HOKUTO DENSHI
CO;LTD;
FLASH2
株式会社
3
Specifications
MCU available:
Renesas Electronics’s
Flash memory MCU
of single power supply
and Expanded
memory of
H8SX/1650 and H8SX/1651.
See the available type name list at the end.
* MCU that appears in this document is the flash memory edition.( H8SX/1650, H8SX/1651 group is
excluded.)
PC interface:
RS232C-serial-port (the straight cable is required for the connection.)
The DUSB 25 pins socket is equipped as the programmer
’
s PC interface connector.
See the note in the
“
User
’
s Guide
”
about the connection in the straight cable.
Power Supply:
AC adapter (DC9V) or 2 alkaline drycells (LR6/1.5 volt)
The provided AC adapter is verified for Japanese domestic use only.
Specifications of AC adapter
Input
Voltage
:
AC100
~
240V
Frequency
:
50
~
60Hz Input current
:
Under 300mA
Output
Voltage
:
DC9V
Maximum output current
:
1.33A
Jack
Form
:
Center-minus
Dimension
:
Outside diameter
φ
5.5mm /Inside diameter
φ
2.1mm
In use with drycells, we recommend to exchange the drycells in every 1 hour for successively programming.
Programming Voltage: 5V or 3.3V
(depend on
“VIN”, that is target Vcc power supply to Interface 18,20pin)
PC available:
F2WinV2
:
WindowsXP, Vista, 7, 8.1 and 10
Japanese version
- Some types are not available -
(Windows95, 98, Me, NT, 2000: Not supported.(*1))
Body Case Size:
96 mm
×
145 mm
×
35 mm
(89 mm
×
134 mm
×
36 mm, *~Sep/2017, old case size)
Weight:
180g (without drycells)
Operating conditions
Programmer Operating Temperature
0
℃~
+40
℃
,
less than 80
%
RH without bedewing
*Confirmed Operating Temperature with
AC
adapter -10
℃~
+50
℃
with drycells
+10
℃~
+50
℃
depends on the cell spec
AC adapter Operating Temperature
0
℃~
+40
℃
Storage Temperature
-25
℃~
+60
℃
,
less than 80
%
RH without bedewing
Package Seal and Products Serial Number
Package
Sealed
Product Serial
Upside of the box, Back side of the Programmer body,
Inside of the drycell box,
And On the Enclosed CD
(*1)
When using with Windows 95, 98, Me
Copy F2WinV2.exe in "Japanese/for_Windows95_98_Me" to PC storage and execute.
As of 2020/2, it is difficult to maintain an old OS machine for verification, so we will remove it from
support.
FLASH2