RESIDUAL RISKS
In following the relevant safety regulations and the implementation of safety
devices, certain residual risks cannot be avoided.
These are:
•
Impairment of hearing
•
Risk of personal injury from flying particles
•
Risk of burns due to accessories becoming hot during operation
•
Risk of personal injury due to prolonged use.
Always try to reduce these risks further by the use safe working practices and the use of appropriate
PPE as much as possible.
3
Description
3.1
Intended use
This magnetic drilling machine is intended for commercial/industrial use as a magnetic base drilling
machine for drilling materials with a magnetizable surface using annular cutters and twist drills.
The magnetic drilling machine can be used horizontally, vertically or overhead using the safety strap
provided, taking the precautions identified in this manual.
This magnetic drilling machine is IP20 and is intended to be used in a weather-protected
environment. Ambient operating temperatures of <-10 and >45
°
C should be avoided.
Use only HMT approved tools and accessories with this machine.
The machine should not be used beyond its stated capacities.
The machine should not be used for any purpose other than stated.
The machine should NEVER be used without a protective earth or ground connection.
The machine SHOULD NOT be used in a potentially explosive environment.
The machine should not be used as a lifting device, the magnetic base is for clamping only.