

 

Keep combustible and other materials that 
can burn, away from lamp/lens.   

 

Do not operate in close proximity to 
persons, combustible materials or 
substances affected by heat or drying.  
 

 
 
 

 

 

CAUTION 

RISK OF FIRE 

Summary of Contents for Phuzion PHZL

Page 1: ...ic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation...

Page 2: ...ndividual product specifications deem otherwise Never connect an LED product directly to a dimmer packs occupancy sensors timing devices or other related control devices LED fixtures must be powered d...

Page 3: ...or Stem Set Screw 3 8 socket Electrical housing surface mount 2 2 Stem to Optical Housing Installation Figure 2 3 2 2 1 Ensure the ground wire and all 3 sets of input leads are present and accessible...

Page 4: ...al Housing by placing the stem fitting onto the hook bracket and install cotter pin 2 3 6 Route leads from mounting stem into the outlet box 2 3 7 Slide cover and swivel dome up stem Secure swivel dom...

Page 5: ...GAGE MAX LENGTH FEET 18 AWG 70 16 AWG 120 14 AWG larger 150 CAUTION MOUNT ELECTRICAL HOUSING 4 FEET AWAY HORIZONTALLY FROM THE OPTICAL HOUSING TO ENSURE ELECTRICAL COMPONENTS DO NOT EXCEED THEIR MAX...

Page 6: ...2 6 3 Mount Electrical Housing using fasteners properly sized to support the weight of the Electrical Housing fasteners not provided Figure 6 GR2435 2 10 Safety Chain Option 2 10 1 Safety chain optio...

Page 7: ...ready labeled 3 1 4 Replace components using Holophane approved replacement parts 3 1 5 Re connect electrical leads 3 1 6 Shut electrical door and tighten door screws ensuring all leads are completely...

Reviews: