Operation 9
HP-210
2
Operation
2.1
Principle
The Hoffer MF Series has been developed to meet the need for a
low flow measurement device for use with low to moderate
viscosity clean liquids and for gas measurement applications.
The MF Series is a family of low flow rate measurement devices
whose design is based on a Pelton Wheel-like rotor. The measured
fluid is directed tangentially through a velocity nozzle against the
rotor causing it to spin. The pickup coil senses the spinning
motion of the rotor through the housing and converts it into a
pulsing electrical signal. Summation of the pulsing electrical
signal relates directly to the total flow, while the frequency is
related to the flow rate.
2.2
Precautions
Do not drop the meter. Dropping the meter may result in damage
to the meter housing and/or internals.
Do not operate the meter at flowrates greater than the maximum
flowrate marked on the meter. Operating at flowrates greater than
the maximum flowrate may over-spin the meter. Over-spinning
may result in damage to the meter.
CAUTION
:
Avoid over-spinning the meter. Over-spinning the meter may
result in damage to the meter internals and lead to meter
failure.